Loïc Boussel

Dr. Loïc Boussel


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 December 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SSSalim Aymeric Si-Mohamed
Salim Aymeric Si-Mohamed
JMJade Miailhes
Jade Miailhes
PRPierre-Antoine Rodesch
Pierre-Antoine Rodesch
SBSara Boccalini
Sara Boccalini
HLHugo Lacombe
Hugo Lacombe
PDPhilippe Douek
Philippe Douek
The X-ray imaging field is currently undergoing a period of rapid technological innovation in diagnostic imaging equipment. An important recent development is the advent of new X-ray detectors, i.e., photon-counting detectors (PCD), which have been introduced in recent clinical prototype systems, called PCD computed tomography (PCD-CT) or photon-counting CT (PCCT) or spectral photon-counting CT (SPCCT) systems. PCD allows a pixel up to 200 microns pixels at iso-center, which is much smaller than that can be obtained with conventional energy integrating detectors (EID). PCDs have also a higher dose efficiency than EID mainly because of electronic noise suppression. In addition, the energy-resolving capabilities of these detectors allow generating spectral basis imaging, such as the mono-energetic images or the water/iodine material images as well as the K-edge imaging of a contrast agent based on atoms of high atomic number. In recent years, studies have therefore been conducted to determine the potential of PCD-CT as an alternative to conventional CT for chest imaging.

16 December 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
David C. RotzingerDavid C. Rotzinger
David C. Rotzinger
DRDamien Racine
Damien Racine
Fabio BecceFabio Becce
Fabio Becce
ELElias Lahoud
Elias Lahoud
KEKlaus Erhard
Klaus Erhard
PDPhilippe C. Douek
Philippe C. Douek
Aims: To evaluate spectral photon-counting CT’s (SPCCT) objective image quality characteristics in vitro, compared with standard-of-care energy-integrating-detector (EID) CT. Methods: We scanned a thorax phantom with a coronary artery module at 10 mGy on a prototype SPCCT and a clinical dual-layer EID-CT under various conditions of simulated patient size (small, medium, and large). We used filtered back-projection with a soft-tissue kernel. We assessed noise and contrast-dependent spatial resolution with noise power spectra (NPS) and target transfer functions (TTF), respectively. Detectability indices (d’) of simulated non-calcified and lipid-rich atherosclerotic plaques were computed using the non-pre-whitening with eye filter model observer. Results: SPCCT provided lower noise magnitude (9–38% lower NPS amplitude) and higher noise frequency peaks (sharper noise texture). Furthermore, SPCCT provided consistently higher spatial resolution (30–33% better TTF10). In the detectability analysis, SPCCT outperformed EID-CT in all investigated conditions, providing superior d’. SPCCT reached almost perfect detectability (AUC ≈ 95%) for simulated 0.5-mm-thick non-calcified plaques (for large-sized patients), whereas EID-CT had lower d’ (AUC ≈ 75%). For lipid-rich atherosclerotic plaques, SPCCT achieved 85% AUC vs. 77.5% with EID-CT. Conclusions: SPCCT outperformed EID-CT in detecting simulated coronary atherosclerosis and might enhance diagnostic accuracy by providing lower noise magnitude, markedly improved spatial resolution, and superior lipid core detectability.

1 March 2019 in Diagnostic and Interventional Imaging
Verified
Journal Article
Closed access
MCM. Colevray
M. Colevray
VTVm. Tatard-Leitman
Vm. Tatard-Leitman
SGS. Gouttard
S. Gouttard
PDP. Douek
P. Douek
LBLoïc Boussel
Loïc Boussel

1 November 2015 in European Journal of Radiology
Verified
Journal Article
Closed access
TBThomas Brunel
Thomas Brunel
AGAymeric Guibal
Aymeric Guibal
CBCamille Boularan
Camille Boularan
CDChristian Ducerf
Christian Ducerf
JMJean-Yves Mabrut
Jean-Yves Mabrut
ARAgnès Rode
Agnès Rode

Verified
Journal Article
Open access
PDF file
SSSalim Aymeric Si-Mohamed
Salim Aymeric Si-Mohamed
LRLauria Marie Restier
Lauria Marie Restier
ABArthur Branchu
Arthur Branchu
SBSara Boccalini
Sara Boccalini
ACAnaelle Congi
Anaelle Congi
PDPhilippe Charles Douek
Philippe Charles Douek
Background: Myocardial extracellular volume (ECV) is a marker of the myocarditis inflammation burden and can be used for acute myocarditis diagnosis. Dual-energy computed tomography (DECT) enables its quantification with high concordance with cardiac magnetic resonance (CMR). Purpose: To investigate the diagnostic performance of myocardial ECV quantified on a cardiac dual-layer DECT in a population of patients with suspected myocarditis, in comparison to CMR. Methods: 78 patients were included in this retrospective monocenter study, 60 were diagnosed with acute myocarditis and 18 patients were considered as a control population, based on the 2009 Lake and Louise criteria. All subjects underwent a cardiac DECT in acute phase consisted in an arterial phase followed by a late iodine enhancement phase at 10 min after injection (1.2 mL/kg, iodinated contrast agent). ECV was calculated using the hematocrit level measured the day of DECT examinations. Non-parametric analyses have been used to test the differences between groups and the correlations between the variables. A ROC curve has been used to identify the optimal ECV cut-off discriminating value allowing the detection of acute myocarditis cases. A p value < 0.05 has been considered as significant. Results: The mean ECV was significantly higher (p < 0.001) for the myocarditis group compared to the control (34.18 ± 0.43 vs. 30.04 ± 0.53%). A cut-off value of ECV = 31.60% (ROC AUC = 0.835, p < 0.001) allows to discriminate the myocarditis with a sensitivity of 80% and a specificity of 78% (positive predictive value = 92.3%, negative predictive value = 53.8% and accuracy = 79.5%). Conclusion: Myocardial ECV enabled by DECT allows to diagnose the acute myocarditis with a cut-off at 31.60% for a sensitivity of 80% and specificity of 78%.

RBRomain Bui
Romain Bui
RIRégis Iozzino
Régis Iozzino
Raphael RICHERTRaphael RICHERT
Raphael RICHERT
PRPascal Roy
Pascal Roy
LBLoïc Boussel
Loïc Boussel
Maxime DucretMaxime Ducret
Maxime Ducret
Expert determination of the third molar maturity index (I3M) constitutes one of the most common approaches for dental age estimation. This work aimed to investigate the technical feasibility of creating a decision-making tool based on I3M to support expert decision-making. Methods: The dataset consisted of 456 images from France and Uganda. Two deep learning approaches (Mask R-CNN, U-Net) were compared on mandibular radiographs, leading to a two-part instance segmentation (apical and coronal). Then, two topological data analysis approaches were compared on the inferred mask: one with a deep learning component (TDA-DL), one without (TDA). Regarding mask inference, U-Net had a better accuracy (mean intersection over union metric (mIoU)), 91.2% compared to 83.8% for Mask R-CNN. The combination of U-Net with TDA or TDA-DL to compute the I3M score revealed satisfying results in comparison with a dental forensic expert. The mean ± SD absolute error was 0.04 ± 0.03 for TDA, and 0.06 ± 0.04 for TDA-DL. The Pearson correlation coefficient of the I3M scores between the expert and a U-Net model was 0.93 when combined with TDA and 0.89 with TDA-DL. This pilot study illustrates the potential feasibility to automate an I3M solution combining a deep learning and a topological approach, with 95% accuracy in comparison with an expert.