The X-ray imaging field is currently undergoing a period of rapid technological innovation in diagnostic imaging equipment. An important recent development is the advent of new X-ray detectors, i.e., photon-counting detectors (PCD), which have been introduced in recent clinical prototype systems, called PCD computed tomography (PCD-CT) or photon-counting CT (PCCT) or spectral photon-counting CT (SPCCT) systems. PCD allows a pixel up to 200 microns pixels at iso-center, which is much smaller than that can be obtained with conventional energy integrating detectors (EID). PCDs have also a higher dose efficiency than EID mainly because of electronic noise suppression. In addition, the energy-resolving capabilities of these detectors allow generating spectral basis imaging, such as the mono-energetic images or the water/iodine material images as well as the K-edge imaging of a contrast agent based on atoms of high atomic number. In recent years, studies have therefore been conducted to determine the potential of PCD-CT as an alternative to conventional CT for chest imaging.
Aims: To evaluate spectral photon-counting CT’s (SPCCT) objective image quality characteristics in vitro, compared with standard-of-care energy-integrating-detector (EID) CT. Methods: We scanned a thorax phantom with a coronary artery module at 10 mGy on a prototype SPCCT and a clinical dual-layer EID-CT under various conditions of simulated patient size (small, medium, and large). We used filtered back-projection with a soft-tissue kernel. We assessed noise and contrast-dependent spatial resolution with noise power spectra (NPS) and target transfer functions (TTF), respectively. Detectability indices (d’) of simulated non-calcified and lipid-rich atherosclerotic plaques were computed using the non-pre-whitening with eye filter model observer. Results: SPCCT provided lower noise magnitude (9–38% lower NPS amplitude) and higher noise frequency peaks (sharper noise texture). Furthermore, SPCCT provided consistently higher spatial resolution (30–33% better TTF10). In the detectability analysis, SPCCT outperformed EID-CT in all investigated conditions, providing superior d’. SPCCT reached almost perfect detectability (AUC ≈ 95%) for simulated 0.5-mm-thick non-calcified plaques (for large-sized patients), whereas EID-CT had lower d’ (AUC ≈ 75%). For lipid-rich atherosclerotic plaques, SPCCT achieved 85% AUC vs. 77.5% with EID-CT. Conclusions: SPCCT outperformed EID-CT in detecting simulated coronary atherosclerosis and might enhance diagnostic accuracy by providing lower noise magnitude, markedly improved spatial resolution, and superior lipid core detectability.
1 March 2019 in Diagnostic and Interventional Imaging
Background: Myocardial extracellular volume (ECV) is a marker of the myocarditis inflammation burden and can be used for acute myocarditis diagnosis. Dual-energy computed tomography (DECT) enables its quantification with high concordance with cardiac magnetic resonance (CMR). Purpose: To investigate the diagnostic performance of myocardial ECV quantified on a cardiac dual-layer DECT in a population of patients with suspected myocarditis, in comparison to CMR. Methods: 78 patients were included in this retrospective monocenter study, 60 were diagnosed with acute myocarditis and 18 patients were considered as a control population, based on the 2009 Lake and Louise criteria. All subjects underwent a cardiac DECT in acute phase consisted in an arterial phase followed by a late iodine enhancement phase at 10 min after injection (1.2 mL/kg, iodinated contrast agent). ECV was calculated using the hematocrit level measured the day of DECT examinations. Non-parametric analyses have been used to test the differences between groups and the correlations between the variables. A ROC curve has been used to identify the optimal ECV cut-off discriminating value allowing the detection of acute myocarditis cases. A p value < 0.05 has been considered as significant. Results: The mean ECV was significantly higher (p < 0.001) for the myocarditis group compared to the control (34.18 ± 0.43 vs. 30.04 ± 0.53%). A cut-off value of ECV = 31.60% (ROC AUC = 0.835, p < 0.001) allows to discriminate the myocarditis with a sensitivity of 80% and a specificity of 78% (positive predictive value = 92.3%, negative predictive value = 53.8% and accuracy = 79.5%). Conclusion: Myocardial ECV enabled by DECT allows to diagnose the acute myocarditis with a cut-off at 31.60% for a sensitivity of 80% and specificity of 78%.
Expert determination of the third molar maturity index (I3M) constitutes one of the most common approaches for dental age estimation. This work aimed to investigate the technical feasibility of creating a decision-making tool based on I3M to support expert decision-making. Methods: The dataset consisted of 456 images from France and Uganda. Two deep learning approaches (Mask R-CNN, U-Net) were compared on mandibular radiographs, leading to a two-part instance segmentation (apical and coronal). Then, two topological data analysis approaches were compared on the inferred mask: one with a deep learning component (TDA-DL), one without (TDA). Regarding mask inference, U-Net had a better accuracy (mean intersection over union metric (mIoU)), 91.2% compared to 83.8% for Mask R-CNN. The combination of U-Net with TDA or TDA-DL to compute the I3M score revealed satisfying results in comparison with a dental forensic expert. The mean ± SD absolute error was 0.04 ± 0.03 for TDA, and 0.06 ± 0.04 for TDA-DL. The Pearson correlation coefficient of the I3M scores between the expert and a U-Net model was 0.93 when combined with TDA and 0.89 with TDA-DL. This pilot study illustrates the potential feasibility to automate an I3M solution combining a deep learning and a topological approach, with 95% accuracy in comparison with an expert.