Katherine Paola Escorcia Lindo

Ms. Katherine Paola Escorcia Lindo

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2022 in Biomédica
Verified
Journal Article
Open access
PDF file
LGLeidy Vanessa Hurtado Gómez
Leidy Vanessa Hurtado Gómez
DDDiana Díaz
Diana Díaz
Katherine Paola Escorcia LindoKatherine Paola Escorcia Lindo
Katherine Paola Escorcia Lindo
LFLaura Flórez
Laura Flórez
YLYesit Bello Lemus
Yesit Bello Lemus
LPLisandro Alfonso Pacheco
Lisandro Alfonso Pacheco
Introducción. Desde el primer reporte en la provincia de Wuhan (China) en el año 2019, el SARS-CoV-2 se ha diseminado por todo el mundo, provocando un enorme impacto en la salud pública. Para su diagnóstico, la Organización Mundial de la Salud ha incentivado el desarrollo de pruebas rápidas, de simple ejecución, sensibles y específicas, que complementan la RT-qPCR como prueba de referencia. La prueba RT-LAMP ha mostrado ser una excelente alternativa para la detección del SARS-CoV-2 en diferentes biofluidos.Objetivo. Validar la técnica RT-LAMP colorimétrica en muestras de hisopado nasofaríngeo previamente confirmadas por RT-qPCR, usando el protocolo Charité, Berlín, Alemania.Materiales y métodos. Un total de 153 muestras de hisopado nasofaríngeo de individuos con sospecha de COVID-19 se sometieron a RT-qPCR y RT-LAMP, usando un estuche comercial colorimétrico (NEB, Germany). La RT-LAMP se practicó con las muestras de ARN extraídas del hisopado nasofaríngeo y con muestras crudas sin previa extracción de ARN. El resultado fue evaluado por un simple cambio de color en la reacción.Resultados. La sensibilidad y especificidad de la técnica RT-LAMP para detectar el gen N del SARS-CoV-2 mediante un set de cebadores previamente reportados (set de Broughton), arrojó valores de 0,97 (0,85-1,00) y 0,81 (0,65-0,92), respectivamente, con un intervalo de confianza del 95%. Otro set de cebadores dirigidos contra otra región del mismo gen (set de Lalli) arrojó valores de sensibilidad y especificidad de 0,96 (0,78-1,00) y 0,77 (0,55-0,92), respectivamente. Sin previa extracción de ARN, se encontró que la sensibilidad fue del 0,95 (0,74-1,00) y la especificidad del 0,88 (0,64-0,99).Conclusiones. Estos resultados evidencian que la técnica RT-LAMP podría considerarse una prueba diagnóstica rápida, de fácil ejecución, libre de equipos sofisticados, sensible y específica, para el diagnóstico del SARS-CoV-2 en muestras de hisopados nasofaríngeos.

27 February 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
LGLeidy Vanessa Hurtado Gómez
Leidy Vanessa Hurtado Gómez
Katherine Paola Escorcia LindoKatherine Paola Escorcia Lindo
Katherine Paola Escorcia Lindo
JSJuan Sebastián Rosero Saucedo
Juan Sebastián Rosero Saucedo
NLNataly Solano Llanos
Nataly Solano Llanos
CSCamilo Andrés Barrios Sánchez
Camilo Andrés Barrios Sánchez
LPLisandro Alfonso Pacheco
Lisandro Alfonso Pacheco
Background: Dengue virus (DENV) infection is a significant public health concern in several tropical and subtropical regions, where early and rapid detection is crucial for effective patient management and controlling the spread of the disease. Particularly in resource-limited, rural healthcare settings where dengue is endemic, there exists a need for diagnostic methods that are both easy to perform and highly sensitive. Objective: This study focuses on the development and validation of a single-tube reverse transcription loop-mediated isothermal amplification termed TURN-RT-loop-mediated isothermal amplification (LAMP) for the detection of DENV. Methodology: The TURN-RT-LAMP assay designed in this study combines two sets of primers targeting the 5′- and 3′-UTR of DENV, with the aim to increase the sensitivity of detection. Results: Clinical validation of the TURN-RT-LAMP assay using samples collected from febrile individuals with a serological or antigenic diagnosis revealed a sensitivity of >96%. The performance of this assay was statistically compared with that of the standard diagnostic method, quantitative reverse transcription-polymerase chain reaction. Conclusions: The results support the potential of RT-LAMP as a rapid, sensitive, and specific tool for the diagnosis and surveillance of dengue, particularly suitable for field use in low-resource settings.

30 March 2023 in Biomédica
Verified
Journal Article
Open access
PDF file
CBCESAR ANTONIO BONILLA-ASALDE
CESAR ANTONIO BONILLA-ASALDE
DDDavid Alberto Díaz-Robles
David Alberto Díaz-Robles
ECEdwin César Cieza-Macedo
Edwin César Cieza-Macedo
OROriana Rivera-Lozada
Oriana Rivera-Lozada
LPLisandro Alfonso Pacheco
Lisandro Alfonso Pacheco
AHAntonio Acosta Hoyos
Antonio Acosta Hoyos

Verified
Journal Article
Open access
PDF file
roberto carlos quirozroberto carlos quiroz
roberto carlos quiroz
Katherine Paola Escorcia LindoKatherine Paola Escorcia Lindo
Katherine Paola Escorcia Lindo
APAndrea Jaruffe Pinilla
Andrea Jaruffe Pinilla
YDYirys Díaz-Olmos
Yirys Díaz-Olmos
CPCecilia Matilde Fernández Ponce
Cecilia Matilde Fernández Ponce
Elkin Navarro QuirozElkin Navarro Quiroz
Elkin Navarro Quiroz
Shannon entropy of single-cell transcript counts reflects composition and sampling. We tested whether interferon-beta (IFN-β) stimulation was associated with donor-consistent diversity changes after employing technical controls. We reanalyzed GSE96583 peripheral blood mononuclear cells from eight donors with lupus, treating donors—not the 8949 target cells obtained from them—as inferential units. Analyses included sampling without replacement at 562 unique molecular identifiers, a 750-molecule sensitivity analysis, Miller–Madow correction, IFN-gene removal, and exact compositional decomposition. Mean paired-donor raw-count plug-in entropy increased by 0.138 bits in CD14+ monocytes and 0.329 bits in FCGR3A+ monocytes and decreased by 0.080 bits in natural killer cells. Directions persisted across prespecified robustness variants. Monocyte increases accompanied higher evenness and lower transcript dominance; natural killer cells showed the opposite pattern, without consistent richness changes. Adding IFN activity to donor-, condition-, and technical-covariate-adjusted models increased R2 by at most 0.0108. Entropy contributions strongly overlapped pseudobulk expression changes. In GSE194122, the implemented binary chromatin-accessibility entropy was determined by open-peak count, precluding biological cross-modality coupling claims. These findings support a lineage-divergent association within this single lupus cohort; independent replication is required before broader biological or diagnostic interpretation.