Vasileios Kilis

Dr. Vasileios Kilis


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 August 2025 in Sustainable Energy Technologies and Assessments
Verified
Journal Article
Open access
VKVasileios Kilis
Vasileios Kilis
NPN Ploskas
N Ploskas
Giorgos PanarasGiorgos Panaras
Giorgos Panaras

20 March 2025 in Energies
Verified
Journal Article
Open access
PDF file
VKVasileios Kilis
Vasileios Kilis
GAGeorgios Anastasiadis
Georgios Anastasiadis
Nikolaos PloskasNikolaos Ploskas
Nikolaos Ploskas
Giorgos PanarasGiorgos Panaras
Giorgos Panaras
Electrification is a key priority of the European Union, focusing on saving energy resources and mitigating carbon emissions through enhancing restrictions on relative policies and initiatives. For such goals to be achieved, investing in renewable energy technologies on large- and small-scale projects is promoted. These efforts were implemented in the building sector too, highlighting the importance of optimal decisions in improving the energy performance of buildings, from an economic, energy and environmental perspective. In this context, this paper aims to elaborate a decision-making methodology for building thermal design, considering the optimal selection and operation of multi-energy systems focused on renewable technologies. Solar thermal collectors, photovoltaic systems and heat pumps were included in an Energy Hub for meeting the heating, cooling and domestic hot water energy demand. Optimal decisions were achieved by formulating Mathematical Programming models in GAMS, for minimizing economic, energy and environmental parameters of the systems under a life cycle perspective. The proposed methodology was implemented in a residential building case study. Results show that combining heat pumps with photovoltaics is preferable for all of the examined criteria, while a sensitivity analysis of the economic, energy and environmental parameters, influencing the energy mixture, leads to optimal solutions with the participation of different energy systems.

6 June 2026 in Energies
Verified
Journal Article
Open access
PDF file
MSMichail Sourgoutsidis
Michail Sourgoutsidis
Leonidas ZouloumisLeonidas Zouloumis
Leonidas Zouloumis
VKVasileios Kilis
Vasileios Kilis
EGEffrosyni Giama
Effrosyni Giama
AVAndreas P. Vouros
Andreas P. Vouros
Giorgos PanarasGiorgos Panaras
Giorgos Panaras
Accurate design and performance assessment of solar thermal domestic hot water systems coupled with a heat pump auxiliary typically requires transient simulation, as the system’s behavior depends on multiple interactions among collector characteristics, storage stratification, control logic, weather, and draw-off timing. Monthly methods such as the f-chart are useful for first-pass estimates, but they do not resolve stratification, thermostat operation, or demand timing, and they may become inaccurate for stratified thermostat-controlled systems. Direct comparisons of locally inspectable symbolic and black-box surrogate families for this system class remain limited. A 10,982-case development dataset was generated from minute-resolved annual MATLAB simulations, parameterized by collector area, optical efficiency, and first- and second-order loss coefficients. Three surrogate families were benchmarked under a unified protocol, random forest-assisted shape-constrained symbolic regression (SR), feed-forward artificial neural network (ANN) models, and Automatic Learning of Algebraic Models for Optimization (ALAMO), with the f-chart used as a monthly reference method. The targets were the 12 monthly solar fractions under the direct solar heat definition and the corresponding annual mean solar fraction, evaluated on the same independent 991-case test set. SR achieved the lowest average error (mean absolute percentage error, MAPE = 0.82%; root mean square error, RMSE = 0.006), followed by the ANN (MAPE = 2.07%, RMSE = 0.028) and ALAMO (MAPE = 3.67%, RMSE = 0.060), with Nash–Sutcliffe efficiency (NSE) values above 0.98 for all models. Evaluation times were 0.0026–0.124 s per target, compared with about 1000 s for one full-year simulation. These results define the study as a common protocol benchmark within the studied simulator-defined envelope. SR gives the strongest accuracy with local symbolic inspectability, the ANN remains the flexible retrainable option, and ALAMO provides compact algebraic evaluation with the shortest learned model runtime.