This report provides the mathematical commissioning instructions for the evaluation of beam matching between two different linear accelerators. Test packages were first obtained including an open beam profile, a wedge beam profile and a depth–dose curve, each from a 10×10 cm2 beam. From these plots, a spatial error (SE) and a percentage dose error were introduced to form new plots. These three test package curves and the associated error curves were then differentiated in space with respect to dose for a first and second derivative to determine the slope and curvature of each data set. The derivatives, also known as bandwidths, were analysed to determine the level of acceptability for the beam matching test described in this study. The open and wedged beam profiles and depth–dose curve in the build-up region were determined to match within 1% dose error and 1-mm SE at 71.4% and 70.8% for of all points, respectively. For the depth–dose analysis specifically, beam matching was achieved for 96.8% of all points at 1%/1 mm beyond the depth of maximum dose. To quantify the beam matching procedure in any clinic, the user needs to merely generate test packages from their reference linear accelerator. It then follows that if the bandwidths are smooth and continuous across the profile and depth, there is greater likelihood of beam matching. Differentiated spatial and percentage variation analysis is appropriate, ideal and accurate for this commissioning process. We report a mathematically rigorous formulation for the qualitative evaluation of beam matching between linear accelerators.
Water is treated as radiological equivalent to human tissue. While this seems justified, there is neither mathematical proof nor sufficient experimental evidence that a water phantom can be treated as equivalent to human tissue. The aim of this work is to simulate and validate a water phantom that is tissue equivalent in terms of the dosimetric characteristics of both water and human tissue Dynamic, intensity-modulated radiotherapy plans for two head and neck, one brain, one pelvis, and three lung/mediastinum cases were chosen for this study. Using a treatment planning system (TPS) (Eclipse, Varian Medical System, Polo Alto, CA, USA) and Anisotropic Analytic Algorithm in a grid resolution of 5 mm × 5 mm, a patient-equivalent water phantom was calculated from all rays in the isocentric plane as an array of water equivalent depths (dWE). These rays were plotted versus isocentric separation and ray-tracing direction. Planar doses were compared between the isocentric plane in the patient computed tomography and the water equivalent phantom using gamma criteria of 2%–2 mm and 3%–3 mm. Except in one lung case, >95% gamma agreement was seen when using 3%–3 mm and >90% pass rate was seen when using 2%–2 mm. For head and neck cases, gamma-fail was restricted to the periphery. For mediastinum cases, gamma-fail was restricted to the lungs. This study demonstrates that a heterogeneous patient can be converted to a water phantom with comparable dosimetric characteristics and disagreements restricted to the lung area for both modulated and open beams. Potential sources of error include the dWE calculation and TPS dose computation.
Monte Carlo (MC) simulations are often used in calculations of radiation transport to enable accurate prediction of radiation-dose, even though the computation is relatively time-consuming. In a typical MC simulation, significant computation time is allocated to following non-important events. To address this issue, variance reduction techniques (VRTs) have been suggested for reducing the statistical variance for the same computation time. Among the available MC simulation codes, electron gamma shower (National Research Council of Canada) (EGSnrc) is a general-purpose coupled electron-photon transport code that also features an even-handed, rich set of VRTs. The most well-known VRTs are the photon splitting, Russian roulette (RR), and photon cross-section enhancement (XCSE) techniques. The objective of this work was to determine the optimal combination of VRTs that increases the simulation speed and the efficiency of simulation, without compromising its accuracy. Selection of VRTs was performed using EGSnrc MC User codes, such as cavity and egs_chamber, for simulating various ion chamber geometries using 6 MV photon beams and 1.25 MeV60Co photon beams. The results show that the combination of XCSE and RR yields the highest efficiency for ion-chamber dose calculations inside a 30 cm × 30 cm × 30 cm water phantom. Hence, properly selecting a different VRT without altering the underlying physics increases the efficiency of MC simulations for ion-chamber dose calculation.
8 May 2014 in Journal of Applied Clinical Medical Physics
The aim of this study was to assess the performance of a gantry‐mounted detector system and a couch set detector system using a systematic multileaf collimator positional error manually introduced for volumetric‐modulated arc therapy. Four head and neck and esophagus VMAT plans were evaluated by measurement using an electronic portal imaging device and an ion chamber array. Each plan was copied and duplicated with a 1 mm systematic MLC positional error in the left leaf bank. Direct comparison of measurements for plans with and without the error permitted observational characteristics for quality assurance performance between detectors. A total of 48 different plans were evaluated for this testing. The mean percentage planar dose differences required to satisfy a 95% match between plans with and without the MLCPE were 5.2% ± 0.5% for the chamber array with gantry motion, 8.12% ± 1.04% for the chamber array with a static gantry at 0°, and 10.9% ± 1.4% for the EPID with gantry motion. It was observed that the EPID was less accurate due to overresponse of the MLCPE in the left leaf bank. The EPID always images bank‐A on the ipsilateral side of the detector, whereas for a chamber array or for a patient, that bank changes as it crosses the ‐90° or +90° position. A couch set detector system can reproduce the TPS calculated values most consistently. We recommend it as the most reliable patient specific QA system for MLC position error testing. This research is highlighted by the finding of up to 12.7% dose variation for H/N and esophagus cases for VMAT delivery, where the mere source of error was the stated clinically acceptability of 1 mm MLC position deviation of TG‐142.PACS numbers: 87.56.‐v, 87.55.‐x, 07.57.KP, 29.40.‐n, 85.25.Pb