Representative Publications

View All Publications
1 July 2012 in British Journal of Radiology
Verified
Journal Article
Closed access
AMA Manikandan
A Manikandan
Biplab SarkarBiplab Sarkar
Biplab Sarkar
RHR Holla
R Holla
TVT R Vivek
T R Vivek
NSN Sujatha
N Sujatha
Objectives: The purpose of this study was to demonstrate quality assurance checks for accuracy of gantry speed and position, dose rate and multileaf collimator (MLC) speed and position for a volumetric modulated arc treatment (VMAT) modality (Synergy® S; Elekta, Stockholm, Sweden), and to check that all the necessary variables and parameters were synchronous. Methods: Three tests (for gantry position–dose delivery synchronisation, gantry speed–dose delivery synchronisation and MLC leaf speed and positions) were performed. Results: The average error in gantry position was 0.5° and the average difference was 3 MU for a linear and a parabolic relationship between gantry position and delivered dose. In the third part of this test (sawtooth variation), the maximum difference was 9.3 MU, with a gantry position difference of 1.2°. In the sweeping field method test, a linear relationship was observed between recorded doses and distance from the central axis, as expected. In the open field method, errors were encountered at the beginning and at the end of the delivery arc, termed the “beginning” and “end” errors. For MLC position verification, the maximum error was −2.46 mm and the mean error was 0.0153 ±0.4668 mm, and 3.4% of leaves analysed showed errors of >±1 mm. Conclusion: This experiment demonstrates that the variables and parameters of the Synergy® S are synchronous and that the system is suitable for delivering VMAT using a dynamic MLC.

1 February 2018 in Cancer/Radiothérapie
Verified
Journal Article
Closed access
Biplab SarkarBiplab Sarkar
Biplab Sarkar
AMA. Munshi
A. Munshi
AMA. Manikandan
A. Manikandan
SRS. Roy
S. Roy
TGT. Ganesh
T. Ganesh
APA. Pradhan
A. Pradhan

18 May 2017 in Australasian Physics & Engineering Sciences in Medicine
Verified
Journal Article
Closed access
PDF file
AMAnusheel Munshi
Anusheel Munshi
Biplab SarkarBiplab Sarkar
Biplab Sarkar
SASatheeshkumar Anbazhagan
Satheeshkumar Anbazhagan
UGUpendra K. Giri
Upendra K. Giri
HKHarpreet Kaur
Harpreet Kaur
BMBidhu Kalyan Mohanti
Bidhu Kalyan Mohanti

22 March 2018 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
Biplab SarkarBiplab Sarkar
Biplab Sarkar
JRJyotirmoy Ray
Jyotirmoy Ray
TGTharmarnadar Ganesh
Tharmarnadar Ganesh
AMArjunan Manikandan
Arjunan Manikandan
AMAnusheel Munshi
Anusheel Munshi
BMBidhu Kalyan Mohanti
Bidhu Kalyan Mohanti
The aim of this article is to derive and verify a mathematical formulation for the reduction of the six-dimensional (6D) positional inaccuracies of patients (lateral, longitudinal, vertical, pitch, roll and yaw) to three-dimensional (3D) linear shifts. The formulation was mathematically and experimentally tested and verified for 169 stereotactic radiotherapy patients. The mathematical verification involves the comparison of any (one) of the calculated rotational coordinates with the corresponding value from the 6D shifts obtained by cone beam computed tomography (CBCT). The experimental verification involves three sets of measurements using an ArcCHECK phantom, when (i) the phantom was not moved (neutral position: 0MES), (ii) the position of the phantom shifted by 6D shifts obtained from CBCT (6DMES) from neutral position and (iii) the phantom shifted from its neutral position by 3D shifts reduced from 6D shifts (3DMES). Dose volume histogram and statistical comparisons were made between 〈 T P S C A L - 0 M E S 〉 and 〈 3 D M E S - 6 D M E S 〉 . The mathematical verification was performed by a comparison of the calculated and measured yaw ( γ °) rotation values, which gave a straight line, Y = 1 X with a goodness of fit as R 2 = 0.9982. The verification, based on measurements, gave a planning target volume receiving 100% of the dose (V100%) as 99.1 ± 1.9%, 96.3 ± 1.8%, 74.3 ± 1.9% and 72.6 ± 2.8% for the calculated treatment planning system values TPSCAL, 0MES, 3DMES and 6DMES, respectively. The statistical significance ( p -values: paired sample t -test) of V100% were found to be 0.03 for the paired sample 〈 3 D M E S - 6 D M E S 〉 and 0.01 for 〈 0 M E S - T P S C A L 〉 . In this paper, a mathematical method to reduce 6D shifts to 3D shifts is presented. The mathematical method is verified by using well-matched values between the measured and calculated γ °. Measurements done on the ArcCHECK phantom also proved that the proposed methodology is correct. The post-correction of the table position condition introduces a minimal spatial dose delivery error in the frameless stereotactic system, using a 6D motion enabled robotic couch. This formulation enables the reduction of 6D positional inaccuracies to 3D linear shifts, and hence allows the treatment of patients with frameless stereotactic radiosurgery by using only a 3D linear motion enabled couch.

1 January 2011 in Journal of Medical Physics
Verified
Journal Article
Open access
PDF file
AMA Manikandan
A Manikandan
Biplab SarkarBiplab Sarkar
Biplab Sarkar
DPDavidA Perianayagam
DavidA Perianayagam
RHR Holla
R Holla
TVTr Vivek
Tr Vivek
NSN Sujatha
N Sujatha
For high dose rate (HDR) brachytherapy, independent treatment verification is needed to ensure that the treatment is performed as per prescription. This study demonstrates dosimetric quality assurance of the HDR brachytherapy using a commercially available two-dimensional ion chamber array called IMatriXX, which has a detector separation of 0.7619 cm. The reference isodose length, step size, and source dwell positional accuracy were verified. A total of 24 dwell positions, which were verified for positional accuracy gave a total error (systematic and random) of −0.45 mm, with a standard deviation of 1.01 mm and maximum error of 1.8 mm. Using a step size of 5 mm, reference isodose length (the length of 100% isodose line) was verified for single and multiple catheters of same and different source loadings. An error ≤1 mm was measured in 57% of tests analyzed. Step size verification for 2, 3, 4, and 5 cm was performed and 70% of the step size errors were below 1 mm, with maximum of 1.2 mm. The step size ≤1 cm could not be verified by the IMatriXX as it could not resolve the peaks in dose profile.

1 November 2013 in British Journal of Radiology
Verified
Journal Article
Closed access
Biplab SarkarBiplab Sarkar
Biplab Sarkar
AMA Manikandan
A Manikandan
MNM Nandy
M Nandy
MGM S Gossman
M S Gossman
SCSureka CS
Sureka CS
NSN Sujatha
N Sujatha
This report provides the mathematical commissioning instructions for the evaluation of beam matching between two different linear accelerators. Test packages were first obtained including an open beam profile, a wedge beam profile and a depth–dose curve, each from a 10×10 cm2 beam. From these plots, a spatial error (SE) and a percentage dose error were introduced to form new plots. These three test package curves and the associated error curves were then differentiated in space with respect to dose for a first and second derivative to determine the slope and curvature of each data set. The derivatives, also known as bandwidths, were analysed to determine the level of acceptability for the beam matching test described in this study. The open and wedged beam profiles and depth–dose curve in the build-up region were determined to match within 1% dose error and 1-mm SE at 71.4% and 70.8% for of all points, respectively. For the depth–dose analysis specifically, beam matching was achieved for 96.8% of all points at 1%/1 mm beyond the depth of maximum dose. To quantify the beam matching procedure in any clinic, the user needs to merely generate test packages from their reference linear accelerator. It then follows that if the bandwidths are smooth and continuous across the profile and depth, there is greater likelihood of beam matching. Differentiated spatial and percentage variation analysis is appropriate, ideal and accurate for this commissioning process. We report a mathematically rigorous formulation for the qualitative evaluation of beam matching between linear accelerators.