Juan Carlos Vielma Quintero

Mr. Juan Carlos Vielma Quintero

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2022 in Buildings
Verified
Journal Article
Open access
PDF file
Maria Cristina PorcuMaria Cristina Porcu
Maria Cristina Porcu
Juan Vielma-PerezJuan Vielma-Perez
Juan Vielma-Perez
GPGavino Pais
Gavino Pais
DBDiego Andrés Osorio Bravo
Diego Andrés Osorio Bravo
JQJuan Carlos Vielma Quintero
Juan Carlos Vielma Quintero
Due to their excellent seismic behavior, shear wall-type concrete buildings are very popular in earthquake-prone countries like Chile. According to current seismic regulations, the performance of such structures can be indifferently assessed through linear or non-linear methods of analysis. Although all the code-compliant approaches supposedly lead to a safe design, linear approaches may be in fact less precise for catching the actual seismic performance of ductile and dissipative structures, which can even result in unconservative design where comparatively stiff buildings like reinforced-concrete shear-wall (RC-SW) buildings are concerned. By referring to a mid-rise multistory RC-SW building built in Chile and designed according to the current seismic Chilean code, the paper investigates the effectiveness of the linear dynamic analyses to predict the seismic performance of such kind of structures. The findings show that the code-compliant linear approaches (Modal Response Spectrum Analysis and Linear Time-History Analysis) may significantly underestimate the displacement demand in RC-SW buildings. This is highlighted by the comparison with the results obtained from the Non-Linear Time-History Analysis, which is expected to give more realistic results. A set of ten spectrum-consistent Chilean earthquakes was considered to carry out the time-history analyses while a distributed-plasticity fiber-based approach was adopted to model the non-linear behavior of the considered building. The paper highlights how the risk of an unsafe design may become higher when reference is made to the Chilean code, the latter considering only the Modal Response Spectrum Analysis (MRSA) without even providing corrective factors to estimate the inelastic displacement demand. The paper checks the effectiveness of some amplifying factors taken from the literature with reference to the case-study shear-wall building, concluding that they are not effective enough. The paper also warns against the danger of local soft-story collapse mechanisms, which are typical of reinforced concrete frames but may also affect RC-SW buildings when weaker structural parts made by column-like walls are present at the ground floor.

9 June 2023 in Buildings
Verified
Journal Article
Open access
PDF file
JQJuan Carlos Vielma Quintero
Juan Carlos Vielma Quintero
JCJorge Carvallo
Jorge Carvallo
Juan Vielma-PerezJuan Vielma-Perez
Juan Vielma-Perez
Performance-based design has been increasingly used in practice due to computational improvements, the sophistication and dissemination of nonlinear analysis methods, and the development of commercial programs that facilitate its use. We can evaluate the nonlinear effects of seismic events of great magnitude on the structural behavior of a building, verify preliminary designs based on force-based methods, validate standard design regulations, determine deformations, and calculate accelerations that can be translated into parameters of structural damage and economic losses, among other functions. Guiding documents have presented methodologies to establish requirements, evaluation criteria, analysis methods, etc., each with different objectives, revealing the lack of a consensus method. In this paper, the state of the art of performance-based design is studied, and some of the most relevant methods, such as ASCE 41-17, ASCE 7-16, and the alternative procedure of ACHISINA, are applied to a structure with shear walls designed according to current Chilean regulations. Additionally, modal-response spectrum analysis is used. The modeling of the earthquake-resistant structure of the building, the preparation of seismic records, and the consideration of aspects that limit the rigorous application of the method are addressed in a nonelastic analysis framework. Results obtained in the respective analyses that are used to evaluate the structural performance are compared with the corresponding performance criteria for each standard, considering the characteristics of each methodology. Moreover, the main complications that can occur during the application of the methods are discussed.

19 March 2024 in Symmetry
Verified
Journal Article
Open access
PDF file
JQJuan Carlos Vielma Quintero
Juan Carlos Vielma Quintero
EDEdgar Giovanny Diaz-Segura
Edgar Giovanny Diaz-Segura
Juan Vielma-PerezJuan Vielma-Perez
Juan Vielma-Perez
Seismic-resistant design incorporates measures to ensure that structures perform adequately under specific limit states, focusing on seismic forces derived from both the equivalent static and spectral modal methods. This study examined buildings on slopes in densely built urban areas, a common scenario in Latin American cities with high seismic risks. The adjustment of high-rise buildings to sloping terrains induces structural asymmetry, leading to plan and elevation irregularities that significantly impact their seismic response. This paper explores the asymmetry in medium-height reinforced concrete frame buildings on variable inclines (0°, 15°, 30°, and 45°) and its effect on their nonlinear response, assessed via displacements, rotations, and damage. Synthetic accelerograms matched with Chile’s high seismic hazard design spectrum, scaled for different performance states and seismic records from the Chilean subduction zone, were applied. The findings highlight structural asymmetry’s role in influencing nonlinear response parameters such as ductility, transient interstory drifts, and roof rotations, and uncover element demand distributions surpassing conventional analysis and in earthquake-resistant design expectations.

31 May 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Juan Vielma-PerezJuan Vielma-Perez
Juan Vielma-Perez
JQJuan Carlos Vielma Quintero
Juan Carlos Vielma Quintero
EDEdgar Giovanny Diaz-Segura
Edgar Giovanny Diaz-Segura
Currently, seismic-resistant design is carried out by applying codes that are periodically updated based on research findings and lessons learned from major seismic events. In the case of buildings located on sloping terrains and those composed of reinforced concrete shear walls, there is a notable lack of specific design provisions in existing standards. For this reason, the methodology outlined in FEMA P695 was applied in the present study, with the aim of validating the response reduction factor used for designing this type of structure in Chile. Additionally, other parameters that allow for the evaluation of design performance or serve as complementary indicators—such as ductility, the overstrength factor, and the displacement amplification factor—were determined. To conduct this study, a series of archetype buildings were designed, varying the slope inclination from 0° to 45°. The results show that, although the current design approach ensures safety, it is necessary to specify different design parameters for the directions parallel and orthogonal to the slope in order to optimize the seismic performance of the buildings.

5 April 2025 in Buildings
Verified
Journal Article
Open access
PDF file
MMMario Alejandro Gutiérrez Morales
Mario Alejandro Gutiérrez Morales
JQJuan Carlos Vielma Quintero
Juan Carlos Vielma Quintero
JCJorge Carvallo
Jorge Carvallo
Juan Vielma-PerezJuan Vielma-Perez
Juan Vielma-Perez
Performance-based seismic design (PBD) has emerged as a key approach for rationalizing prescriptive code provisions and improving the explicit assessment of structural performance. In Chile, where reinforced concrete shear wall buildings are the predominant structural typology, evaluating their seismic response beyond traditional linear methodologies is crucial. This study assesses the seismic performance of a representative Chilean shear wall residential building using the ACHISINA manual’s performance-based seismic design framework. A nonlinear static (pushover) analysis is performed to verify compliance with prescribed design criteria, incorporating capacity design principles and a moment envelope approach to prevent premature yielding in upper stories. The results confirm that the building meets the performance objectives for both Immediate Occupancy and Additional Deformation Capacity limit states. The application of capacity design effectively controls shear demand, preventing brittle failure, while the flexural design ensures the formation of the yielding mechanism (plastic hinge) at the intended critical section. Additionally, the study highlights the limitations of pushover analysis in capturing higher-mode effects and recommends complementary nonlinear time-history analysis (NLTHA) for a more comprehensive assessment. The computed response reduction factors exceed those used in the prescriptive design, suggesting a conservatively safe approach in current Chilean practice. This research reinforces the need to integrate performance-based methodologies into Chilean seismic design regulations, particularly for shear wall structures. It provides valuable insights into the advantages and limitations of current design practices and proposes improvements for future applications.

28 November 2025 in Buildings
Verified
Journal Article
Open access
PDF file
DQDaniel Quezada-Cofré
Daniel Quezada-Cofré
JQJuan Carlos Vielma Quintero
Juan Carlos Vielma Quintero
Alvaro LopezAlvaro Lopez
Alvaro Lopez
Juan Vielma-PerezJuan Vielma-Perez
Juan Vielma-Perez
As a result of recent seismic events, it has been observed that earthquake-resistant design worldwide has evolved to the point where structures are generally able to respond adequately to such natural demands. Nevertheless, it has also become evident that nonstructural components and contents anchored to structures have not exhibited equally satisfactory performance. To study the effects of earthquakes on these elements and compare the results with current Chilean code provisions, the present study focuses on determining the maximum absolute floor accelerations in a shear wall building, the most common structural typology in Chilean residential construction. The structure was subjected to destructive seismic excitations representative of the earthquakes that struck Chile in 2010, 2015, and 2017. Based on the obtained accelerations, the demands on nonstructural elements were critically assessed using the current Chilean seismic design code. In this context, the nonlinear behavior of the supporting structure was considered with a damping ratio of 5%. Through time history simulations, floor acceleration records were generated, from which pseudo-accelerations were calculated. Finally, by applying an innovative procedure developed in this study, floor acceleration amplification factors were determined, as well as acceleration spectra intended to guide a more adequate design of nonstructural components.