Emma Alexander

Dr. Emma Alexander

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 May 2020 in Methods and Applications in Fluorescence
Verified
Journal Article
Closed access
PDF file
JKJoseph Kimball
Joseph Kimball
JCJose Luis Chavez
Jose Luis Chavez
LUCA CERESALUCA CERESA
LUCA CERESA
EAEmma Alexander
Emma Alexander
ZNZhangatay Nurekeyev
Zhangatay Nurekeyev
ZGZygmunt Gryczynski
Zygmunt Gryczynski
Fluorescence technologies have been the preferred method for detection, analytical sensing, medical diagnostics, biotechnology, imaging, and gene expression for many years. Fluorescence becomes essential for studying molecular processes with high specificity and sensitivity through a variety of biological processes. A significant problem for practical fluorescence applications is the apparent non-linearity of the fluorescence intensity resulting from inner-filter effects, sample scattering, and absorption of intrinsic components of biological samples. Sample absorption can lead to the primary inner filter effect (Type I inner filter effect) and is the first factor that should be considered. This is a relatively simple factor to be controlled in any fluorescence experiment. However, many previous approaches have given only approximate experimental methods for correcting the deviation from expected results. In this part we are discussing the origin of the primary inner filter effect and presenting a universal approach for correcting the fluorescence intensity signal in the full absorption range. Importantly, we present direct experimental results of how the correction works. One considers problems emerging from varying absorption across its absorption spectrum for all fluorophores. We use Rhodamine 800 and demonstrate how to properly correct the excitation spectra in a broad wavelength range. Second is the effect of an inert absorber that attenuates the intensity of the excitation beam as it travels through the cuvette, which leads to a significant deviation of observed results. As an example, we are presenting fluorescence quenching of a tryptophan analog, NATA, by acrylamide and we show how properly corrected results compare to the initial erroneous results. The procedure is generic and applies to many other applications like quantum yield determination, tissue/blood absorption, or acceptor absorption in FRET experiments.

24 May 2021 in Methods and Applications in Fluorescence
Verified
Journal Article
Closed access
PDF file
LUCA CERESALUCA CERESA
LUCA CERESA
JKJoseph Kimball
Joseph Kimball
JCJose Luis Chavez
Jose Luis Chavez
EAEmma Alexander
Emma Alexander
ZNZhangatay Nurekeyev
Zhangatay Nurekeyev
ZGZygmunt Gryczynski
Zygmunt Gryczynski
Fluorescence is an established technology for studying molecular processes and molecular interactions. More recently fluorescence became a leading method for detection, sensing, medical diagnostics, biotechnology, imaging, DNA analysis, and gene expression. Consequently, precise and accurate measurements in various conditions have become more critical for proper result interpretations. Previously, in Part 1, we discussed inner filter effect type I, which is a consequence of the instrumental geometrical sensitivity factor and absorption of the excitation. In this part, we analyze inner filter effect type II and discuss the practical consequences for fluorescence measurements in samples of high optical density (absorbance/scattering). We consider both the standard square and front-face experimental configurations, discuss experimental approaches to limit/mitigate the effect and discuss methods for correcting and interpreting experimental results.

1 July 2020 in Journal of Photochemistry and Photobiology B: Biology
Verified
Journal Article
Closed access
JCJose Chavez
Jose Chavez
LCLuca Ceresa
Luca Ceresa
EAEmma Alexander
Emma Alexander
JKJoseph Kimball
Joseph Kimball
TSTanya Shtoyko
Tanya Shtoyko
IGIgnacy Gryczynski
Ignacy Gryczynski

2 February 2022 in Methods and Applications in Fluorescence
Verified
Journal Article
Closed access
JCJose Chavez
Jose Chavez
LUCA CERESALUCA CERESA
LUCA CERESA
JRJohn M Reeks
John M Reeks
YSYuri M Strzhemechny
Yuri M Strzhemechny
JKJoseph Kimball
Joseph Kimball
IGIgnacy Gryczynski
Ignacy Gryczynski
We studied room temperature phosphorescence of tryptophan (TRP) embedded in poly (vinyl alcohol) films. With UV (285 nm) excitation, the phosphorescence spectrum of tryptophan appears at about 460 nm. We also observed the TRP phosphorescence with blue light excitation at 410 nm, well outside of the S 0 →S 1 absorption. This excitation reaches the triplet state of tryptophan directly without the involvement of the singlet excited state. The phosphorescence lifetime of tryptophan is in the sub-millisecond range. The long-wavelength direct excitation to the triplet state results in high phosphorescence anisotropy which can be useful in macromolecule dynamics study via time-resolved phosphorescence.

26 September 2022 in Methods and Applications in Fluorescence
Verified
Journal Article
Closed access
EAEmma Alexander
Emma Alexander
MSMichael Seung
Michael Seung
JCJose Chavez
Jose Chavez
LUCA CERESALUCA CERESA
LUCA CERESA
JKJoseph Kimball
Joseph Kimball
ZGZygmunt Gryczynski
Zygmunt Gryczynski
Excitation and emission (observation) conditions heavily impact fluorescence measurements. Both observed spectra and intensity decays (fluorescence lifetimes), when incorrectly measured, may lead to incorrect data interpretations. In this report, we discuss the role of observation conditions in steady-state and time-resolved (lifetime) fluorescence measurements. We demonstrate the importance of the correction for uneven transmissions of vertical and horizontal polarizations of emission light through the detection system. The necessity of using so-called total fluorescence intensity or intensity measured under magic angle (MA) conditions has been demonstrated for both steady-state and time-resolved fluorescence measurements. The dependence of lifetime measurements on observation (emission) wavelengths is also discussed. Two fluorophores, rhodamine 6G (R6G) and 4,4 Dimethylamino-cyano stilbene (DCS) in two solvents - ethanol and glycerol have been used in order to cover a broad range of dye polarities and solvent viscosities.

2 November 2023 in Methods and Applications in Fluorescence
Verified
Journal Article
Open access
PDF file
EAEmma Alexander
Emma Alexander
LUCA CERESALUCA CERESA
LUCA CERESA
DPDanh Pham
Danh Pham
ZGZygmunt Gryczynski
Zygmunt Gryczynski
IGIgnacy Gryczynski
Ignacy Gryczynski
We studied the effect of annealing on the luminescence of Coumarin 106 (C106) in poly (vinyl alcohol) films (PVA films). The samples and reference polymer films were treated at temperatures between 100 °C and 150 °C (212 F and 302 F) for various times. After cooling and smoothing, the samples and references were measured at room temperature. We observed that the PVA polymer (reference films) changes its optical properties with annealing at higher temperatures, affecting the baselines in absorption and the backgrounds in emission measurements. This requires precise background subtractions and control of the signal-to-noise ratio. Whereas the fluorescence intensity of C106 in PVA films modestly decreases with annealing, the phosphorescence depends dramatically and progressively increases by many folds. The fluorescence quantum yields and lifetimes decrease with the annealing, which suggests an increase in the non-radiative processes in the singlet excited state S1. The increase in the phosphorescence intensities results from increased intersystem crossing (ISC), which also decreases fluorescence. We also studied the effect of annealing on phosphorescence with the directly excited triplet state of C106. In this case, two processes are affected by annealing, S0→T1 absorption and T1→S0 phosphorescence. The long-wavelength excitation (475 nm) avoids PVA polymer excitation. The phosphorescence lifetime decreases with annealing while the phosphorescence intensity increases. These changes suggest that the radiative rate of T1 → S0 increases with annealing.