Information technology (IT) security has become a major concern due to the growing demand for information and massive development of client/server applications for various types of applications running on modern IT infrastructure. How has security been taken into account and which paradigms are necessary to minimize security issues while increasing efficiency, reducing the influence on transmissions, ensuring protocol independency and achieving substantial performance? We have found cryptography to be an absolute security mechanism for client/server architectures, and in this study, a new security design was developed with the MODBUS protocol, which is considered to offer phenomenal performance for future development and enhancement of real IT infrastructure. This study is also considered to be a complete development because security is tested in almost all ways of MODBUS communication. The computed measurements are evaluated to validate the overall development, and the results indicate a substantial improvement in security that is differentiated from conventional methods.
We developed a design of Intelligent Healthcare Data Management System using nanosensors (IHDMS) and composed an application for mobile device. The proposed IHDMS will coordinate the healthcare data of the patients from nanosensors and transforms it into a worldwide consumed standard HL7 (Health Level Seven) for conversion of healthcare data. This converted data dispatches to a server of its system. The battery lifetime of the facility is feasible to increase, the memory usage is less than 100 KB, and it operates all data by employing few and far between resources. Moreover, the proposed system decreases the waiting time in the transposing data, and secured channel was used for the server of the healthcare center in the running HL7 format data.
20 November 2015 in Multimedia Tools and Applications
Secondary trigger finger caused by trauma to the hand, especially associated with partial flexor tendon rupture, is not a common condition. Thus, the clinical manifestations of these patients are not well-known. The aim of this study is to present secondary trigger finger caused by a neglected partial flexor tendon rupture including discussion of the mechanism and treatment. We retrospectively reviewed the records of 6 patients with trigger finger caused by a neglected partial flexor tendon rupture who had been treated with exploration, debridement, and repairing of the ruptured tendon from August 2010 to May 2015. The average patient age was 41 years (range, 23–59). The time from injury to treatment averaged 4.7 months. The average follow-up period was 9 months (range, 4–18). Functional outcome was evaluated from a comparison between the Quick-disabilities of the arm, shoulder, and hand (DASH) score and the visual analogue scale (VAS) for pain, which were measured at the time of preoperation and final follow up. Four patients showed partial rupture of the flexor digitorum profundus (FDP) tendon and 3 showed partial rupture of the flexor digitorun superficialis (FDS) tendon. Both the FDP and FDS tendons were partially ruptured in 2 patients, and the remaining patient had a partial rupture of the flexor pollicis longus tendon. All patients regained full range of motion, and there has been no recurrence of triggering. The average VAS score decreased from 3.6 (range, 3–5) preoperatively to 0.3 (range, 0–1) at the final follow up. The average Quick-DASH score decreased from 33.6 preoperatively to 5.3 at the final follow up. When we encounter patients with puncture or laceration wounds in flexor zone 2, even when the injury appears to be simple, partial flexor tendon laceration must be taken into consideration and early exploration is recommended.
In Industrial systems, Supervisory control and data acquisition (SCADA) system, the pseudo-transport layer of the distributed network protocol (DNP3) performs the functions of the transport layer and network layer of the open systems interconnection (OSI) model. This study used a simulation design of water pumping system, in-which the network nodes are directly and wirelessly connected with sensors, and are monitored by the main controller, as part of the wireless SCADA system. This study also intends to focus on the security issues inherent in the pseudo-transport layer of the DNP3 protocol. During disassembly and reassembling processes, the pseudo-transport layer keeps track of the bytes sequence. However, no mechanism is available that can verify the message or maintain the integrity of the bytes in the bytes received/transmitted from/to the data link layer or in the send/respond from the main controller/sensors. To properly and sequentially keep track of the bytes, a mechanism is required that can perform verification while bytes are received/transmitted from/to the lower layer of the DNP3 protocol or the send/respond to/from field sensors. For security and byte verification purposes, a mechanism needs to be proposed for the pseudo-transport layer, by employing cryptography algorithm. A dynamic choice security buffer (SB) is designed and employed during the security development. To achieve the desired goals of the proposed study, a pseudo-transport layer stack model is designed using the DNP3 protocol open library and the security is deployed and tested, without changing the original design.