Michael (Misha) Chertkov

Prof. Dr. Michael (Misha) Chertkov

orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 January 2013 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
FDFlorian Dörfler
Florian Dörfler
MCMichael (Misha) Chertkov
Michael (Misha) Chertkov
FBFrancesco Bullo
Francesco Bullo
The emergence of synchronization in a network of coupled oscillators is a fascinating topic in various scientific disciplines. A widely adopted model of a coupled oscillator network is characterized by a population of heterogeneous phase oscillators, a graph describing the interaction among them, and diffusive and sinusoidal coupling. It is known that a strongly coupled and sufficiently homogeneous network synchronizes, but the exact threshold from incoherence to synchrony is unknown. Here, we present a unique, concise, and closed-form condition for synchronization of the fully nonlinear, nonequilibrium, and dynamic network. Our synchronization condition can be stated elegantly in terms of the network topology and parameters or equivalently in terms of an intuitive, linear, and static auxiliary system. Our results significantly improve upon the existing conditions advocated thus far, they are provably exact for various interesting network topologies and parameters; they are statistically correct for almost all networks; and they can be applied equally to synchronization phenomena arising in physics and biology as well as in engineered oscillator networks, such as electrical power networks. We illustrate the validity, the accuracy, and the practical applicability of our results in complex network scenarios and in smart grid applications.

16 May 2011 in Proceedings of the IEEE
Verified
Journal Article
Closed access
KTKonstantin Turitsyn
Konstantin Turitsyn
PSPetr Sulc
Petr Sulc
SBScott Backhaus
Scott Backhaus
MCMichael (Misha) Chertkov
Michael (Misha) Chertkov
High-penetration levels of distributed photovoltaic (PV) generation on an electrical distribution circuit present several challenges and opportunities for distribution utilities. Rapidly varying irradiance conditions may cause voltage sags and swells that cannot be compensated by slowly responding utility equipment resulting in a degradation of power quality. Although not permitted under current standards for interconnection of distributed generation, fast-reacting, VAR-capable PV inverters may provide the necessary reactive power injection or consumption to maintain voltage regulation under difficult transient conditions. As side benefit, the control of reactive power injection at each PV inverter provides an opportunity and a new tool for distribution utilities to optimize the performance of distribution circuits, e.g., by minimizing thermal losses. We discuss and compare via simulation various design options for control systems to manage the reactive power generated by these inverters. An important design decision that weighs on the speed and quality of communication required is whether the control should be centralized or distributed (i.e., local). In general, we find that local control schemes are able to maintain voltage within acceptable bounds. We consider the benefits of choosing different local variables on which to control and how the control system can be continuously tuned between robust voltage control, suitable for daytime operation when circuit conditions can change rapidly, and loss minimization better suited for nighttime operation.

1 January 2014 in SIAM Review
Verified
Journal Article
Closed access
DBDaniel Bienstock
Daniel Bienstock
MCMichael (Misha) Chertkov
Michael (Misha) Chertkov
SHSean Harnett
Sean Harnett
When uncontrollable resources fluctuate, optimal power flow (OPF), routinely used by the electric power industry to redispatch hourly controllable generation (coal, gas, and hydro plants) over control areas of transmission networks, can result in grid instability and, potentially, cascading outages. This risk arises because OPF dispatch is computed without awareness of major uncertainty, in particular fluctuations in renewable output. As a result, grid operation under OPF with renewable variability can lead to frequent conditions where power line flow ratings are significantly exceeded. Such a condition, which is borne by our simulations of real grids, is considered undesirable in power engineering practice. Possibly, it can lead to a risky outcome that compromises grid stability---line tripping. Smart grid goals include a commitment to large penetration of highly fluctuating renewables, thus calling to reconsider current practices, in particular the use of standard OPF. Our chance-constrained (CC) OPF co...

20 November 2014 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Open access
PSPetr Sulc
Petr Sulc
SBScott Backhaus
Scott Backhaus
MCMichael (Misha) Chertkov
Michael (Misha) Chertkov
We formulate the control of reactive power generation by photovoltaic inverters in a power distribution circuit as a constrained optimization that aims to minimize power losses subject to finite inverter capacity and upper and lower voltage limits at all nodes in the circuit. When voltage variations along the circuit are small and losses of both real and reactive powers are small compared with the respective flows, the resulting optimization problem is convex. Moreover, the cost function is separable enabling a distributed online implementation with node-local computations using only local measurements augmented with limited information from the neighboring nodes communicated over cyber channels. Such an approach lies between the fully centralized and local policy approaches previously considered. We explore protocols based on the dual-ascent method and on the alternating direction method of multipliers (ADMMs), and find that the ADMM protocol performs significantly better.

1 November 1995 in Physical Review E
Verified
Journal Article
Closed access
PDF file
MCMichael (Misha) Chertkov
Michael (Misha) Chertkov
GFGregory Falkovich
Gregory Falkovich
IKI. Kolokolov
I. Kolokolov
VLV. Lebedev
V. Lebedev
For a δ-function-correlated velocity field, simultaneous correlation functions of a passive scalar satisfy closed equations. We analyze the equation for the four-point function. To describe a solution completely, one has to solve the matching problems at the scale of the source and at the diffusion scale. We solve both the matching problems and thus find the dependence of the four-point correlation function on the diffusion and pumping scale for large space dimensionality d. It is shown that anomalous scaling appears in the first order of 1/d perturbation theory. Anomalous dimensions are found analytically both for the scalar field and for its derivatives, in particular, for the dissipation field.

1 August 2006 in Journal of Statistical Mechanics: Theory and Experiment
Verified
Journal Article
Closed access
VCVladimir Y Chernyak
Vladimir Y Chernyak
MCMichael (Misha) Chertkov
Michael (Misha) Chertkov
CJChristopher Jarzynski
Christopher Jarzynski