Scott Backhaus

Scott Backhaus

Auto-generated profile, based on publicly available information

Scott Backhaus

Materials, Physics and Applications, Los Alamos National Laboratory, Los Alamos, New Mexico United States 87545

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 May 2011 in Proceedings of the IEEE
Verified
Journal Article
Closed access
KTKonstantin Turitsyn
Konstantin Turitsyn
PSPetr Sulc
Petr Sulc
SBScott Backhaus
Scott Backhaus
MCMichael (Misha) Chertkov
Michael (Misha) Chertkov
High-penetration levels of distributed photovoltaic (PV) generation on an electrical distribution circuit present several challenges and opportunities for distribution utilities. Rapidly varying irradiance conditions may cause voltage sags and swells that cannot be compensated by slowly responding utility equipment resulting in a degradation of power quality. Although not permitted under current standards for interconnection of distributed generation, fast-reacting, VAR-capable PV inverters may provide the necessary reactive power injection or consumption to maintain voltage regulation under difficult transient conditions. As side benefit, the control of reactive power injection at each PV inverter provides an opportunity and a new tool for distribution utilities to optimize the performance of distribution circuits, e.g., by minimizing thermal losses. We discuss and compare via simulation various design options for control systems to manage the reactive power generated by these inverters. An important design decision that weighs on the speed and quality of communication required is whether the control should be centralized or distributed (i.e., local). In general, we find that local control schemes are able to maintain voltage within acceptable bounds. We consider the benefits of choosing different local variables on which to control and how the control system can be continuously tuned between robust voltage control, suitable for daytime operation when circuit conditions can change rapidly, and loss minimization better suited for nighttime operation.

20 November 2014 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Open access
PSPetr Sulc
Petr Sulc
SBScott Backhaus
Scott Backhaus
MCMichael (Misha) Chertkov
Michael (Misha) Chertkov
We formulate the control of reactive power generation by photovoltaic inverters in a power distribution circuit as a constrained optimization that aims to minimize power losses subject to finite inverter capacity and upper and lower voltage limits at all nodes in the circuit. When voltage variations along the circuit are small and losses of both real and reactive powers are small compared with the respective flows, the resulting optimization problem is convex. Moreover, the cost function is separable enabling a distributed online implementation with node-local computations using only local measurements augmented with limited information from the neighboring nodes communicated over cyber channels. Such an approach lies between the fully centralized and local policy approaches previously considered. We explore protocols based on the dual-ascent method and on the alternating direction method of multipliers (ADMMs), and find that the ADMM protocol performs significantly better.

20 November 2015 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
MLMiles Lubin
Miles Lubin
YDYury Dvorkin
Yury Dvorkin
SBScott Backhaus
Scott Backhaus
Optimal Power Flow (OPF) dispatches controllable generation at minimum cost subject to operational constraints on generation and transmission assets. The uncertainty and variability of intermittent renewable generation is challenging current deterministic OPF approaches. Recent formulations of OPF use chance constraints to limit the risk from renewable generation uncertainty, however, these new approaches typically assume the probability distributions which characterize the uncertainty and variability are known exactly. We formulate a robust chance constrained (RCC) OPF that accounts for uncertainty in the parameters of these probability distributions by allowing them to be within an uncertainty set. The RCC OPF is solved using a cutting-plane algorithm that scales to large power systems. We demonstrate the RRC OPF on a modified model of the Bonneville Power Administration network, which includes 2209 buses and 176 controllable generators. Deterministic, chance constrained (CC), and RCC OPF formulations are compared using several metrics including cost of generation, area control error, ramping of controllable generators, and occurrence of transmission line overloads as well as the respective computational performance.

9 August 2004 in Applied Physics Letters
Verified
Journal Article
Closed access
SBS. Backhaus
S. Backhaus
ETE. Tward
E. Tward
MPM. Petach
M. Petach
Traveling-wave thermoacoustic heat engines have been demonstrated to convert high-temperature heat to acoustic power with high efficiency without using moving parts. Electrodynamic linear alternators and compressors have demonstrated high acoustic-to-electric transduction efficiency as well as long maintenance-free lifetimes. By optimizing a small-scale traveling-wave thermoacoustic engine for use with an electrodynamic linear alternator, we have created a traveling-wave thermoacoustic electric generator; a power conversion system suitable for demanding applications such as electricity generation aboard spacecraft.

7 March 2011 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
SBScott Backhaus
Scott Backhaus
KTKonstantin Turitsyn
Konstantin Turitsyn
RER. E. Ecke
R. E. Ecke
We consider experimentally the instability and mass transport of flow in a Hele-Shaw geometry. In an initially stable configuration, a lighter fluid (water) is located over a heavier fluid (propylene glycol). The fluids mix via diffusion with some regions of the resulting mixture being heavier than either pure fluid. Density-driven convection occurs with downward penetrating dense fingers that transport mass much more effectively than diffusion alone. We investigate the initial instability and the quasisteady state. The convective time and velocity scales, finger width, wave number selection, and normalized mass transport are determined for 6000<Ra<90 000. The results have important implications for determining the time scales and rates of dissolution trapping of carbon dioxide in brine aquifers proposed as possible geologic repositories for sequestering carbon dioxide.

16 February 2016 in Proceedings of the IEEE
Verified
Journal Article
Closed access
IBIan Beil
Ian Beil
IHIan Hiskens
Ian Hiskens
SBScott Backhaus
Scott Backhaus
The expanding penetration of nondispatchable renewable resources within power system generation portfolios is motivating the development of demand-side strategies for balancing generation and load. Commercial heating, ventilation, and air conditioning (HVAC) loads are potential candidates for providing such demand-response (DR) services as they consume significant energy and because of the temporal flexibility offered by their inherent thermal inertia. Several ancillary services markets have recently opened up to participation by DR resources, provided they can satisfy certain performance metrics. We discuss different control strategies for providing frequency regulation DR from commercial HVAC systems and components, and compare performance results from experiments and simulation. We also present experimental results from a single ~30 000-m 2 office building and quantify the DR control performance using standardized performance criteria. Additionally, we evaluate the cost of delivering this service by comparing the energy consumed while providing DR against a counterfactual baseline.