Kenichi Nakajima

Dr. Kenichi Nakajima

orcid

Research Focus & Metrics

Academic Career Length

41Years (1986-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2015 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
WKWataru Kawakami
Wataru Kawakami
ATAkihiro Takemura
Akihiro Takemura
KYKunihiko Yokoyama
Kunihiko Yokoyama
KNKenichi Nakajima
Kenichi Nakajima
SYSyoichi Yokoyama
Syoichi Yokoyama
KKKichiro Koshida
Kichiro Koshida
Fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) is an important method for detecting tumours, planning radiotherapy treatment, and evaluating treatment responses. However, using the standardized uptake value (SUV) threshold with PET imaging may be suitable not to determine gross tumour volume but to determine biological target volume (BTV). The aim of this study was to extract internal target volume of BTV from PET images. Three spherical densities of 18F-FDG were employed in a phantom with an air or water background with repetitive motion amplitudes of 0–30 mm. The PET data were reconstructed with attenuation correction (AC) based on CT images obtained by slow CT scanning (SCS) or helical CT scanning (HCS). The errors in measured SUVmax and volumes calculated using SUV threshold values based on SUVmax (THmax) in experiments performed with varying extents of respiratory motion and AC were analysed. A partial volume effect (PVE) was not observed in spheres with diameters of ≥ 28 mm. When calculating SUVmax and THmax, using SCS for AC yielded smaller variance than using HCS (p < 0.05). For spheres of 37- and 28-mm diameters in the phantom with either an air or water background, significant differences were observed when mean THmax of 30-, 20-, or 10-mm amplitude were compared with the stationary conditions (p < 0.05). The average THmax values for 37-mm and 28-mm spheres with an air background were 0.362 and 0.352 in non-motion, respectively, and the mean THmax values for 37-mm and 28-mm spheres with a water background were 0.404 and 0.387 in non-motion and 0.244 and 0.263 in motion, respectively. When the phantom background was air, regardless of sphere concentration or size, THmax was dependent only on motion amplitude. We found that there was no PVE for spheres with ≥ 28-mm diameters, and differences between SUVmax and THmax were reduced by using SCS for AC. In the head-and-neck and the abdomen, the standard values of THmax were 0.25 and 0.40 with and without respiratory movement, respectively. In the lungs, the value of THmax became the approximate expression depending on motion amplitude.

10 October 2007 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Closed access
PDF file
TNTsunehiko Nishimura
Tsunehiko Nishimura
KNKenichi Nakajima
Kenichi Nakajima
HKHideo Kusuoka
Hideo Kusuoka
AYAkira Yamashina
Akira Yamashina
SNShigeyuki Nishimura
Shigeyuki Nishimura

19 June 2014 in Journal of Nuclear Cardiology
Verified
Journal Article
Open access
PDF file
KNKenichi Nakajima
Kenichi Nakajima
KOKoichi Okuda
Koichi Okuda
MYMana Yoshimura
Mana Yoshimura
SMShinro Matsuo
Shinro Matsuo
HWHiroshi Wakabayashi
Hiroshi Wakabayashi
SKSeigo Kinuya
Seigo Kinuya
The heart-to-mediastinum ratio (HMR) of 123I-metaiodobenzylguanidine (MIBG) showed variations among institutions and needs to be standardized among various scinticamera-collimator combinations.

31 January 2020 in Journal of Movement Disorders
Verified
Journal Article
Open access
PDF file
MYMasahito Yamada
Masahito Yamada
JKJunji Komatsu
Junji Komatsu
KNKeiko Nakamura
Keiko Nakamura
KSKenji Sakai
Kenji Sakai
MSMiharu Samuraki-Yokohama
Miharu Samuraki-Yokohama
MYMitsuhiro Yoshita
Mitsuhiro Yoshita
The aim of this article is to describe the 2017 revised consensus criteria for the clinical diagnosis of dementia with Lewy bodies (DLB) with future directions for the diagnostic criteria. The criteria for the clinical diagnosis of probable and possible DLB were first published as the first consensus report in 1996 and were revised in the third consensus report in 2005. After discussion at the International DLB Conference in Fort Lauderdale, Florida, USA, in 2015, the International DLB Consortium published the fourth consensus report including the revised consensus criteria in 2017. The 2017 revised criteria clearly distinguish between clinical features and diagnostic biomarkers. Significant new information about previously reported aspects of DLB has been incorporated, with increased diagnostic weighting given to rapid eye movement (REM) sleep behavior disorder (RBD) and iodine-123-metaiodobenzylguanidine (MIBG) myocardial scintigraphy. Future directions include the development of the criteria for early diagnosis (prodromal DLB) and the establishment of new biomarkers that directly indicate Lewy-related pathology, including α-synuclein imaging, biopsies of peripheral tissues (skin, etc.) for the demonstration of α-synuclein deposition, and biochemical markers (cerebrospinal fluid/blood), as well as the pathological evaluation of the sensitivity and specificity of the 2017 revised diagnostic criteria. In conclusion, the revised consensus criteria for the clinical diagnosis of DLB were reported with the incorporation of new information about DLB in 2017. Future directions include the development of the criteria for early diagnosis and the establishment of biomarkers directly indicative of Lewy-related pathology.

20 February 2016 in Annals of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
KNKenichi Nakajima
Kenichi Nakajima
NMNaoya Matsumoto
Naoya Matsumoto
TKTokuo Kasai
Tokuo Kasai
SMShinro Matsuo
Shinro Matsuo
KKKeisuke Kiso
Keisuke Kiso
KOKoichi Okuda
Koichi Okuda
As a 2-year project of the Japanese Society of Nuclear Medicine working group activity, normal myocardial imaging databases were accumulated and summarized. Stress-rest with gated and non-gated image sets were accumulated for myocardial perfusion imaging and could be used for perfusion defect scoring and normal left ventricular (LV) function analysis. For single-photon emission computed tomography (SPECT) with multi-focal collimator design, databases of supine and prone positions and computed tomography (CT)-based attenuation correction were created. The CT-based correction provided similar perfusion patterns between genders. In phase analysis of gated myocardial perfusion SPECT, a new approach for analyzing dyssynchrony, normal ranges of parameters for phase bandwidth, standard deviation and entropy were determined in four software programs. Although the results were not interchangeable, dependency on gender, ejection fraction and volumes were common characteristics of these parameters. Standardization of 123I-MIBG sympathetic imaging was performed regarding heart-to-mediastinum ratio (HMR) using a calibration phantom method. The HMRs from any collimator types could be converted to the value with medium-energy comparable collimators. Appropriate quantification based on common normal databases and standard technology could play a pivotal role for clinical practice and researches.

1 February 2011 in Journal of Nuclear Cardiology
Verified
Journal Article
Closed access
PDF file
KOKoichi Okuda
Koichi Okuda
KNKenichi Nakajima
Kenichi Nakajima
THTetsuo Hosoya
Tetsuo Hosoya
TITakehiro Ishikawa
Takehiro Ishikawa
TKTakahiro Konishi
Takahiro Konishi
SKSeigo Kinuya
Seigo Kinuya