Verina Logito

Dr. Verina Logito

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 April 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
AIAgnes Rengga Indrati
Agnes Rengga Indrati
FKFelicia Nathania Kosasih
Felicia Nathania Kosasih
FFFitri Fadhilah
Fitri Fadhilah
APAmelia Pratiwi
Amelia Pratiwi
UMUmmi Muthiah
Ummi Muthiah
RWRudi Wisaksana
Rudi Wisaksana
Approximately 10–35% of people living with HIV (PLHIV) on antiretroviral therapy (ART) fail to restore CD4+ T cell counts, a state known as immunological non-responder (INR) characterized by persistent immune activation and elevated cytokine levels. Objective: This study aimed to identify cytokines that can serve as biomarkers for immune activation and inflammation in INR patients. Methods: We conducted a cross-sectional study comparing two groups: INRs (PLHIV on ART with viral suppression) and immunological responders (IRs). We analyzed 40 samples of virologically suppressed PLHIV, measuring CD4+ T cell counts, viral load via RT-PCR, and cytokine levels through cytometric bead array (CBA). Results: The INR group exhibited significantly higher median serum levels of IL-6 (1.74 pg/mL vs. 0.94 pg/mL, p = 0.016) and IL-10 (1.65 pg/mL vs. 0.92 pg/mL, p = 0.03) compared to the IR group. Conclusions: Elevated IL-6 and IL-10 levels may serve as potential markers to distinguish INR from IR patients with areas under the curve (AUC) of 0.731 and 0.707, respectively.

1 April 2023 in Open Access Rheumatology: Research and Reviews
Verified
Journal Article
Open access
PDF file
VLVerina Logito
Verina Logito
ATAnna Tjandrawati
Anna Tjandrawati
ASAdhi Kristianto Sugianli
Adhi Kristianto Sugianli
NTNina Tristina
Nina Tristina
SDSumartini Dewi
Sumartini Dewi
Purpose: Systemic Sclerosis related Interstitial Lung Disease (SSc-ILD) is the most common clinical manifestation of SSc with a high morbidity and mortality rate. However, the Thorax High-Resolution Computed Tomography (HCRT) as the gold standard diagnostic tool for SSc-ILD is not widely equipped in health-care facilities. Recently, specific autoantibody examination (anti-topoisomerase-1 (ATA), anti-Th/To antibody, and anti-fibrillarin) has been studied and used for SSc-ILD diagnosis. This study aims to evaluate the diagnostic performance of specific autoantibody examination among SSc-ILD. Patients and Methods: This retrospective study reviews data from local dedicated SSc database (Sclerosis Systemic Register System Development Electronic Medical Record) which were collected between March 2019 and August 2021. Population of this study include adult inpatients and outpatients at Dr. Hasan Sadikin General Hospital, who have been diagnosed with SSc based on ACR/EULAR 2013 criteria, which met inclusion and exclusion criteria. The SSc patients were grouped into SSc-ILD and SSc non-ILD based on HRCT and tested for SSC-ILD specific autoantibody test (ATA, anti-Th/To antibody, and anti-fibrillarin) to obtain the diagnostic performance (sensitivity, specificity, and positive- and negative-predictive value). Results: A total of 74 subject grouped into 47 SSc-ILD and 27 SSc-non ILD patients. ATA validity test results showed 85.1% sensitivity, 19.2% specificity, 65.6% PPV, and 41.7% NPV. Anti-Th/To antibody obtained 27.7% sensitivity, 88.9% specificity, 81.3% PPV, and 41.4% NPV. The anti-fibrillarin validity test result showed a 12.8% sensitivity, 96.3% specificity, 85.7% PPV, and 38.8% NPV. The combination of the three parameters had 95.7% sensitivity, 18.5% specificity, 67.1% PPV, and 71.4% NPV. Conclusion: The combination of the SSc-ILD specific autoantibody test and HCRT is expected to detect all affected patients. Based on these results, SSc-ILD autoantibody-specific test can be used as an alternative examination for screening and diagnosis in health-care facilities that are not equipped with HRCT.

1 September 2021 in Majalah Kedokteran Bandung
Verified
Journal Article
Open access
PDF file
DTDewi Kartika Turbawaty
Dewi Kartika Turbawaty
VLVerina Logito
Verina Logito
ATAnna Tjandrawati
Anna Tjandrawati
Methicillin-Resistant Staphylococcus aureus (MRSA) in the hospital is found mainly in surgical patients, which increases morbidity and mortality. Currently, vancomycin is the drug of choice for the treatment of MRSA infections. The increasing use of vancomycin and its inappropriate administration may increase the resistance of S. aureus to vancomycin. This study aimed to describe the distribution of MRSA and types of antibiotics that are still sensitive to MRSA in surgical and non-surgical patients. This cross-sectional, observational, retrospective descriptive study was conducted at the Microbiology Laboratory, Dr. Hasan Sadikin General Hospital, in 2019 using secondary data on the results of culture examination and antibiotic susceptibility of positive S. aureus culture isolates from all types of isolates from surgical and non-surgical patients. All specimens were cultured in appropriate media. Identification of S. aureus was performed by Gram staining to identify bacterial morphology, and automatic tools. Antibiotic susceptibility test was performed using an automatic machine. Seventy-five isolates (17%) were identified to be MRSA with 46 (53%) of them retrieved from surgical patients. Most of the MRSA isolates came from pus and were mostly due to skin infections. Antibiotic susceptibility results showed two Vancomycin-Resistant Staphylococcus aureus (VRSA) isolates from surgical patients. The positive culture of the MRSA and VRSA was dominated by surgical patients with pus coming from surgical wound infection, burn, and other skin infection as the most common sources. Thus, the proportion of MRSA isolates in the hospital in 2019 is 17% and two VRSA isolates are identified in the same year. The surgical ward was the primary origin of most MRSA isolates. Further studies are necessary to identify the MRSA incidence rate, evaluation and periodic monitoring of antibiotic use, and active surveillance in the surgical patient rooms.

1 March 2024 in Medical Devices: Evidence and Research
Verified
Journal Article
Open access
PDF file
AIAgnes Rengga Indrati
Agnes Rengga Indrati
Luhung BudiailmiawanLuhung Budiailmiawan
Luhung Budiailmiawan
LMLouisa Markus
Louisa Markus
JJJohanis Johanis
Johanis Johanis
VLVerina Logito
Verina Logito
ARAryati
Aryati
Introduction: Laboratory examination is extremely important in handling the COVID-19 pandemic. In the first era of the pandemic, the molecular and antigen tests were limited. Hence, at that time, it was necessary to carry out antibody Rapid Diagnostic Tests (RDT). However, many antibody RDTs were yet to obtain Food and Drug Authorization (FDA)’s approval. Purpose: Therefore, The Indonesian Association of Clinical Pathology and Medical Laboratory (PDS PatKLIn) decided to conduct a validity test of RDT antibodies to find out the quality of SARS-CoV-2 diagnosis performance based on these RDTs used. Patient and Methods: This is a descriptive observational design with diagnostic analysis. The retrospective secondary data were collected from 34 provinces in Indonesia from May to June 2020. Data analysis was carried out on the sensitivity and specificity values of each antibody RDT brand to the RT-PCR result and analyzed descriptive data. Results: The amount of secondary data of antibody RDT and RT-PCR results collected was 139,908, consisting of 59 RDT brands of which 44% were authorized by The Indonesian COVID-19 Response Acceleration Task Force (Gugus Tugas Percepatan Penanganan COVID-19 Indonesia). There were huge variations of SARS-CoV-2 antibody RDT performance between total antibody types (sensitivity 59.18%, specificity 62%), IgM RDT (sensitivity 16– 100%, specificity 7– 97%), and RDT IgG (sensitivity 33– 96%, specificity 19– 100%). Conclusion: The variations in the RDT antibodies’performance can cause errors in diagnosis leading to significant material and immaterial losses. Therefore, cooperation from various parties is needed for the pre- and post-marketing surveillance process to assess the performance and the characteristics of each RDT kit and other diagnostic methods to assist the rapid pandemic response process.

1 July 2024 in International Journal of General Medicine
Verified
Journal Article
Open access
PDF file
DTDewi Kartika Turbawaty
Dewi Kartika Turbawaty
ASAndy Sudjadi
Andy Sudjadi
LLLeni Lismayanti
Leni Lismayanti
TRTiene Rostini
Tiene Rostini
VLVerina Logito
Verina Logito
Introduction: Corona Virus Disease-19 (COVID-19) is a disease caused by Severe-Acute-Respiratory-Syndrome-Coronavirus-2 (SARS-CoV-2). The most reliable and widely accepted method for diagnosing this infection, despite facing various challenges, is the Reverse Transcription Polymerase Chain Reaction (RT-PCR) method, which utilizes nasopharyngeal swab sample. Reverse-transcription loop mediated isothermal amplification (RT-LAMP) is a simpler nucleic acid amplification method compared to the RT-PCR method. This method has several advantages, including: of amplification at constant temperature, faster results, and potentially greater examination capacity. Purpose: This study aimed to compare the validity of the RT-LAMP method using saliva specimens with that of the RT-PCR method using nasopharyngeal smears. Methods: This was an analytical observational study with a cross-sectional design. The participants were inpatients in the COVID-19 special isolation building of Hasan Sadikin General Hospital, Indonesia with a probable (clinical symptoms of covid, but not confirm NAAT examination) or confirmed diagnosis of COVID-19 from September 2021 to February 2022. The inclusion criteria are COVID-19 patients with symptoms, adult subjects, and composite mentions. Patients who were unable to secrete saliva were also excluded. Results: In total, 118 specimens were collected. The validity test results of the saliva specimens using the RT-LAMP method showed sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV), of 65.5%, 100%, 100%, and 75%, respectively. The results increased in subjects treated between 3 and 7 days after symptom onset ie 73.2%, 100%, 100%, and 82.3%, respectively. Conclusion: The very strong specificity accompanied by good sensitivity and NPV in the group of subjects treated 3– 7 days after the onset of symptoms indicates that the RT-LAMP method using saliva specimens can be an efficient and reliable alternative tool in detecting the SARS-CoV-2 virus.

29 August 2021 in Biomedical Research and Therapy
Verified
Journal Article
Open access
PDF file
ATAnna Tjandrawati
Anna Tjandrawati
VLVerina Logito
Verina Logito
WSWinda Agnestia Maranna Saragih
Winda Agnestia Maranna Saragih
ARAndri Reza Rahmadi
Andri Reza Rahmadi
SDSumartini Dewi
Sumartini Dewi
Background: Interstitial lung disease (ILD) is a complication often found in patients with Systemic Sclerosis (SSc). This usually manifests as pulmonary fibrosis and is the leading cause of death in SSc patients. Antinuclear antibodies indirect immunofluorescence (ANA-IIF) test and specific autoantibodies testing could be employed as a diagnostic marker to detect pulmonary fibrosis, but the high cost of these tests often burdens patients in developing countries. This study aims to compare ANA-IIF and an alternative, possibly inexpensive method to detect pulmonary fibrosis in SSc. Methods: This is a preliminary study prior to the cohort systemic sclerosis registry conducted in Rheumatology Outpatient Clinic and Clinical Pathology Department at Dr. Hasan Sadikin General Hospital, Bandung, from January 1, 2018 to December 31, 2020. Two contrastive laboratory testing strategies were followed to confirm pulmonary fibrosis in 61 SSc patients. The first strategy was to perform antinuclear antibodies indirect immunofluorescence (ANA-IIF) test followed by specific autoantibodies detection [anti-topoisomerase-I (ATA), Anti-Th/To, SSc Profile, Immunoblot]. The alternative strategy included conducting the tests for SSc autoantibodies in the reverse order. Results: A total of 42 out of 61 (68.8%) subjects were diagnosed with pulmonary fibrosis by high-resolution computed tomography (HRCT) scan. The first strategy detected dominant specific pulmonary fibrosis autoantibodies in subjects with pulmonary fibrosis: homogeneous nucleolar pattern was dominant (n = 25, 59.52%), followed by nucleolar pattern (n = 17, 40.48%). Of all the subjects with a homogeneous nucleolar pattern, ATA was detected in 15 subjects (60%), the combination of ATA and Th/To in 9 subjects (36%), and Ro52 in one subject (4%). The second strategy yielded positive autoantibodies results in 29 out of 42 (69.05%) subjects, ATA in 20 subjects (47.61%), and Th/To in 9 patients (21.44%), but failed to detect any autoantibodies specific to SSc-ILD in 13 subjects (30.95%). Conclusion: The first strategy [ANA-IIF followed specific autoantibodies testing (ATA, Th/To, SSc profile and immunoblot)] is more likely to detect specific autoantibodies toward ILD in SSc patients.