Diana Zakarkaite

Dr. Diana Zakarkaite

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
EOEustaquio Maria Onorato
Eustaquio Maria Onorato
FAFrancesco Alamanni
Francesco Alamanni
MMManuela Muratori
Manuela Muratori
GSGrzegorz Smolka
Grzegorz Smolka
WWWojtek Wojakowski
Wojtek Wojakowski
ABAntonio Luca Bartorelli
Antonio Luca Bartorelli
Between December 2014 and March 2021, 144 patients with aortic (Ao) or mitral (Mi) paravalvular leaks (PVLs) were enrolled at 21 sites in 10 countries. Safety data were available for 137 patients, who were included in the safety analysis fraction (SAF), 93 patients with Mi PVLs and 44 patients with Ao PVLs. The full analysis set (FAS) comprised 112 patients with available stratum (aortic/mitral leak) as well as baseline (BL), 180-day or later assessments (2 years). Procedural success (implantation of the device with a proper closure of the PVL, defined as reduction in paravalvular regurgitation of ≥one grade as assessed by echocardiography post implantation) was achieved in 91.3% of FAS patients with Mi PVLs and in 90.0% of those with Ao PVLs. The proportion of patients suffering from significant or severe heart failure (HF), classified as New York Heart Association (NYHA) class III/IV, decreased from 80% at baseline to 14.1% at 2-year follow-up (FAS). The proportion of FAS patients needing hemolysis-related blood transfusion decreased from 35.5% to 3.8% and from 8.1% to 0% in Mi patients and Ao patients, respectively. In total, 35 serious adverse events (SAEs) were reported in 27 patients (19.7%) of the SAF population. The SAEs considered possibly or probably related to the device included device embolization (three patients), residual leak (two patients) and vascular complication (one patient). During follow-up, 12/137 (8.8%) patients died, but none of the deaths was considered to be device-related. Patients implanted with the Occlutech Paravalvular Leak Device (PLD) showed long-lasting improvements in clinical parameters, including NYHA class and a reduced dependency on hemolysis-related blood transfusions.

1 June 2025 in Stroke
Verified
Journal Article
Open access
JPJukka Putaala
Jukka Putaala
NMNicolas Nicolas Martinez-Majander
Nicolas Nicolas Martinez-Majander
MLMichelle Leppert
Michelle Leppert
LTLauri Tulkki
Lauri Tulkki
JPJani Pirinen
Jani Pirinen
SGSECRETO Study Group
SECRETO Study Group
BACKGROUND: The incidence of young-onset ischemic stroke is rising, driven by cryptogenic ischemic stroke (CIS) and patients without vascular risk factors. This study examines the burden and associations of modifiable traditional, nontraditional, and female sex–specific risk factors with young-onset CIS, stratified by clinically relevant patent foramen ovale (PFO), defined by high-risk features of atrial septal aneurysm or large right-to-left shunt. METHODS: We enrolled consecutive patients aged 18 to 49 years with recent CIS and frequency-matched stroke-free controls of the same age and sex from 19 European sites. Logistic regression assessed the association of risk factor counts (12 traditional, 10 nontraditional, 5 female sex–specific) and individual risk factors, stratified by PFO. Analyses were stratified by sex and age (18–39 and 40–49 years), with computation of population-attributable risk. RESULTS: We included 523 patients (median age, 41 years; 47.3% women; 196 [37.5%] with PFO) and 523 controls. In patients with CIS without PFO, each additional traditional (odds ratio, 1.417 [95% CI, 1.282–1.568]), nontraditional (odds ratio, 1.702 [95% CI, 1.338–2.164]), and female sex–specific risk factor (odds ratio, 1.700 [95% CI, 1.107.1–2.611]) increased CIS risk. For patients with CIS with PFO, each traditional risk factor increased the risk (odds ratio, 1.185 [1.057–1.328]), but only nontraditional risk factors remained significant when fully adjusted (odds ratio, 2.656 [2.036–3.464]). Population-attributable risks for CIS without PFO were 64.7%, 26.5%, and 18.9% for traditional, nontraditional, and female sex–specific risk factors. For CIS with PFO, population-attributable risks were 33.8%, 49.4%, and 21.8%, respectively. Migraine with aura was the most significant contributor, with population-attributable risks of 45.8% for CIS with PFO and 22.7% for CIS without PFO, showing a stronger impact in women. CONCLUSIONS: Despite the initial cryptogenic label of these strokes, traditional risk factors significantly contribute to CIS without PFO, while nontraditional factors seem more critical for CIS with PFO. Migraine with aura plays a prominent role in young-onset CIS development, particularly in women. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01934725.

30 July 2012 in Cardiovascular Ultrasound
Verified
Journal Article
Open access
PDF file
JČJelena Čelutkienė
Jelena Čelutkienė
DZDiana Zakarkaite
Diana Zakarkaite
VSViktor Skorniakov
Viktor Skorniakov
VZVida Zvironaite
Vida Zvironaite
VGVirginija Grabauskiene
Virginija Grabauskiene
ALAleksandras Laucevičius
Aleksandras Laucevičius
A number of myocardial Doppler-derived velocity, strain myocardial imaging parameters (DMI) and speckle tracking imaging (STI) have been proposed for the quantification of myocardial ischemia during stress echocardiography. The purpose of the study was to identify the best single ultrasound quantitative parameter for prediction of significant coronary stenosis and compare it with visual assessment during dobutamine stress echocardiography (DSE).

28 February 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AZAleksejus Zorinas
Aleksejus Zorinas
DZDiana Zakarkaite
Diana Zakarkaite
VJVilius Janušauskas
Vilius Janušauskas
Donatas AustysDonatas Austys
Donatas Austys
LPLina Puodziukaite
Lina Puodziukaite
EOEustaquio Maria Onorato
Eustaquio Maria Onorato
Widespread catheter-based interventions for structural heart disease have overtaken the treatment of paravalvular leaks (PVL). Multimodality imaging techniques play a crucial role in accurate diagnosis, procedure planning and performance. However, PVL closure is often technically challenging due to the complex anatomy of the defects and their relation to surrounding anatomical structures. The application of echocardiography and fluoroscopy imaging fusion (EFF) may simplify challenging imaginative three-dimensional reconstruction of the intracardiac anatomy and facilitate the procedure. To master new technology, personnel must make cognitive changes, overcome a learning curve, and obtain adequate theoretical knowledge. Main aim of this manuscript is to present basic recommendations for EFF application in practice, alongside, each scenario is supported by technically challenging clinical examples. We may conclude that our manuscript may provide useful information for physicians on EEF application in clinical practice.

28 May 2011 in Cardiovascular Ultrasound
Verified
Journal Article
Open access
PDF file
ESEgle Sadauskiene
Egle Sadauskiene
DZDiana Zakarkaite
Diana Zakarkaite
LRLigita Ryliskyte
Ligita Ryliskyte
JČJelena Čelutkienė
Jelena Čelutkienė
ARAlfredas Rudys
Alfredas Rudys
ALAleksandras Laucevicius
Aleksandras Laucevicius
The study was designed to evaluate whether the preserved coronary flow reserve (CFR) 72 hours after reperfused acute myocardial infarction (AMI) is associated with less microvascular dysfunction and is predictive of left ventricular (LV) functional recovery and the final infarct size at follow-up.

25 October 2024 in Journal of the American Heart Association
Verified
Journal Article
Open access
JPJukka Putaala
Jukka Putaala
BSBettina von Sarnowski
Bettina von Sarnowski
USUlf Schminke
Ulf Schminke
RBRaila Busch
Raila Busch
NMNicolas Nicolas Martinez-Majander
Nicolas Nicolas Martinez-Majander
TGthe SECRETO Study Group
the SECRETO Study Group