Trey Naylor

Mr. Trey Naylor

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2025 in International Journal of Exercise Science
Verified
Journal Article
Open access
PDF file
TNTrey Naylor
Trey Naylor
MJMariana Victoria Jacobs
Mariana Victoria Jacobs
MTMichael C. Taylor
Michael C. Taylor
JCJody Clasey
Jody Clasey
There is currently an exponential increase in the prevalence of childhood obesity thus warranting the demand to appropriately measure and evaluate cardiorespiratory fitness within educational settings. The aims of this study were to (1) compare measured peak oxygen consumption (VO2peak), heart rate peak (HRpeak), and 1-min heart rate recovery (HRRec) responses obtained using a GXTmax and the PACER test; and (2) compare the VO2peak from the GXTmax and PACER test to a PACER prediction equation (ScottEqua). Methods: This study included 32 (16 boys) children. Despite not having maturational assessments on these children, we limited the subject’s age range from 10-11 year old’s to decrease the possibility of including additional variability in pubertal status. The participants were classified by body mass index for age and sex percentiles (BMI%) as Healthy-Weight (HW BMI% ≤ 85th percentile) or At-Risk (AR BMI% > 85th percentile). Participants completed the GXTmax and PACER tests while wearing a portable metabolic system to measure VO2peak; and these measures were compared to the estimated VO2peak using the ScottEqua. Group mean differences and correlation analysis were used to compare the testing and predictive procedures. Results: We found no significant differences between the GXTmax and PACER VO2peak; however, the Scott Equa VO2peak was significantly greater than these measures. HRpeak was significantly greater during the GXTmax; but no significant HRRec were found. Conclusions: The PACER and GXTmax provide similar VO2peak measures; however, PACER prediction equations should be used with caution in children 10-11 years.

22 April 2025 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
TNTrey Naylor
Trey Naylor
MJMariana Victoria Jacobs
Mariana Victoria Jacobs
CECameron J. Elder
Cameron J. Elder
Michael SamaanMichael Samaan
Michael Samaan
JCJody L. Clasey
Jody L. Clasey
Purpose: The purpose of this study was to determine the intra- and interrater reliability of quadriceps and hamstring soft tissue measures using DXA scans. Methods: A total of 44 subjects (23 males) participated in this study. The first total body DXA scan was performed in the standard anterior/posterior scanning position, followed by two additional total body scans while the subjects were lying on their left and right sides with the leg of interest extended and the contralateral leg bent. Unique regions of interest were created for analyses of mineral-free lean masses (MFL) using custom analysis software with manual tracing (by two investigators) of the quadriceps (QUADS) and hamstrings (HAMS) of the right and left thighs. Between–within repeated measure analysis of variance (ANOVA) was used to determine if there were significant differences among the MFL measures, while intraclass correlation coefficients (ICC) and coefficients of variation (CV) were used to assess the intra- and interrater reliability. Results: Between-group analyses revealed that Investigator 2 had small yet significantly higher mean differences for right QUADS (2346.6 ± 602.4 g vs. 2327.4 ± 587.9 g), left QUADS (2337.3 ± 581.9 g vs. 2312.8 ± 581.2 g), right HAMS (2655.9 ± 626.3 g vs. 2543.0 ± 593.5 g), and left HAMS (2686.1 ± 628.1 g vs. 2562.8 ± 596.5 g) when compared to Investigator 1. Intraclass correlation coefficients between (≥0.984) and within (≥0.992) raters were high for all MFL measures, with low variation across all MFL measures (≤1.62%). Conclusions: Despite having significant group mean differences, our results revealed strong and significant reliability, and we recommend that a single investigator analyze the scans twice and that the mean of the two measures be used for final reporting within a given study.

14 September 2026 in Medicine & Science in Sports & Exercise
Verified
Journal Article
Closed access
TNTrey Naylor
Trey Naylor
ASAbigayle R. Spong
Abigayle R. Spong
SSScott M. Sigrist
Scott M. Sigrist
KKKelsie P. Kohlman
Kelsie P. Kohlman
JCJody L. Clasey
Jody L. Clasey
Was not provided for this article.

25 October 2025 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
TNTrey Naylor
Trey Naylor
MJMariana Victoria Jacobs
Mariana Victoria Jacobs
Michael SamaanMichael Samaan
Michael Samaan
LMLaura C. Murphy
Laura C. Murphy
DSDouglas J. Schneider
Douglas J. Schneider
JCJody L. Clasey
Jody L. Clasey
This study aimed to (1) demonstrate the intra- and interrater reliability of quadriceps (QUADS) and hamstring (HAMS) mineral-free lean (MFL) mass measures using DXA scanning, (2) determine the association of total thigh MFL mass measures with MFL mass measures of the hamstrings and quadriceps combined and (3) analyze the association between total thigh MFL mass and total body MFL mass measures. A total of 80 young children (aged 5 to 11 yrs) participated and unique regions of interest were created using custom analysis software with manual tracing of the QUADS, HAMS, and total thigh MFL mass measures. Repeated-measure analysis of variance was used to determine if there were significant differences among the MFL measures while intraclass correlation coefficients (ICC), coefficients of variation (CV), and regression analysis were used to determine the intra- and interrater reliability and the explained variance in the association among MFL mass measures. The right interrater QUADS MFL mass was the only significant group mean difference, and ICCs between (≥0.961) and within (≥0.919) raters were high for all MFL measures with low variation across all MFL measures (≤6.13%). The explained variance was 92.5% and 96.3% for the between-investigator analyses of the right and left total thigh MFL mass measures, respectively. Furthermore, 97.5% of the variance in total body MFL mass was explained by the total thigh MFL mass. DXA MFL mass measures of the QUADS, HAMS and total thigh can be confidently used in young children and may provide an alternative to CT or MRI scanning when assessing changes in MFL cross-sectional area or volume measures due to disease progression, training and rehabilitative strategies.