BACKGROUND: The circadian system entrains behavioral and physiological rhythms to environmental cycles, and modern lifestyles disrupt this entrainment. We investigated a timed exercise intervention to phase shift the internal circadian rhythm. METHODS: In 52 young, sedentary adults, dim light melatonin onset (DLMO) was measured before and after 5 days of morning (10 hours after DLMO; n = 26) or evening (20 hours after DLMO; n = 26) exercise. Phase shifts were calculated as the difference in DLMO before and after exercise. RESULTS: Morning exercise induced phase advance shifts (0.62 ± 0.18 hours) that were significantly greater than phase shifts from evening exercise (–0.02 ± 0.18 hours; P = 0.01). Chronotype also influenced the effect of timed exercise. For later chronotypes, both morning and evening exercise induced phase advances (0.54 ± 0.29 hours and 0.46 ±0.25 hours, respectively). In contrast, earlier chronotypes had phase advances from morning exercise (0.49 ± 0.25 hours) but had phase delays from evening exercise (–0.41 ± 0.29 hours). CONCLUSION: Late chronotypes — those who experience the most severe circadian misalignment — may benefit from phase advances induced by exercise in the morning or evening, but evening exercise may exacerbate circadian misalignment in early chronotypes. Thus, personalized exercise timing prescription, based on chronotype, could alleviate circadian misalignment in young adults. TRIAL REGISTRATION: Trial registration can be found at www.clinicaltrials.gov (NCT04097886). FUNDING: Funding was supplied by NIH grants UL1TR001998 and TL1TR001997, the Barnstable Brown Diabetes and Obesity Center, the Pediatric Exercise Physiology Laboratory Endowment, the Arvle and Ellen Turner Thacker Research Fund, and the University of Kentucky.
Circadian rhythms differ between young adult males and females. For example, males tend to be later chronotypes, preferring later timing of sleep and activity, than females. Likewise, there are sex differences in body composition and cardiorespiratory fitness. Few studies have investigated the association between circadian rhythms, cardiorespiratory fitness, and body composition. We sought to determine whether chronotype and circadian phase were associated with cardiorespiratory fitness, body composition, and anthropometric measures in sedentary males and females. Fifty‐nine adults participated in the study. Circadian phase and chronotype were measured using dim light melatonin onset (DLMO) and the Morningness–Eveningness Questionnaire (MEQ) score. We used peak oxygen uptake (VO2peak) results from a maximal graded exercise test to assess cardiorespiratory fitness. Body composition, BMI, and circumferences were collected as markers of adiposity. We observed a sex difference in the association between DLMO and VO2peak. For males, a later DLMO was associated with a lower VO2peak. VO2peak did not vary based on DLMO in females. Later circadian phase was also associated with increased body fat percentage, fat mass index, and abdominal circumference in males, but not females. Collectively, these results suggest that males who are later chronotypes may be at risk of obesity and low cardiorespiratory fitness.
Purpose: The purpose of this study was to determine the intra- and interrater reliability of quadriceps and hamstring soft tissue measures using DXA scans. Methods: A total of 44 subjects (23 males) participated in this study. The first total body DXA scan was performed in the standard anterior/posterior scanning position, followed by two additional total body scans while the subjects were lying on their left and right sides with the leg of interest extended and the contralateral leg bent. Unique regions of interest were created for analyses of mineral-free lean masses (MFL) using custom analysis software with manual tracing (by two investigators) of the quadriceps (QUADS) and hamstrings (HAMS) of the right and left thighs. Between–within repeated measure analysis of variance (ANOVA) was used to determine if there were significant differences among the MFL measures, while intraclass correlation coefficients (ICC) and coefficients of variation (CV) were used to assess the intra- and interrater reliability. Results: Between-group analyses revealed that Investigator 2 had small yet significantly higher mean differences for right QUADS (2346.6 ± 602.4 g vs. 2327.4 ± 587.9 g), left QUADS (2337.3 ± 581.9 g vs. 2312.8 ± 581.2 g), right HAMS (2655.9 ± 626.3 g vs. 2543.0 ± 593.5 g), and left HAMS (2686.1 ± 628.1 g vs. 2562.8 ± 596.5 g) when compared to Investigator 1. Intraclass correlation coefficients between (≥0.984) and within (≥0.992) raters were high for all MFL measures, with low variation across all MFL measures (≤1.62%). Conclusions: Despite having significant group mean differences, our results revealed strong and significant reliability, and we recommend that a single investigator analyze the scans twice and that the mean of the two measures be used for final reporting within a given study.
Recommendations for endurance exercise prescription are often based on percentages of heart rate (HR) or the volume of oxygen consumption (O2) maximum or reserve that is extrapolated to a power output (P) or velocity. Previous work has demonstrated dissociations of the expected responses to exercise anchored to the critical heart rate (CHR) compared with the P associated with CHR. However, it is unclear if similar dissociations due to reductions in P to maintain the designated intensity would be present during exercise anchored to the O2 associated with CHR (O2CHR). The purpose of this study was to examine the patterns in physiological (O2, HR, P, respiration rate [RR], muscle oxygen saturation [%SmO2]), neuromuscular (electromyographic and mechanomyographic amplitude [EMG AMP, MMG AMP], mean power frequency [EMG MPF, MMG MPF]), and perceptual (rating of perceived exertion [RPE]) responses during exercise at O2CHR (O2-clamp). On separate days, ten participants (age: 25 ± 4 yr) performed a graded exercise test and four constant P trials at 85–100% of peak P (PP) to derive CHR and O2CHR. Responses were recorded during a trial to exhaustion at O2CHR (32.86 ± 7.12 mL·kg−1·min−1; TLim = 31.31 ± 21.37 min) and normalized in 10% intervals of TLim to their respective values at PP. The one-way repeated-measures ANOVA with post hoc, Bonferroni-corrected, pairwise comparisons indicated differences (p < 0.001) from baseline for HR (mean ± SD %change = 8 ± 3%), RR (43 ± 38%), P (−15 ± 5%), EMG MPF (10 ± 8%), and RPE (65 ± 38%), but no differences (p = 0.077–0.955) for %SmO2 (−17 ± 53%), EMG AMP (−3 ± 16%), MMG AMP (40 ± 61%), and MMG MPF (1 ± 7%). The loss in performance observed during O2-Clamp exercise may provide a quantification of the inefficiency associated with the O2 slow component phenomenon. The neuromuscular responses suggested constant muscle excitation despite the reductions in P, but the metabolic and perceptual responses suggested a combination of feedforward and feedback mechanisms regulating TLim. Future studies should further examine responses to the O2-Clamp exercise at a uniform threshold.
Introduction: This study compared physiological and subjective measures resulting from maximal graded exercise testing (GXTmax) when the traditional Bruce protocol and a protocol designed specifically for pediatric populations (Pediatric Exercise Physiology (PEP) Lab protocol) were employed in children of varying adiposities. Methods: Participants included 48 children (24 males, 24 females; ages 7–11 yr). GXTmax variables of interest included peak oxygen consumption (V·O2peak), peak heart rate (HRpeak), peak systolic blood pressure (SBPpeak), peak respiratory exchange ratio (RERpeak), and protocol duration. Participants were also asked to subjectively determine which GXTmax they perceived as more difficult. Results: Comparing the whole group, there were no significant differences in V·O2peak or HRpeak between protocols; however, the PEP Lab GXTmax produced significantly greater SBPpeak and significantly lower RERpeak. All physiological variables were moderately or strongly associated between the two protocols (explained variance ranged from 23.9% to 68.5%). In addition, 87.5% of participants subjectively rated the PEP Lab protocol as easiest to complete. Conclusions: Although similar V·O2peak and HRpeak measures were achieved, a lower perceived level of difficulty was observed for the PEP Lab protocol. We speculate that the PEP Lab protocol resulted in higher SBPpeak and lower RERpeak due to the lower initial intensity and smaller stage intensity increments, which may have permitted more gradual cardiorespiratory and metabolic adjustments.
This study aimed to (1) demonstrate the intra- and interrater reliability of quadriceps (QUADS) and hamstring (HAMS) mineral-free lean (MFL) mass measures using DXA scanning, (2) determine the association of total thigh MFL mass measures with MFL mass measures of the hamstrings and quadriceps combined and (3) analyze the association between total thigh MFL mass and total body MFL mass measures. A total of 80 young children (aged 5 to 11 yrs) participated and unique regions of interest were created using custom analysis software with manual tracing of the QUADS, HAMS, and total thigh MFL mass measures. Repeated-measure analysis of variance was used to determine if there were significant differences among the MFL measures while intraclass correlation coefficients (ICC), coefficients of variation (CV), and regression analysis were used to determine the intra- and interrater reliability and the explained variance in the association among MFL mass measures. The right interrater QUADS MFL mass was the only significant group mean difference, and ICCs between (≥0.961) and within (≥0.919) raters were high for all MFL measures with low variation across all MFL measures (≤6.13%). The explained variance was 92.5% and 96.3% for the between-investigator analyses of the right and left total thigh MFL mass measures, respectively. Furthermore, 97.5% of the variance in total body MFL mass was explained by the total thigh MFL mass. DXA MFL mass measures of the QUADS, HAMS and total thigh can be confidently used in young children and may provide an alternative to CT or MRI scanning when assessing changes in MFL cross-sectional area or volume measures due to disease progression, training and rehabilitative strategies.