Introduction: Valid epidemiological data about distal fibular fractures and their treatment strategies are missing. Innovative osteosynthesis techniques were introduced and improved during the past 15 years. The aim of this study was to investigate the epidemiologic development and the implementation of new treatment strategies in a nationwide register in Germany over a period of 15 years. Materials and methods: Data of the German Federal Statistical Office from 2005 until 2019 were screened. Adults with a fracture of the distal fibula were included. Data were separated for gender, age and treatment strategy. Results: During the past 15 years, there was a steady annual incidence of distal fibula fractures of 74 ± 32 per 100,000 people without any significant changes (p = 0.436). 60.1% ± 0.6% of all fractures occurred in females. The annual incidence for male was nearly constant over the different age groups, whereas for female, there was a clear increase in incidence above the age of 40. Whereas 66% of fractures in between 20 and 30 years of age occurred in male, approximately 70% of fractures above the age of 60 occurred in females. The relative quantity of locking plates increased from 2% in 2005 to 34% in 2019. In 2019, only 1.02% of the patients were operated with an intramedullary nail. Conclusions: Operatively treated distal fibular fractures revealed an age dependent increase in incidence in postmenopausal women compared to younger females. Regarding the treatment strategy, there was an increase in application of locking plates. The data implicate a typical fragility fracture related age and gender distribution for distal fibula fractures.
Aims: Biofilm formation is one of the primary reasons for the difficulty in treating implant-related infections (IRIs). Focused high-energy extracorporeal shockwave therapy (fhESWT), which is a treatment modality for fracture nonunions, has been shown to have a direct antibacterial effect on planktonic bacteria. The goal of the present study was to investigate the effect of fhESWT on Staphylococcus aureus biofilms in vitro in the presence and absence of antibiotic agents. Methods: S. aureus biofilms were grown on titanium discs (13 mm × 4 mm) in a bioreactor for 48 hours. Shockwaves were applied with either 250, 500, or 1,000 impulses onto the discs surrounded by either phosphate-buffered saline or antibiotic (rifampin alone or in combination with nafcillin). The number of viable bacteria was determined by quantitative culture after sonication. Representative samples were taken for scanning electron microscopy. Results: The application of fhESWT led to a ten-fold reduction in bacterial counts on the metal discs for all impulse numbers compared to the control (p < 0.001). Increasing the number of impulses did not further reduce bacterial counts in the absence of antibiotics (all p > 0.289). Antibiotics alone reduced the number of bacteria on the discs; however, the combined application of the fhESWT and antibiotic administration further reduced the bacterial count compared to the antibiotic treatment only (p = 0.032). Conclusion: The use of fhESWT significantly reduced the colony-forming unit (CFU) count of a S. aureus biofilm in our model independently, and in combination with antibiotics. Therefore, the supplementary application of fhESWT could be a helpful tool in the treatment of IFIs in certain cases, including infected nonunions. Cite this article: Bone Joint Res 2021;10(1):77–84.
17 April 2025 in Journal of Bone and Joint Surgery
Background: The treatment of ankle fractures involving the posterior malleolus (PM) has changed in favor of open reduction and internal fixation (ORIF), and the need for additional syndesmotic stabilization has decreased; however, there are still doubts regarding the diagnosis and treatment of residual syndesmotic instability. The aim of the present study was to evaluate the effect of fixation of the PM and to assess the need for additional stabilization methods. We hypothesized that ORIF of the PM would not sufficiently stabilize the syndesmosis and that additional syndesmotic reconstruction would restore kinematics. Methods: Eight unpaired, fresh-frozen, cadaveric lower legs were tested in a 6-degrees-of-freedom robotic arm with constant loading (200 N) in the neutral position and at 10° dorsiflexion, 15° plantar flexion, and 30° plantar flexion. The specimens were evaluated in the following order: intact state; osteotomy of the PM; transection of the anterior inferior tibiofibular ligament (AITFL) and interosseous ligament (IOL); ORIF of the PM; additional syndesmotic screw; combination of syndesmotic screw and AITFL augmentation; and AITFL augmentation. Results: A complete simulated rupture of the syndesmosis (PM osteotomy with AITFL and IOL transection) caused translational (6.9 mm posterior and 1.8 mm medial displacement) and rotational instability (5.5° external rotation) of the distal fibula. ORIF of the PM could eliminate this instability in the neutral ankle position, whereas sagittal and rotational instability remained in dorsiflexion and plantar flexion. The remaining instability could be eliminated with an additional procedure, without notable differences between screw and AITFL augmentation. Conclusions: In our model, isolated PM osteotomy and isolated AITFL and IOL rupture (after PM refixation) only partially increased fibular motion in dorsiflexion and plantar flexion, whereas the combination of PM osteotomy and AITFL and IOL rupture resulted in an unstable syndesmosis in all planes. Clinical Relevance: In complex ankle fractures, ORIF of the PM is essential to restore syndesmotic stability; however, residual syndesmotic instability can be detected by a specific posterior shift of the fibula on stress testing. In these cases, anatomical AITFL augmentation is biomechanically equivalent to the use of a syndesmotic screw.
Background/Objectives: Orthoses are commonly used in the treatment of various foot and ankle injuries and deformities. An effective technology in foot orthoses is a vacuum system to improve the fit and function of the orthosis. Recently, a new technology was designed to facilitate the wearing of the foot orthoses while maintaining function without the need for vacuum suction. Methods: A plantar dynamic pressure distribution measurement was carried out in 25 healthy subjects (13 w/12 m, age 23–58 y) using capacitive measuring insoles in two differently designed inlays within the VACOpedes® orthosis (Group A: vacuum inlay vs. Group B: XELGO® inlay) and a regular off-the-shelf shoe (Group C, OTS). The peak plantar pressure, mean plantar pressure and maximum force were analyzed in the entire foot and in individual regions of the medial and lateral forefoot, the midfoot and the hindfoot. Finally, the wearing comfort was compared using a visual analog scale from 1 to 10 (highest comfort). Results: The peak pressure of both inlays was significantly lower than in the OTS shoe (A: 230.6 ± 44.6 kPa, B: 218.0 ± 49.7 kPa, C: 278.6 ± 50.5 kPa; p < 0.001). In a sub-analysis of the different regions, the XELGO® inlay significantly reduced plantar pressure in the medial forefoot compared to the vacuum orthosis (A: 181.7 ± 45.7 kPa, B: 158.6 ± 51.7 kPa, p < 0.002). The wearing comfort was significantly higher with the XELGO® inlay compared to the vacuum inlay (A: 5.68/10, B: 7.24/10; p < 0.001). Conclusions: The VACOpedes® orthosis with a new XELGO® inlay showed at least equivalent relief in all pressure distribution measurements analyzed and greater relief in the forefoot area than the VACOpedes® orthosis with a vacuum inlay, as well as increased wearing comfort.