CMOS–MEMS microresonators have become excellent candidates for developing portable chemical VOC sensing systems thanks to their extremely large mass sensitivity, extraordinary miniaturization capabilities, and on-chip integration with CMOS circuitry to operate as a self-sustained oscillator. This paper presents two 4-anchored MEMS plate resonators, with a resonance frequency of 2.2 MHz and 380 kHz, fabricated together with the required circuitry using a commercial 0.35 μm CMOS technology and then coated with poly-4-vinylheduorocumyl alcohol (P4V) via inkjet deposition. Such P4V constitutes a functionalization layer for specific acetone detection as a key step in the development of an integrated device for non-invasive diabetes diagnosis through exhaled human breath. The coated sensor system has been proven to increase the acetone injection response by 6-times compared to the uncoated platform and shows a cross-sensitivity to butane of 1 : 11. Experimental data show an acetone sensitivity of −0.012 ppm Hz−1 in the best case that, together with a measured frequency Allan deviation of 0.32 ppm, provides an expected limit of detection as low as 20 ppb of acetone. Additionally, this work presents an alternative resonator design with folded flexure anchors that provide a drastic reduction of the sensor temperature sensitivity and mitigate the impact of a fluid flow inherent to the calibration system.
This paper presents the design, fabrication, and electrical characterization of an electrostatically actuated and capacitive sensed 2-MHz plate resonator structure that exhibits a predicted mass sensitivity of ~250 pg·cm−2·Hz−1. The resonator is embedded in a fully on-chip Pierce oscillator scheme, thus obtaining a quasi-digital output sensor with a short-term frequency stability of 1.2 Hz (0.63 ppm) in air conditions, corresponding to an equivalent mass noise floor as low as 300 pg·cm−2. The monolithic CMOS-MEMS sensor device is fabricated using a commercial 0.35-μm 2-poly-4-metal complementary metal-oxide-semiconductor (CMOS) process, thus featuring low cost, batch production, fast turnaround time, and an easy platform for prototyping distributed mass sensors with unprecedented mass resolution for this kind of devices.
CMOS-MEMS resonators have become a promising solution thanks to their miniaturization and on-chip integration capabilities. However, using a CMOS technology to fabricate microelectromechanical system (MEMS) devices limits the electromechanical performance otherwise achieved by specific technologies, requiring a challenging readout circuitry. This paper presents a transimpedance amplifier (TIA) fabricated using a commercial 0.35-µm CMOS technology specifically oriented to drive and sense monolithically integrated CMOS-MEMS resonators up to 50 MHz with a tunable transimpedance gain ranging from 112 dB to 121 dB. The output voltage noise is as low as 225 nV/Hz1/2—input-referred current noise of 192 fA/Hz1/2—at 10 MHz, and the power consumption is kept below 1-mW. In addition, the TIA amplifier exhibits an open-loop gain independent of the parasitic input capacitance—mostly associated with the MEMS layout—representing an advantage in MEMS testing compared to other alternatives such as Pierce oscillator schemes. The work presented includes the characterization of three types of MEMS resonators that have been fabricated and experimentally characterized both in open-loop and self-sustained configurations using the integrated TIA amplifier. The experimental characterization includes an accurate extraction of the electromechanical parameters for the three fabricated structures that enables an accurate MEMS-CMOS circuitry co-design.
We analyzed experimentally the noise characteristics of fully integrated CMOS-MEMS resonators to determine the overall thermomechanical noise and its impact on the limit of detection at the system level. Measurements from four MEMS resonator geometries designed for ultrasensitive detection operating between 2-MHz and 8-MHz monolithically integrated with a low-noise CMOS capacitive readout circuit were analyzed and used to determine the resolution achieved in terms of displacement and capacitance variation. The CMOS-MEMS system provides unprecedented detection resolution of 11 yF·Hz−1/2 equivalent to a minimum detectable displacement (MDD) of 13 fm·Hz−1/2, enabling noise characterization that is experimentally demonstrated by thermomechanical noise detection and compared to theoretical model values.
Volatile organic compounds (VOCs) have gained the biomedical community’s attention given their relevance in exhaled human breath analysis for noninvasive disease diagnosis. Today, only bulky, expensive, and high-skill bench-top equipment is commercially available to reach the outstanding resolution and selectivity required for their detection. However, these solutions fail to meet the society demands of portable and low-cost devices required for point-of-care diagnosis and e-health. In this line, resonant inertial mass sensing has emerged as a promising technique to achieve high-resolution VOCs’ identification, fulfilling the portability requirements. Their excellent distributed mass sensitivity and integration capabilities within standard CMOS microfabrication techniques constitute excellent candidates for building lab-on-chip applications in line with current technological trends. The capability of operating as self-sustained oscillators provides an inherent real-time tracking system with quasi-digital output. Resonator coating using novel sensing films for specific analyte caption is required to boost the mass loading effect and improve sensing selectivity. This article reviews and analyzes the resonator topologies proposed in the literature together with the techniques used for electromechanical transduction, as well as coating materials and procedures. The ultimate goal is to discuss the advantages achieved for CMOS fully integrated solutions, analyzing the state of the art in the field and providing specific design guidelines while foreseeing upcoming trends.
This article presents a fully differential tunable high-gain transimpedance amplifier (TIA) conceived as front-end circuit for monolithic CMOS-MEMS resonators operating in self-sustained oscillation mode. The proposed solution is based on a capacitive feedback network topology using a varactor for gain control. The design is specifically oriented to CMOS-MEMS biosensing applications that require post-CMOS MEMS processing. The adoption of a TIA solution provides robustness against one of such processing steps (i.e., oxygen plasma activation) and a 10 improvement in feedthrough signal elimination compared to a single-ended alternative. The ASIC was fabricated using a 0.35-μm commercial CMOS technology from Austria Microsystems featuring a maximum transimpedance gain of 164 dBΩ with a 10-dB tuning range. It operates at frequencies up to 10 MHz with an input-referred current noise density as low as 13 fA·Hz -1/2 providing an exceptional high-performance sensing. With a 3.3 V supply voltage, it exhibits a 1.6 mW power consumption. The presented TIA was integrated on-chip with various MEMS resonator topologies, either oriented to volatile organic compounds (VOCs) detection or to microfluidics integration for Lab-on-Chip (LoC) systems, corroborating self-sustained oscillation with a 135-ppb measured Allan deviation and 1.1 V output voltage swing.