Jaume Segura

Dr. Jaume Segura


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 March 2012 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
XGXavier Gili
Xavier Gili
SBSalvador Barcelo
Salvador Barcelo
SBSebastia Bota
Sebastia Bota
JSJaume Segura
Jaume Segura
We present a single event transient (SET) propagation model that can be used to quantify the propagation likelihood of a given noise waveform trough CMOS logic gates. This analysis is key to predict if an SET induced within a combinational block is capable of causing an SEU. The model predicts the output noise characteristics given the input noise waveform for each gate, and can be applied to any CMOS technology through a one-time library parameter extraction process. Pulse propagation is described through continuous analytical functions that convert an SET pulse height and width at the gate input to an SET pulse height and width at its output. The noise transfer curves have relatively simple analytical continuous expressions suitable for an easy adoption within CAD tools, thus allowing the investigation of pulse propagation through an entire logic block. Comparison between simulations and model show a very good agreement for a commercial 65 nm technology.

19 November 2002
Verified
Conference Paper
Open access
JSJaume Segura
Jaume Segura
MRMiquel Roca
Miquel Roca
DMD. Mateo
D. Mateo
ARA. Rubio
A. Rubio
I/sub DDQ/ testing is a powerful strategy for detecting defects that do not alter the logic behavior of CMOS ICs. Such a technique is very effective especially in the detection of bridging defects although some opens can be also detected. However, an important set of open and parametric defects escape quiescent power supply current testing because they prevent current elevation. Extending the consumption current testing time, from the static period to the dynamic one (i.e. considering the transient current), defects not covered with I/sub DDQ/ can be detected. Simulations using an on-chip sensor show that this technique can reach a high coverage for defects preventing current and also for those raising the static power consumption.

22 September 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
RPRafel Perelló-Roig
Rafel Perelló-Roig
JVJaume Verd
Jaume Verd
JBJoan Barceló
Joan Barceló
SBSebastia Bota
Sebastia Bota
JSJaume Segura
Jaume Segura
This paper presents the design, fabrication, and electrical characterization of an electrostatically actuated and capacitive sensed 2-MHz plate resonator structure that exhibits a predicted mass sensitivity of ~250 pg·cm−2·Hz−1. The resonator is embedded in a fully on-chip Pierce oscillator scheme, thus obtaining a quasi-digital output sensor with a short-term frequency stability of 1.2 Hz (0.63 ppm) in air conditions, corresponding to an equivalent mass noise floor as low as 300 pg·cm−2. The monolithic CMOS-MEMS sensor device is fabricated using a commercial 0.35-μm 2-poly-4-metal complementary metal-oxide-semiconductor (CMOS) process, thus featuring low cost, batch production, fast turnaround time, and an easy platform for prototyping distributed mass sensors with unprecedented mass resolution for this kind of devices.

15 January 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
RPRafel Perelló-Roig
Rafel Perelló-Roig
JVJaume Verd
Jaume Verd
SBSebastia Bota
Sebastia Bota
JSJaume Segura
Jaume Segura
CMOS-MEMS resonators have become a promising solution thanks to their miniaturization and on-chip integration capabilities. However, using a CMOS technology to fabricate microelectromechanical system (MEMS) devices limits the electromechanical performance otherwise achieved by specific technologies, requiring a challenging readout circuitry. This paper presents a transimpedance amplifier (TIA) fabricated using a commercial 0.35-µm CMOS technology specifically oriented to drive and sense monolithically integrated CMOS-MEMS resonators up to 50 MHz with a tunable transimpedance gain ranging from 112 dB to 121 dB. The output voltage noise is as low as 225 nV/Hz1/2—input-referred current noise of 192 fA/Hz1/2—at 10 MHz, and the power consumption is kept below 1-mW. In addition, the TIA amplifier exhibits an open-loop gain independent of the parasitic input capacitance—mostly associated with the MEMS layout—representing an advantage in MEMS testing compared to other alternatives such as Pierce oscillator schemes. The work presented includes the characterization of three types of MEMS resonators that have been fabricated and experimentally characterized both in open-loop and self-sustained configurations using the integrated TIA amplifier. The experimental characterization includes an accurate extraction of the electromechanical parameters for the three fabricated structures that enables an accurate MEMS-CMOS circuitry co-design.

16 September 2018 in Sensors
Verified
Journal Article
Open access
PDF file
RPRafel Perelló-Roig
Rafel Perelló-Roig
JVJaume Verd
Jaume Verd
SBSebastia Bota
Sebastia Bota
JSJaume Segura
Jaume Segura
We analyzed experimentally the noise characteristics of fully integrated CMOS-MEMS resonators to determine the overall thermomechanical noise and its impact on the limit of detection at the system level. Measurements from four MEMS resonator geometries designed for ultrasensitive detection operating between 2-MHz and 8-MHz monolithically integrated with a low-noise CMOS capacitive readout circuit were analyzed and used to determine the resolution achieved in terms of displacement and capacitance variation. The CMOS-MEMS system provides unprecedented detection resolution of 11 yF·Hz−1/2 equivalent to a minimum detectable displacement (MDD) of 13 fm·Hz−1/2, enabling noise characterization that is experimentally demonstrated by thermomechanical noise detection and compared to theoretical model values.

1 December 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
RPRafel Perelló-Roig
Rafel Perelló-Roig
JVJaume Verd
Jaume Verd
SBSebastia Bota
Sebastia Bota
JSJaume Segura
Jaume Segura
Volatile organic compounds (VOCs) have gained the biomedical community’s attention given their relevance in exhaled human breath analysis for noninvasive disease diagnosis. Today, only bulky, expensive, and high-skill bench-top equipment is commercially available to reach the outstanding resolution and selectivity required for their detection. However, these solutions fail to meet the society demands of portable and low-cost devices required for point-of-care diagnosis and e-health. In this line, resonant inertial mass sensing has emerged as a promising technique to achieve high-resolution VOCs’ identification, fulfilling the portability requirements. Their excellent distributed mass sensitivity and integration capabilities within standard CMOS microfabrication techniques constitute excellent candidates for building lab-on-chip applications in line with current technological trends. The capability of operating as self-sustained oscillators provides an inherent real-time tracking system with quasi-digital output. Resonator coating using novel sensing films for specific analyte caption is required to boost the mass loading effect and improve sensing selectivity. This article reviews and analyzes the resonator topologies proposed in the literature together with the techniques used for electromechanical transduction, as well as coating materials and procedures. The ultimate goal is to discuss the advantages achieved for CMOS fully integrated solutions, analyzing the state of the art in the field and providing specific design guidelines while foreseeing upcoming trends.