Ning Hu

Dr. Ning Hu

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2025 in CAAI Transactions on Intelligence Technology
Verified
Journal Article
Open access
NHNing Hu
Ning Hu
QZQing Zhang
Qing Zhang
Real‐time water‐medium endoscopic images can assist doctors in performing operations such as tissue cleaning and nucleus pulpous removal. During medical operating procedures, it is inevitable that tissue particles, debris and other contaminants will be suspended within the viewing area, resulting in blurred images and the loss of surface details in biological tissues. Currently, few studies have focused on enhancing such endoscopic images. This paper proposes a water‐medium endoscopic image processing method based on dual transmittance in accordance with the imaging characteristics of spinal endoscopy. By establishing an underwater imaging model for spinal endoscopy, we estimate the transmittance of the endoscopic images based on the boundary constraints and local image contrast. The two transmittances are then fused and combined with transmittance maps and ambient light estimations to restore the images before attenuation, ultimately enhancing the details and texture of the images. Experiments comparing classical image enhancement algorithms demonstrate that the proposed algorithm could effectively improve the quality of spinal endoscopic images.

16 January 2026 in Sensors
Verified
Journal Article
Open access
PDF file
NHNing Hu
Ning Hu
SLShuai Li
Shuai Li
JTJindong Tan
Jindong Tan
Due to complex underwater environments characterized by severe scattering, absorption, and color distortion, accurate restoration remains challenging. This paper proposes a hybrid approach combining dual transmission estimation, adaptive ambient light estimation with color correction, and a U-Net Transformer (Uformer) for underwater image enhancement. Our method estimates transmission maps by integrating boundary constraints and local contrast, which effectively address visibility degradation. An adaptive ambient light estimation and color correction strategy are further developed to correct color distortion robustly. Subsequently, a Uformer network enhances the restored image by capturing global and local contextual features effectively. Experiments conducted on publicly available underwater image datasets validate our approach. Performance is quantitatively evaluated using widely adopted non-reference image quality metrics, especially Underwater Image Quality Measure (UIQM) and Underwater Color Image Quality Evaluation (UCIQE). The results demonstrate that our proposed method achieves superior enhancement performance over several state-of-the-art methods.

1 May 2026 in Electronics
Verified
Journal Article
Open access
PDF file
NHNing Hu
Ning Hu
SCSenhao Cao
Senhao Cao
Underwater image enhancement has been widely studied to improve visual quality; however, its impact on downstream geometric tasks such as sparse 3D reconstruction remains insufficiently understood. In particular, visually enhanced images do not necessarily lead to improved feature matching or reconstruction performance. This work addresses the problem of selecting appropriate preprocessing strategies for underwater Structure-from-Motion (SfM) pipelines from a task-oriented perspective. We propose a lightweight machine-learning-based preprocessing selector that predicts reconstruction performance from image statistics and recommends suitable enhancement strategies for each input sequence. To ensure reliable evaluation, we introduce a grouped leave-one-parent-sequence-out protocol that avoids overlap-induced bias common in clip-wise splitting. Experiments are conducted on challenging underwater datasets derived from the Real-world Underwater Image Enhancement (RUIE) benchmark, with the primary comparison variable defined as the number of reconstructed sparse 3D points. Supporting geometric variables, including the number of registered images, mean track length, and mean reprojection error, are recorded for interpretation. Results show that preprocessing choices significantly affect reconstruction outcomes and that the optimal strategy is scene-dependent. The proposed selector consistently improved over raw input on the evaluated grouped subset and remained competitive with a strong fixed preprocessing baseline. The grouped leave-one-parent-sequence-out protocol is intended to reduce overlap-induced bias common in clip-wise splitting and to provide a more conservative estimate of generalization. This work highlights the importance of task-aware preprocessing and reliable evaluation in underwater vision systems, offering practical insights for deploying enhancement strategies in real-world 3D reconstruction pipelines.

1 January 2021 in SSRN Electronic Journal
Verified
Preprint
Open access
PDF file
GZGongzi Zhang
Gongzi Zhang
MLMiao Liu
Miao Liu
SZShuwei Zhang
Shuwei Zhang
XWXiang Wang
Xiang Wang
NHNing Hu
Ning Hu
LZLicheng Zhang
Licheng Zhang
Background: Intertrochanteric fracture is a significant risk factor for elder death and disability. Though current guidelines remain controversial for the treatment strategies by limited evidence, intramedullary fixation has overtaken the use of extramedullary fixation as the preferred technique. We aimed to assess the effect of different treatments on death and secondary fracture, and evaluate their cost-effectiveness. Methods: We conducted a population-based cohort study of all intertrochanteric fracture patients (≧60 years) in Beijing from 2008 to 2016, using population-based health database from the Beijing Municipal Health Commission and Beijing Center for Disease Control and Prevention (CDC) . We used multivariable Cox-regression analysis and semi-competing risk model to calculate the clinical effects and determine whether surgical technique was an independent and significant risk factor for death and secondary fracture. We further used inverse probability of treatment propensity-score weighting and did subgroup analyses by age and comorbidities. A Markov model was constructed to evaluate the incremental cost-effectiveness ratios and determine the most cost-effective treatment. Findings: During a median 5.49 years follow-up, a total of 36488 intertrochanteric fracture patients were included. From 2008 to 2016, the proportion of intramedullary fixation increased from 27.7% to 54.4%, while the extramedullary fixation decreased from 42.5% to 20.7%. After adjusted, extramedullary fixation had significantly lower mortality than intramedullary fixation by 8.8% (hazard ratio [HR] 0.839, 95% CI 0.789-0.891), especially for elder patients with fewer comorbidities. After adjusted, extramedullary fixation had significantly lower secondary fracture incidence than intramedullary fixation by 7.4% (hazard ratio [HR] 0.791, 95% CI 0.715-0.875). Extramedullary fixation was the most cost-effective strategy with an incremental cost-effectiveness ratio of $31,354.20 per QALY compared with conservative treatment. Interpretation: Compared to other operative treatments, the extramedullary fixation was associated with lower mortality and secondary fracture incidence, and was the most cost-effective strategy. Funding: National Natural Science Foundation of China (61771489), Program of Beijing Municipal Science and Technology Commission (Z191100004419008). Declaration of Interest: None to declare. Ethical Approval: This study was approved by the biomedical ethics board of the Chinese PLA General Hospital (Ethical Approval No.: S2019-014-01)

10 February 2026 in Research Square
Verified
Preprint
Open access
NHNing Hu
Ning Hu
MLMaochen Li
Maochen Li
SCSenhao Cao
Senhao Cao
Image guided robotic navigation systems frequently rely on reference-based geometric perception pipelines, where accurate spatial mapping is established through multi-stage estimation processes. In biplanar X-ray–guided navigation, such pipelines are widely adopted due to their real-time capability and geometric interpretability. However, navigation reliability is often constrained by an overlooked system-level failure mechanism in which installation-induced structural perturbations introduced at the perception stage can be progressively amplified along the perception–reconstruction–execution chain and ultimately dominate execution-level error and tail-risk behavior. This paper investigates this mechanism from a system-level perspective and presents a unified error propagation modeling framework that explicitly characterizes how installation-induced structural perturbations propagate and couple with pixel-level observation noise through biplanar imaging, projection matrix estimation, triangulation, and coordinate mapping. By combining first order analytic uncertainty propagation with large-scale Monte Carlo simulations, we analyze dominant sensitivity channels and quantify worst-case error behavior beyond mean accuracy metrics. The results demonstrate that rotational installation error acts as a primary driver of system level error amplification, whereas translational misalignment of comparable magnitude plays a secondary role under typical biplanar geometries. Moreover, installation-induced structural perturbations fundamentally alter the system’s sensitivity to perception noise, leading to pronounced tail-risk amplification that cannot be captured by additive error models. Real biplanar X-ray bench-top experiments further confirm that the predicted error amplification trends persist under realistic imaging and feature extraction uncertainty. Beyond the specific context of biplanar X-ray navigation, the findings reveal a broader structural limitation of reference-based, multi-stage geometric perception pipelines in robotics. By explicitly modeling system-level error propagation and tail-risk behavior, this work formulates a systematic framework for reliability assessment, sensitivity analysis, and risk-aware design in safety-critical robotic navigation systems.

26 April 2026 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
NHNing Hu
Ning Hu
SLShuai Li
Shuai Li
JTJindong Tan
Jindong Tan
Underwater images often suffer from mixed degradations, including motion blur, which reduce structural clarity and adversely affect downstream vision tasks. To address this problem, we propose a physically guided Transformer framework for underwater motion deblurring. The proposed method combines two-stage cepstrum-based blur estimation with a point spread function (PSF)-guided self-attention mechanism. Specifically, blur parameters are first robustly estimated through cepstrum analysis, ellipse fitting, and negative-peak refinement, and the resulting PSF is then embedded into the Transformer attention module to guide feature aggregation. On the real underwater benchmark datasets UIEB Challenge-60 and EUVP330, the proposed method achieves UIQM/UCIQE scores of 4.09/0.56 and 3.40/0.58, respectively, significantly outperforming UFPNet and Phaseformer, thereby demonstrating superior perceptual restoration in terms of sharpness, contrast, and color consistency. On the synthetic test set, the proposed method attains 24.23 dB PSNR and 0.918 SSIM, outperforming both recent deep models and classical non-blind deconvolution methods, which confirms its strong restoration fidelity and structural consistency. In the controlled water-tank experiments, the proposed method consistently achieves the best performance under different camera motion speeds, demonstrating excellent robustness and practical applicability. Overall, the proposed framework provides an effective and physically interpretable solution for underwater motion deblurring.