The phase measurement deflectometry considering the refraction effect is presented to measure the mirror surface in this paper. In the context of the conventional phase measurement deflectometry, the biplanar structure of the system constructed by spatial multiplexing of a screen or a half mirror with two screens is a compromise of traditional display technology, while they suffer from complex calibration process and low accuracy. To improve the system compactness and efficiency, a novel measurement model consisting of a transparent screen and an ordinary screen is used to determine the incident light. To compensate for the measurement errors caused by transparent screen refraction, the refraction of the transparent screen is characterized by two physical parameters, which can be calibrated thanks to the multi-stereo vision technique. Then, the improved mirror calibration method with the refraction model is proposed to determine the posed relationship of the system. After that, the three-dimensional (3D) information of mirror surface is restored by the radial basis function interpolation with the optimized refraction parameters and posed relationships from the gradient data which is transformed from the normal information. Higher measurement efficiency, higher measurement accuracy and more compactness of the proposed measurement method are verified by the experimental results.
In a conventional three-dimensional (3D) measurement technique of a line-scan camera, the projection system based on surface structured light is a compromise of traditional projection technology, which suffers from complex calibration, complex structure and low accuracy. To this end, the coding line structured light based on the coded line laser projection system is proposed to address the 3D measurement of a line-scan camera. The single-line projection and codeable characteristics of coded line laser projection system (constructed by a point laser and a micro-electro-mechanical system (MEMS) scanning galvanometer and modeled as the line projection model) are fully matched with the imaging mode of the line-scan camera. The 3D measurement model based on the height information, lateral information and absolute phase of the coding line structured light is derived. The multi-position flat display calibration method is proposed to calibrate the system parameters. In addition, in order to obtain the accurate absolute phase from the phase shift combined binary code, the periodic error correction method based on expansion-corrosion is proposed to correct the phase error. Contrary to conventional structured light methods based on a line-scan camera, the proposed method has the advantages of high measurement accuracy, high efficiency, more compactness and low cost. The experiments affirm that the coding line structured light is valid and the proposed calibration method is feasible. Experimental results also indicate that the proposed method performs well for both diffuse reflective surfaces and reflective surfaces that are difficult to measure with conventional structured light methods based on a line-scan camera.
23 September 2020 in Measurement Science and Technology
In this paper, a novel approach is proposed to calibrate an underwater fisheye camera with the multi-frequency heterodyne technique based on the light field. First, an underwater fisheye camera imaging model based on the light field is established to demonstrate the multiple refractions of light in underwater propagation and the extraordinary imaging characteristics of the fisheye lens, which shows better conciseness and organization. Then, the calibration method applied in the underwater fisheye camera imaging system is proposed to determine the mapping of the light field and the pose of the underwater fisheye camera. The light field mapping of the fisheye lens is obtained with the assistance of the multi-frequency heterodyne technique. Finally, an underwater fisheye camera is developed and the experimental results are obtained to validate the correctness and feasibility of the proposed method. Our underwater imaging system proves capable of achieving higher accuracy in the context of underwater 3D measurement.
9 September 2020 in Measurement Science and Technology
To solve the problem of large measurement errors caused by vibrations of the surrounding environment, an error reduction method of a binocular measurement system is proposed. A light pen with a V-8 layout is designed to estimate the pose, and coded markers are used to establish a dynamic reference coordinate system to reduce the measurement error mainly caused by vibrations. The experimental results indicate that the light pen is highly accurate in pose estimation, and a root mean square error of the standard blocks and standard balls can be achieved within 0.02 mm when the measurement distance is 1.5 m. By measuring the straightness error of an ABB robot’s manipulator in a comparative experiment, the effective establishment of the dynamic reference coordinate system is preliminarily proven. The experiments are then conducted under vibrating conditions to calculate the standard deviations of the light pen probe center on the X-, Y -, and Z -axes with different quantities (3 and 4) of coded markers, which verify the high accuracy and real-time requirement of the method with a standard deviation below 0.040 mm and a processing speed above 45 frames per second when the measurement distance is 2 m.
14 December 2020 in Measurement Science and Technology
To solve the issue of phase recovery from low-quality fringe images (where the low quality is caused by noise, non-linear intensity and surface reflectivity changes), an iterative phase-correction method is proposed. The high-phase-precision solution is achieved by regenerating the phase-shift-fringe images from the wrapped phase and performing iterative filtering. In general, compared with conventional methods, the proposed iterative phase-correction method has three main advantages: (a) it suppresses the influence of noise without interference from surface reflectivity; (b) it effectively improves the wrapped phase accuracy, thereby improving 3D measurement accuracy, and (c) it effectively recovers the absolute phase (determined by a multi-frequency heterodyne method) information of surfaces with very low or very high reflectivities, without the additional projection of phase-shift-fringe images. The effectiveness of the proposed iterative phase-correction method is verified by simulation and experiment. The proposed method, applied to binocularly structured light, can improve measurement accuracy and greatly improve the effectiveness of measurement of objects with drastic changes in reflectivity. Based on the calibration accuracy (without gamma calibration of the projector) described in this paper, the root-mean-square deviation of the measurement results for binocularly structured light can reach 0.0094 mm.