Xu Zhang

Xu Zhang


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 November 2018 in MATEC Web of Conferences
Verified
Journal Article
Open access
YWYing Wang
Ying Wang
XZXu Zhang
Xu Zhang
With the development of smart city in major cities at home and abroad, especially the management of smart city, how to improve the intelligence level of urban environment monitoring and evaluation has become an important research topic. It is of great value to rapidly and accurately detect garbage from urban images in the application of intelligent urban management. This paper aims to adopt a deep learning strategy for automatic garbage detection. By training a Faster R-CNN open source framework with region proposal network and ResNet network algorithm, we look over garbage detection results on garbage images. In addition, to improve the accuracy of the method, a data fusion and augmentation strategy is proposed. As a result, experiments show that the method has favorable generalization ability and high-precision detection function.

10 December 2018 in Optics Express
Verified
Journal Article
Open access
PDF file
LCLi Chen
Li Chen
YLYoufu Li
Youfu Li
YXYi Xiao
Yi Xiao
XZXu Zhang
Xu Zhang
DTDawei Tu
Dawei Tu
The phase measurement deflectometry considering the refraction effect is presented to measure the mirror surface in this paper. In the context of the conventional phase measurement deflectometry, the biplanar structure of the system constructed by spatial multiplexing of a screen or a half mirror with two screens is a compromise of traditional display technology, while they suffer from complex calibration process and low accuracy. To improve the system compactness and efficiency, a novel measurement model consisting of a transparent screen and an ordinary screen is used to determine the incident light. To compensate for the measurement errors caused by transparent screen refraction, the refraction of the transparent screen is characterized by two physical parameters, which can be calibrated thanks to the multi-stereo vision technique. Then, the improved mirror calibration method with the refraction model is proposed to determine the posed relationship of the system. After that, the three-dimensional (3D) information of mirror surface is restored by the radial basis function interpolation with the optimized refraction parameters and posed relationships from the gradient data which is transformed from the normal information. Higher measurement efficiency, higher measurement accuracy and more compactness of the proposed measurement method are verified by the experimental results.

28 June 2020 in International Journal of Intelligent Robotics and Applications
Verified
Journal Article
Closed access
PDF file
BXBeixin Xia
Beixin Xia
JCJianbin Cao
Jianbin Cao
XZXu Zhang
Xu Zhang
YPYunfang Peng
Yunfang Peng

29 September 2017 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
QZQuan Zhang
Quan Zhang
CLChaodong Li
Chaodong Li
JZJiantao Zhang
Jiantao Zhang
XZXu Zhang
Xu Zhang
The macro–micro combined approach, as an effective way to realize trans-scale nano-precision positioning with multi-dimensions and high velocity, plays a significant role in integrated circuit manufacturing field. A 3-degree-of-freedoms (3-DOFs) macro–micro manipulator is designed and analyzed to compromise the conflictions among the large stroke, high precision and multi-DOFs. The macro manipulator is a 3-Prismatic-Revolute-Revolute (3-PRR) structure parallel manipulator which is driven by three linear ultrasonic motors. The dynamic model and the cross-coupling error based synchronized motion controller of the 3-PRR parallel manipulator are theoretical analyzed and experimental tested. To further improve the positioning accuracy, a 3-DOFs monolithic compliant manipulator actuated by three piezoelectric stack actuators is designed. Then a multilayer BP neural network based inverse kinematic model identifier is developed to perform the positioning control. Finally, by forming the macro–micro structure, the dual stage manipulator successfully achieved the positioning task from the point (2 mm, 2 mm, 0 rad) back to the original point (0 mm, 0 mm, 0 rad) with the translation errors in X and Y directions less than ±50 nm and the rotation error around Z axis less than ±1 μ rad, respectively.

9 October 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YSYijun Shen
Yijun Shen
YZYaqi Zhang
Yaqi Zhang
LYLifang Yan
Lifang Yan
NHNuodi Huang
Nuodi Huang
XZXu Zhang
Xu Zhang
Zhu LiMinZhu LiMin
Zhu LiMin
The raising demand for high-efficiency inspection in industrial manufacturing has significantly increased the required measurement speed, resulting in extra dynamic errors during measurement. Although the dynamic error modeling and compensation for the Coordinate Measuring Machine (CMM) has been widely investigated, the influence of the dynamic error on the scanning probe system has attracted few attention. In this paper, the dynamic performance of the scanning probe is analyzed and the dynamic error is modeled as the constant time delay in the response of a second-order system subjected to the ramp excitation. The delay-inclusive probe model is proposed to compensate the dynamic error in the probe signal and the corresponding calibration method is given to identify the constant time delay, which only requires to probe 25 points on a sphere. Three sets of probing and scanning experiments are conducted to compare the accuracy of the proposed method against the existing methods in high-speed measurement. Although the probing accuracy with the existing calibration methods is reduced to several tens of micrometers in high-speed probing, the proposed method maintains micro-level accuracy, which is basically identical to the accuracy in low-speed. Moreover, the calibration time for the proposed method is only 17.4% of the Renishaw commercial calibration method.

14 March 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YSYijun Shen
Yijun Shen
YZYang Zhang
Yang Zhang
LYLifang Yan
Lifang Yan
XZXu Zhang
Xu Zhang
Zhu LiMinZhu LiMin
Zhu LiMin
Scanning probes would achieve superior accuracy and efficiency compared to touch-trigger probes when performing measurement on a Coordinate Measuring Machine(CMM). However, existing research has found that the calibration time for scanning probes is much longer than that for touch-trigger probes, owing to the complex calibration setups and procedures of current methods. For industrial inspection applications requiring multiple probe angles, calibration time significantly impacts on overall efficiency. In this paper, we design a scanning probe based on three-layer parallel leaf-springs and three orthogonally arranged displacement sensors. A semi-linear mathematical model with a minimal number of parameters is established for this probe. By fully utilizing all data collected during the probing, the proposed method simplifies the calibration procedure, requiring only 25 points to be probed on a sphere artifact. Four sets of precision tests are conducted to compare the accuracy of the proposed calibration method with Renishaw’s commercial calibration method on the designed probe and Renishaw’s SP25 probe is used as the benchmark. The results demonstrate that our calibration method can achieve similar or even higher accuracy compared to Renishaw’s calibration method. Moreover, our calibration time is only 36.6% of that of Renishaw’s method, which validates our proposed method. This advancement holds promising implications for enhancing productivity in industrial CMM applications.