3D-printed blocks with drop coating could work as diffraction gratings while the layer stepping serves as the grooves of the gratings. This paper reports 3D-printed diffraction gratings coated with different resins. A collimated laser with a wavelength of 520 nm passed through the gratings and generated diffraction patterns. Optical path differences and surface profiles of the samples were measured to analyze the mechanism of the diffraction phenomenon. The as-printed samples had a grating height of about 8 µm induced by layer stepping, which could not generate clear diffraction patterns because of too large optical path difference. After being coated with different resins on the surfaces, the printed samples generated diffraction patterns. We experimentally showed that the magnitude of optical path differences became close to the wavelength of the laser and that the diffraction phenomenon was mainly caused by the difference in the refractive indices between the as-printed part and the drop-coated part. This novel method enables low-cost 3D printers to fabricate diffractive optical elements for visible light.
The spectral quality of magnetic resonance spectroscopic imaging (MRSI) can be affected by strong magnetic field inhomogeneities, posing a challenge for 3D-MRSI’s widespread clinical use with standard scanner-equipped 2nd-order shim coils. To overcome this, we designed an empirical unified shim–RF head coil (32-ch RF receive and 51-ch shim) for 3D-MRSI improvement. We compared its shimming performance and 3D-MRSI brain coverages against the standard scanner shim (2nd-order spherical harmonic (SH) shim coils) and integrated parallel reception, excitation, and shimming (iPRES) 32-ch AC/DC head coil. We also simulated a theoretical 3rd-, 4th-, and 5th-order SH shim as a benchmark to assess the UNIfied shim–RF coil (UNIC) improvements. In this preliminary study, the whole-brain coverage was simulated by using B0 field maps of twenty-four healthy human subjects (n = 24). Our results demonstrated that UNIC substantially improves brain field homogeneity, reducing whole-brain frequency standard deviations by 27% compared to the standard 2nd-order scanner shim and 17% compared to the iPRES shim. Moreover, UNIC enhances whole-brain coverage of 3D-MRSI by up to 34% compared to the standard 2nd-order scanner shim and up to 13% compared to the iPRES shim. UNIC markedly increases coverage in the prefrontal cortex by 147% and 47% and in the medial temporal lobe and temporal pole by 29% and 13%, respectively, at voxel resolutions of 1.4 cc and 0.09 cc for 3D-MRSI. Furthermore, UNIC effectively reduces variations in shim quality and brain coverage among different subjects compared to scanner shim and iPRES shim. Anticipated advancements in higher-order shimming (beyond 6th order) are expected via optimized designs using dimensionality reduction methods.