Turbines are rotating machines that generate power by the expansion of a fluid; due to their characteristics, these turbomachines are widely applied in aerospace propulsion systems. Due to the clearance between the rotor blade tip and casing, there is a leakage flow from the blade pressure to the suction sides, which generates energy loss. There are different strategies that can be applied to avoid part of this loss; one of them is the application of so-called desensitization techniques. The application of these techniques on gas turbines has been widely evaluated; however, there is a lack of analyses of hydraulic turbines. This study is a continuation of earlier analyses conducted during the first stage of the hydraulic axial turbine used in the low-pressure oxidizer turbopump (LPOTP) of the space shuttle main engine (SSME). The previous work analyzed the application of squealer geometries at the rotor tip. In the present paper, winglet geometry techniques are investigated based on three-dimensional flowfield calculations. The commercial CFX v.19.2 and ICEM v.19.2 software were used, respectively, on the numerical simulations and computational mesh generation. Experimental results published by the National Aeronautics and Space Administration (NASA) and data from previous works were used on the computational model validation. The parametric analysis was conducted by varying the thickness and width of the winglet. The results obtained show that by increasing the winglet thickness, the stage efficiency is also increased. However, the geometric dimension of its width has minimal impact on this result. An average efficiency increase of 2.0% was observed across the entire turbine operational range. In the case of the squealer, for the design point, the maximum efficiency improvement was 1.62%, compared to the current improvement of 2.23% using the winglet desensitization technique. It was found that the proposed geometries application also changes the cavitation occurrence along the stage, which is a relevant result, since it can impact the turbine life cycle.
Turbines are rotating machines that generate power by the expansion of a fluid; due to their characteristic these turbomachines are widely applied in the aerospace propulsion systems. Since due to the clearance between rotor blade tip and casing, there is a leakage flow from blade pressure to suction sides, which generates an energy loss. There are different strategies that can be applied to avoid part of this loss, one of them is by the application of the called desensitization techniques. The application of these techniques on gas turbines have been widely evaluated, however, there is a lack of these analyzes for hydraulic turbines. This work is a sequence of previous analyzes developed for the first stage of the hydraulic axial turbine used on the Space Shuttle Main Engine (SSME) Low Pressure Oxidizer Turbopump (LPOTP). The last work analyzed the application of squealer geometries at rotor tip. In the present paper, the winglet geometry techniques were investigated based on three-dimensional flowfield calculation. The commercial CFX v.19.2 and ICEM v.19.2 software were used, respectively, on the numerical simulations and computational meshes generation. Experimental results published by the National Aeronautics and Space Administration (NASA), and data from previous works, were used on the computational model validation. The parametric analysis was done by the variation in the winglet thickness and width. The results obtained shown that increasing the winglet thickness, the stage efficiency is also increased. However, its width geometrical dimension almost does not impact this result. It was verified an efficiency increase of 2.0%, over the entire turbine operational range. It was found that the proposed geometries application also changes the cavitation occurrence along the stage, which is a relevant result, since it can impact the turbine life cycle.
10 February 2023 in SAE International Journal of Advances and Current Practices in Mobility
Compression ignition engines are widely used in the cargo and passenger transport sectors, this is due to their high energy efficiency and can operate with renewable fuels. The search for increased efficiency in internal combustion engines and reduced emissions are increasingly stringent, so to meet regulatory emission standards, new technologies are being studied and developed to reduce emissions generated by engines, in the case of diesel engines compression ignition, studies of techniques to reduce NOx and soot have been carried out. One of the techniques studied is the application of the DFI - Ducted Fuel Injection concept, which makes the fuel spray pass through a small cylindrical duct installed upstream of the injection orifice of the injector nozzle, thus improving the air/fuel, making it more homogeneous and allowing a more complete combustion. This work addresses a study of this application of DFI with different compression ratios. To carry out the tests, a thermodynamic single-cylinder engine was used where its compression ratio is 16.0:1 in its normal condition, when the ducts are installed in the combustion chamber the engine starts to operate with a compression ratio of 16.5:1, thus, this study is necessary so that it is possible to visualize the behavior of the engine when the compression ratio changes, aiming at the thermodynamic behavior and emissions. CO, HC and NOx emissions were measured with FTIR spectroscopy equipment, and soot was measured by Laser Induced Incandescence - LII. The difference in compression ratio between DFI and free spray causes soot levels to increase considerably with increasing load in free spray mode, while for DFI the indices are almost unchanged.
27 November 2020 in Anais Congresso Brasileiro de Energia Solar - CBENS
Este trabalho apresenta uma análise termodinâmica de um tubo evacuado utilizado em plantas de energia solar com tecnologia de coletores de calha parabólica aplicada para geração de energia térmica e/ou elétrica. Esta análise apresenta a relação entre os diversos fatores do coletor, localização, incidência solar, fluido de transferência de calor e condições específicas da planta. Foi utilizando o EES (Engineerig Equation Solver) para validação do modelo matemático e verificação da viabilidade técnica de implantação de uma Planta de Concentração Solar por Calha Parabólica em Cachoeira Paulista/SP. Comparou-se os resultados para dois tipos de coletores, onde o LS-3 apresentou maiores eficiências que o LS-2. E constatou-se, como o esperado que, quanto maior for a Insolação Normal Direta (DNI), a temperatura ambiente e a vazão do fluido, além de menor a velocidade do vento, maior será o calor absorvido pelo fluido, podendo chegar até a 1010 W/m e eficiência do sistema de 73,5% para localização em estudo.
A proposta deste trabalho é prever os coeficientes de Wiebe para um motor de ignição por centelha de quatro cursos 1.6l com duplo comando de válvulas variá...