Ceramic materials have many striking prospects as temperature sensors. Still, some inevitable shortcomings comprising toxicity, low biocompatibility, extensive response as well as recovery times, poor sensitivity, and hysteresis obstruct them from various progressive uses. Therefore, in this current exploration, a capacitive temperature sensor has been designed and developed using a lead-free ferroelectric ceramic Bi(Fe 2/3 Ta 1/3 )O 3 (BFT) by solid-state sintering technique. Compared with the conventional capacitive temperature sensor, the proposed BFT-based temperature sensor has a relatively high sensitivity of 280 fF/°C, a fast response time (4.27 s), and a recovery time (7.39 s). The developed sensor provides a reversible response with relatively low hysteresis and excellent repeatability over multiple cycles. The sensor’s response has been recorded for thirty days to confirm long-term stability. The excellent sensing properties of non-toxic BFT sensor make it very promising electronic component for the development of high-performance capacitive temperature sensors for advanced electronic applications.
The wireless drive of an automated implantable electronic sensor has been explored for health monitoring applications. The proposed system comprises of an automated biomedical sensing system which is energized through resonant inductive coupling. The implantable sensor unit is able to monitor the body temperature parameter and sends back the corresponding telemetry data wirelessly to the data recoding unit. It has been observed that the wireless power delivery system is capable of energizing the automated biomedical implantable electronic sensor placed over a distance of 3 cm from the power transmitter with an energy transfer efficiency of 26% at the operating resonant frequency of 562 kHz. This proposed method ensures real-time monitoring of different human body temperatures around the clock. The monitored temperature data have been compared with a calibrated temperature measurement system to ascertain the accuracy of the proposed system. The investigated technique can also be useful for monitoring other body parameters such as blood pressure, bladder pressure, and physiological signals of the patient in vivo using various implantable sensors.
1 January 2018 in Progress In Electromagnetics Research M
In order to energize the biomedical implantable electronic devices wirelessly for in vivo health monitoring of patients in an isolated, outdoor and inaccessible environment, an alternate driving energy source is highly desirable. In pertinent to this, a photovoltaic driven wireless energizing system has been explored. The system is designed to convert solar energy to a high frequency energy source so as to facilitate energy transfer through resonant inductive link to the automated bio-medical sensing system allied with the receiver unit. The received power is observed to be 286 mW for the coil separation gap of 5 cm and load value of 40 Ω at the resonant frequency of 772.3 kHz. The automated biomedical smart sensor is competent to acquire the body parameter and transmit the consequent telemetry data from the body to the data recording segment. The real-time body temperature parameter of different living beings has been experimented, and to ensure the accuracy of the developed system, the observed parameter has been matched with a calibrated system. The proposed scheme can be suitable for monitoring wirelessly other in vivo health parameters such as blood pressure, bladder pressure, and physiological signals of the patients.