Antonela Geber

Dr. Antonela Geber

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2025 in Life
Verified
Journal Article
Open access
PDF file
ASAnita Pusic Sesar
Anita Pusic Sesar
AČAnja Čehajić
Anja Čehajić
AGAntonela Geber
Antonela Geber
MGMia Zorić Geber
Mia Zorić Geber
ICIvan Cavar
Ivan Cavar
ASAntonio Sesar
Antonio Sesar
Background: Obstructive sleep apnea (OSA) is increasingly recognized as a potential risk factor for glaucoma due to its association with intermittent hypoxia and vascular dysregulation. The aim of this study was to investigate early glaucomatous changes in the eyes of patients with OSA. Methods: This case–control study included 25 patients with OSA and 25 age- and sex-matched healthy controls. According to the STOP-Bang Questionnaire, patients with an intermediate or severe risk of OSA underwent polysomnography. Based on the apnea-hypopnea index, only patients with severe OSA were included in the study group. All participants underwent a full ophthalmological examination, with measurements of the retinal nerve fiber layer (RNFL) and ganglion cell layer (GCL) thickness performed using optical coherence tomography (OCT). Results: Statistical comparisons revealed that intraocular pressure (IOP) was slightly elevated, while central corneal thickness (CCT) was slightly reduced in patients with OSA compared to healthy controls. OCT measurements showed an overall reduction in both RNFL and GCL thicknesses in the OSA group. Among these findings, only the differences in average and minimum GCL thickness in the left eye reached statistical significance. Conclusions: The results of our study indicate significant thinning of the GCL in patients with OSA, suggesting possible early glaucomatous changes and a potential link between OSA and glaucoma. Given the increasing prevalence of OSA, further large-scale, long-term studies are needed to better understand this relationship and its clinical implications.

4 April 2025 in Reports
Verified
Journal Article
Open access
PDF file
TKTomislav Kuzman
Tomislav Kuzman
Suzana MatićSuzana Matić
Suzana Matić
IGIvan Gabric
Ivan Gabric
AGAntonela Geber
Antonela Geber
AMAna Meter
Ana Meter
Background and Clinical Significance: Acanthamoeba keratitis (AK) is a rare but serious corneal infection that can lead to severe visual impairment or blindness if not promptly treated. The condition is primarily associated with contact lens use but can also occur due to ocular trauma or environmental contamination. The most frequently used treatment options include biguanides and diamidines, though dosing protocols remain empirical and vary widely among clinicians. Recent research has explored a new standardized protocol with 0.08% polihexanide (polyhexamethylene biguanide, PHMB) as a monotherapy for AK, offering improved efficacy and better corneal penetration. Case Presentation: This case report describes a 35-year-old female contact lens wearer who presented with redness, pain, photophobia, and vision loss in her right eye. Upon referral, a slit-lamp examination revealed stromal infiltrates and perineural involvement, with in vivo confocal microscopy (IVCM) confirming Acanthamoeba cysts. The patient was treated with a new standardized intensive regimen of polihexanide 0.08% monotherapy, leading to rapid clinical improvement. Corneal infiltrates were significantly reduced, and the best-corrected visual acuity (BCVA) improved from 0.4 logMAR to 0.15 logMAR. Resolution with only discrete stromal haze was achieved over the following months, without recurrence. Conclusions: This case highlights the potential of polihexanide 0.08% monotherapy as an effective treatment for AK in a new standardized treatment protocol.

20 July 2025 in Reports
Verified
Journal Article
Open access
PDF file
SPSania Vidas Pauk
Sania Vidas Pauk
AGAntonela Geber
Antonela Geber
IBIva Bešlić
Iva Bešlić
ILInes Lakoš-Jukić
Ines Lakoš-Jukić
TKTomislav Kuzman
Tomislav Kuzman
Background and Clinical Significance: Ocular cicatricial pemphigoid (OCP) is a rare autoimmune disease affecting the conjunctiva and oral mucosa. Chronic inflammation causes conjunctival scarring, leading to symblepharon, trichiasis, corneal damage, and possible blindness. Diagnosis is clinical, supported by biopsy and immunofluorescence. Treatment includes systemic corticosteroids, immunosuppressants, and biologics in refractory cases. Case Presentation: A 64-year-old male presented with ocular irritation, trichiasis, and counting fingers (CF) visual acuity in the left eye. Slit-lamp examination revealed conjunctival inflammation, corneal epithelial defect, and symblepharon in the left eye. Biopsy confirmed ocular cicatricial pemphigoid (OCP). He was treated with topical steroids, cyclosporine, subconjunctival injections, and systemic corticosteroids, followed by surgery, which improved BCVA to 0.10 logMAR. Two years later, disease progression resulted in severe inflammation and visual decline in both eyes. Systemic azathioprine and corticosteroids achieved partial control. Due to insufficient response, rituximab therapy was initiated, leading to significant reduction in inflammation and stabilization of disease. Right eye BCVA improved to 0.16 logMAR; the left remained at CF. The patient continues to receive rituximab during exacerbations and is under regular follow-up. Conclusions: Early diagnosis and timely systemic treatment are essential in preventing vision loss in OCP. In refractory cases, biologic agents like rituximab may offer effective disease control.

31 May 2025 in Medicina
Verified
Journal Article
Open access
PDF file
AGAntonela Geber
Antonela Geber
SMSanja Masnec
Sanja Masnec
MKMiro Kalauz
Miro Kalauz
IBIva Bešlić
Iva Bešlić
IŠIvan Škegro
Ivan Škegro
TKTomislav Kuzman
Tomislav Kuzman
Background and Objectives: Descemet stripping automated endothelial keratoplasty (DSAEK) is a widely used surgical technique for treating corneal endothelial dysfunctions such as Fuchs endothelial corneal dystrophy (FECD) and pseudophakic bullous keratopathy (PBK). This study aimed to investigate the association between postoperative visual acuity and various corneal morphological and optical parameters, including corneal densitometry (CD) and higher-order aberrations (HOAs), measured using the Pentacam (OCULUS Optikgeräte GmbH, Wetzlar, Germany), as well as graft thickness, which was assessed by anterior segment optic coherence tomography (AS-OCT), (Optovue Inc., Fremont, CA, USA), and corneal thickness, assessed by both AS-OCT and Pentacam. Materials and Methods: This prospective, observational cohort study included 17 eyes from 13 patients who underwent DSAEK. Data on preoperative visual acuity were collected, while postoperative parameters were assessed during follow-up visits. Corneal measurements included the total corneal and corneal graft thickness, corneal densitometry in 20 defined subregions, and corneal higher-order aberrations. Associations between these parameters and postoperative visual acuity were evaluated using nonparametric statistical tests. Results: The postoperative visual acuity improved significantly (p < 0.001). Strong correlations were found between poorer visual acuity and higher CD values. The strongest correlations with visual acuity were found for CD 2–6 mm total (Rho = 0.795; p < 0.001), CD central 2–6 mm (Rho = 0.791; p < 0.001), and CD central 0–2 mm (Rho = 0.730; p < 0.001). Significant associations were also observed with anterior and posterior HOAs (Rho = 0.624, p = 0.01; and Rho = 0.556, p = 0.02, respectively). No correlation was found between visual outcomes and graft thickness measured by AS-OCT (Rho = 0.051; p = 0.85), nor with total corneal thickness measured by AS-OCT (Rho = −0.227; p = 0.38) or Pentacam (Rho = −0.369; p = 0.14). Conclusions: This study demonstrates that CD and HOAs are more strongly associated with postoperative visual acuity after DSAEK than traditionally monitored parameters such as graft or corneal thickness. The results highlight the value of detailed corneal imaging and support the use of advanced optical diagnostics in postoperative evaluation.


22 June 2026 in Medicina
Verified
Journal Article
Open access
PDF file
IBIva Bešlić
Iva Bešlić
SPSania Vidas Pauk
Sania Vidas Pauk
Martina TomićMartina Tomić
Martina Tomić
MKMiro Kalauz
Miro Kalauz
TKTomislav Kuzman
Tomislav Kuzman
SMSanja Masnec
Sanja Masnec
Background and Objectives: Corneal collagen cross-linking (CXL) halts keratoconus progression, yet potential differences between conventional and accelerated protocols at one year remain uncertain. We analyzed the completed 12-month follow-up of a previously reported 6-month cohort to compare conventional (3 mW/cm2 × 30 min; CXL 30) versus accelerated (9 mW/cm2 × 10 min; CXL 10) CXL, interpreting outcomes within the ABCD framework alongside Kmax and curvature radii. Materials and Methods: In this single-center retrospective longitudinal analysis of prospectively collected routine clinical data, 22 eyes were included, with assessments performed at baseline and at 1, 3, 6, and 12 months of follow-up. Evaluated outcomes comprised ABCD stages (A–D), anterior and posterior radius of curvature (ARC and PRC), Kmax, pachymetric and elevation indices, as well as UDVA and BCVA. Within-group change used Friedman with Wilcoxon post hoc; between-group differences used Mann–Whitney (α = 0.05). Results: Both protocols resulted in significant visual improvement and Kmax reduction at 12 months (overall time effect: CXL 30 p < 0.001; CXL 10 p = 0.026). Median Kmax decreased 56.5 → 52.3 D (CXL 30) and 59.3 → 58.3 D (CXL 10). UDVA improved 0.2 → 0.6 (CXL 30) and 0.2 → 0.3 (CXL 10); BCVA 0.4 → 0.8 (CXL 30) and 0.2 → 0.5 (CXL 10). Tomographic analysis showed predominantly anterior changes, with a significant decrease in A stage in the CXL 30 group and an increase in ARC in both groups, more pronounced in CXL 30. In the late 6 → 12-month window, posterior metrics (PRC and posterior elevation) were largely stable; raw PRC change did not reach significance. Conclusions: Conventional and accelerated CXL both stabilized keratoconus at one year with meaningful functional gains. Beyond 6 months, remodeling was predominantly anterior; within-group findings suggested a more pronounced anterior tomographic response in the CXL 30 group. The 12-month visit may be useful for reassessing stability after CXL, although this study was not designed to determine optimal retreatment timing or optical rehabilitation strategy. Longer-term studies with standardized biomechanical and densitometric endpoints are warranted to assess durability and refine protocol selection.