The electric power industry sector has become increasingly aware of how counterproductive voltage sag affects distribution network systems (DNS). The voltage sag backfires disastrously at the demand load side and affects equipment in DNS. To settle the voltage sag issue, this paper achieved its primary purpose to mitigate the voltage sag based on integrating a hydrogen fuel cell (HFC) with the DNS using a distribution static synchronous compensator (D-STATCOM) system. Besides, this paper discusses the challenges and opportunities of D-STATCOM in DNS. In this paper, using HFC is well-designed, modeled, and simulated to mitigate the voltage sag in DNS with a positive impact on the environment and an immediate response to the issue of the injection of voltage. Furthermore, this modeling and controller are particularly suitable in terms of cost-effectiveness as well as reliability based on the adaptive network fuzzy inference system (ANFIS), fuzzy logic system (FLC), and proportional–integral (P-I). The effectiveness of the MATLAB simulation is confirmed by implementing the system and carrying out a DNS connection, obtaining efficiencies over 94.5% at three-phase fault for values of injection voltage in HFC D-STATCOM using a P-I controller. Moreover, the HFC D-STATCOM using FLC proved capable of supporting the network by 97.00%. The HFC D-STATCOM based ANFIS proved capable of supporting the network by 98.00% in the DNS.
Considering the recent drop (up to 86%) in photovoltaic (PV) module prices from 2010 to 2017, many countries have shown interest in investing in PV plants to meet their energy demand. In this study, a detailed design methodology is presented to achieve high benefits with low installation, maintenance and operation costs of PV plants. This procedure includes in detail the semi-hourly average time meteorological data from the location to maximise the accuracy and detailed characteristics of different PV modules and inverters. The minimum levelised cost of energy (LCOE) and maximum annual energy are the objective functions in this proposed procedure, whereas the design variables are the number of series and parallel PV modules, the number of PV module lines per row, tilt angle and orientation, inter-row space, PV module type, and inverter structure. The design problem was solved using a recent hybrid algorithm, namely, the grey wolf optimiser-sine cosine algorithm. The high performance for LCOE-based design optimisation in economic terms with lower installation, maintenance and operation costs than that resulting from the use of maximum annual energy objective function by 12%. Moreover, sensitivity analysis showed that the PV plant performance can be improved by decreasing the PV module annual reduction coefficient.
The development of fault detection methods in wind turbine (WT), especially for single fault detection, is continuously increasing. However, the rapid growth of fault detection in WT leads to another challenge where multiple faults can occur. The single fault detection method in WT is no longer reliable, especially when multiple faults occur simultaneously. Therefore, multiple faults detection in doubly-fed induction generators (DFIG) WT was proposed using an artificial neural networks (ANN) model. These multiple faults include internal and external stator faults happening simultaneously. Internal stator faults cover inter-turn short circuit faults and open circuit faults, while external stator faults cover loss of excitation and external short circuit faults. The performance of the developed multiple faults detection model was measured using accuracy and the root mean square error (RMSE) value. The results show that the developed model performs well with high accuracy and a low RMSE value. Thus, the developed model can accurately detect the coexistence of multiple faults in DFIG WT.
1 December 2023 in International Journal of Electrical and Computer Engineering (IJECE)
Transformers are generally easy to access and can contribute significantly to entire power system. When a transformer is turned on for the first time, it produces a magnetising inrush current which acts as a starting current. Energisation of transformer has a substantial impact on inrush current and transformer that are connected in parallel. Sympathetic inrush current is a phenomenon that appears when a transformer is switched-on in network whereas the other transformers that was earlier energised. Besides, when sympathetic inrush phenomena occur, the peak and period fluctuate significantly. In this paper, the transformers will be energised in three different ways and each condition will be explored in depth. The operation time of the transformer’s energisation whether it is energised simultaneously or at different times are tested and analysed in terms of their characteristics. It is performed using power system computer aided design (PSCAD) software, starting with a develop model of the energisation and then generate the outcomes. The results of the simulation demonstrate that energising the transformer in different ways can give different effect on the sympathetic inrush current, as well as the variables that affect it and methods for reducing it.