Ayesha Ayesha

Ms. Ayesha Ayesha

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

6 May 2025 in World Neurosurgery
Verified
Journal Article
Open access
ESEshita Sharma
Eshita Sharma
KLKaike Eduardo da Silva Lobo
Kaike Eduardo da Silva Lobo
AAAyesha Ayesha
Ayesha Ayesha
PŁPaweł Łajczak
Paweł Łajczak
BPBeatriz Westphalen Pomianoski
Beatriz Westphalen Pomianoski
YSYan Gabriel Morais David Silva
Yan Gabriel Morais David Silva
This meta-analysis compares clinical outcomes of minimally invasive decompression (MID) versus open laminectomy surgery (OLS) for multilevel lumbar spinal stenosis. A systematic search was conducted in PubMed, Embase, and the Cochrane Central databases to identify studies comparing MID to OLS in patients with multilevel lumbar spinal stenosis. Primary outcomes were length of hospital stay (LHS), operative time (OT), complication rate (CR), intraoperative blood loss (IBL), reoperation due to recurrence (RDR), and low back pain 1 year after surgery (LBP). Of 3695 articles screened, 4 studies and 618 patients were included, of whom 291 (47%) were treated with MID and 327 (53%) were treated with OLS. There were no significant differences between the groups in OT (Mean Difference (MD)) = 7.68; 95% CI [-20.53, 35.88]; p = 0.59, I2 = 96%), CR (Odds Ratio (OR)) = 0.72; 95% CI [0.04, 14.73]; p = 0.83; I2 = 80%), RDR, LBP and LHS. However, IBL was reduced in MID compared to OLS (MD = -55.20; 95% CI [-105.73, -4.67]; p = 0.03; I2 = 95%), decreasing the need for transfusions and complications. Only the RDR presented a low heterogeneity, while the rest of the outcomes conferred a high heterogeneity. Our study showed important statistical differences between the groups analyzed, likely attributable to inconsistencies in standardized approaches and decompression techniques across studies. Notably, MID demonstrated an advantage over OLS regarding intraoperative blood management.

23 May 2025 in World Neurosurgery
Verified
Journal Article
Open access
PŁPaweł Łajczak
Paweł Łajczak
OSOguz Kagan Sahin
Oguz Kagan Sahin
ESEshita Sharma
Eshita Sharma
AAAyesha Ayesha
Ayesha Ayesha
AŁAnna Łajczak
Anna Łajczak
Robotic-assisted minimally invasive surgery (RA-MIS) is becoming increasingly applied to spinal surgery, offering an alternative to conventional minimally invasive spinal surgery (C-MIS). Recently, RA-MIS has been proposed for pedicle screw instrumentation in thoracolumbar fractures. This review aims to evaluate screw accuracy, RA-MIS and C-MIS among the thoracolumbar fracture population. This study followed PRISMA and Cochrane guidelines. Five medical databases were searched. Finally, 10 studies were included in the meta-analysis, with a total of 562 patients. Outcomes on operation time, blood loss, pedicle screw accuracy, complications, and cost-effectiveness were evaluated. RA-MIS showed superiority in terms of accurate (GR A) screw placement (OR: 3.58, 95% CI: 2.30-5.58, p<.001) and satisfactory (GR A+B) screw placement (OR: 3.86, 95% CI: 2.14-6.96, p<.001) compared to C-MIS. RA-MIS led to a significantly lower incidence of severely misplaced (GR D+E) screws (OR: 0.26, 95% CI: 0.13-0.51, p<.001) and lower blood loss (MD: -12.03, 95% CI: -20.85 to -3.21, p<.01). However, we found no statistically significant differences in operation time (MD: -4.92, 95% CI: -12.06 to 2.22, p=.18) or complications (screw loosening, nerve injury, or infection). Costs of RA-MIS were significantly higher (MD: ¥8657.61, 95% CI: 6651.39 to 10663.83, p<.01). Robotic-assisted minimally invasive spinal surgery is superior in terms of higher pedicle screw accuracy and reduced perioperative blood loss, at the cost of significantly higher costs of surgery. Furthermore, we observed no clear advantages regarding complication rate and total operation time. Future trials should provide a less biased methodology to confirm the findings.

9 September 2025 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
PŁPaweł Łajczak
Paweł Łajczak
OSOguz Kagan Sahin
Oguz Kagan Sahin
JMJakub Matyja
Jakub Matyja
LSLuis Rene Puglla Sanchez
Luis Rene Puglla Sanchez
ISIqbal Farhan Sayudo
Iqbal Farhan Sayudo
MSMichele Schincariol
Michele Schincariol
Myocarditis is an inflammation of heart tissue. Cardiovascular magnetic resonance imaging (CMR) has emerged as an important non-invasive imaging tool for diagnosing myocarditis, however, interpretation remains a challenge for novice physicians. Advancements in machine learning (ML) models have further improved diagnostic accuracy, demonstrating good performance. Our study aims to assess the diagnostic accuracy of ML in identifying myocarditis using CMR. A systematic search was performed using PubMed, Embase, Web of Science, Cochrane, and Scopus to identify studies reporting the diagnostic accuracy of ML in the detection of myocarditis using CMR. The included studies evaluated both image-based and report-based assessments using various ML models. Diagnostic accuracy was estimated using a Random-Effects model (R software). We found a total of 141 ML model results from a total of 12 studies, which were included in the systematic review. The best models achieved 0.93 (95% Confidence Interval (CI) 0.88–0.96) sensitivity and 0.95 (95% CI 0.89–0.97) specificity. Pooled area under the curve was 0.97 (95% CI 0.93–0.98). Comparisons with human physicians showed comparable results for diagnostic accuracy of myocarditis. Quality assessment concerns and heterogeneity were present. CMR augmented using ML models with advanced algorithms can provide high diagnostic accuracy for myocarditis, even surpassing novice CMR radiologists. However, high heterogeneity, quality assessment concerns, and lack of information on cost-effectiveness may limit the clinical implementation of ML. Future investigations should explore cost-effectiveness and minimize biases in their methodologies.

22 April 2025 in Epilepsy & Behavior Reports
Verified
Journal Article
Open access
ESEshita Sharma
Eshita Sharma
BPBeatriz Westphalen Pomianoski
Beatriz Westphalen Pomianoski
RJRabbia Jabbar
Rabbia Jabbar
AAAyesha Ayesha
Ayesha Ayesha
YSYasmin Picanco Silva
Yasmin Picanco Silva
GNGiovani Noll
Giovani Noll
• Meta-analysis of 207 patients supports RNS efficacy in refractory MTLE; RNS therapy may reduce seizure frequency in patients with refractory MTLE; Some patients with MTLE achieved seizure freedom within 6 months with RNS.

11 September 2025 in Spine
Verified
Journal Article
Open access
AŁAnna Łajczak
Anna Łajczak
PŁPaweł Łajczak
Paweł Łajczak
KJKamil Jóźwik Kamil Jóźwik
Kamil Jóźwik Kamil Jóźwik
CTCristian Jaldin Torrico
Cristian Jaldin Torrico
PNPrzemysław Nowakowski
Przemysław Nowakowski
AAAyesha Ayesha
Ayesha Ayesha
Study Design.: Systematic review with meta-analysis. Objective.: This meta-analysis aims to assess robotic and conventional surgical techniques for instrumentation of the spine among pediatric, adolescent, and young adult populations. Summary of Background Data.: Spinal deformities among younger patients may be treated with pedicle screw instrumentation; however, freehand guidance often leads to screw misplacements and consequent complications. Although computer-navigation surgery improved the screw accuracy, physiological limitations of the surgeon still remain a serious challenge. Robot-assisted (RA) surgery became a novel technique for enhancing screw accuracy. Methods.: PRISMA and Cochrane Handbook were followed, and five databases were searched from inception. Studies analyzing patients aged up to 25 years old, and comparing RA to freehand or navigation were included. Outcomes included screw accuracy, perioperative outcomes, and complications. Meta-analysis was pooled with random-effects model. Results.: Finally, 10 studies, 550 patients, and 8061 screws were included in the meta-analysis. Accurate screw placement rates (grade 0: OR 2.33, P <0.001) and clinically acceptable placements (grade 0+1: OR 3.09, P <0.001) were significantly higher in robotic cohort. However, RA surgery increased operation time (MD 21.51 min, P =0.03). Blood loss, Cobb angle correction, hospital stay, or complications showed no significant differences between the two groups. Conclusions.: RA surgery leads to improved accuracy of the pedicle scores; however, this does not directly translate to better clinical or curvature outcomes. Moreover, longer operation times were observed in the robotic cohort. More high-quality studies are needed to validate these findings.