17 July 2012 in IEEE Transactions on Information Technology in Biomedicine
Verified
Journal Article
Closed access
MPMikko Peltokangas
Mikko Peltokangas
JVJarmo Verho
Jarmo Verho
AVAntti Vehkaoja
Antti Vehkaoja
A system for unobtrusive night-time electrocardiogram (EKG) and heart rate variability (HRV) monitoring as well as data analysis methods are presented, comparing bed sheet HR and HRV values with corresponding parameters obtained by a reference measurement. Our system uses eight embroidered textile electrodes attached laterally to a bed sheet for measuring bipolar contact EKG from multiple channels. The electrodes are arranged in a line so that at least two adjacent electrodes make sufficient skin contact. The focus of the signal processing development has been on selecting the best measurement channel for further analysis and minimizing the amount of incorrectly detected R-peaks. The test measurements were performed with four healthy men without previously known cardiac disorders and one who frequently had premature ventricular contractions (ectopic beats). For healthy test subjects, an average of 94.9% heartbeat detection coverage was achieved with the system during 29 measurement nights (in total 213.8 h of data). In most cases, the quality of the signal obtained from bed sheet electrodes is good enough for the computer-assisted cardiac arrhythmia detection. Applications for EKG derived RR-interval data include the calculation of HRV parameters that can be utilized in sleep quality analysis and other wellness-related topics as well as sleep apnoea detection.

24 May 2018 in Sensors
Verified
Journal Article
Open access
PDF file
MPMikko Pirhonen
Mikko Pirhonen
MPMikko Peltokangas
Mikko Peltokangas
AVAntti Vehkaoja
Antti Vehkaoja
Respiration rate (RR) provides useful information for assessing the status of a patient. We propose RR estimation based on photoplethysmography (PPG) because the blood perfusion dynamics are known to carry information on breathing, as respiration-induced modulations in the PPG signal. We studied the use of amplitude variability of transmittance mode finger PPG signal in RR estimation by comparing four time-frequency (TF) representation methods of the signal cascaded with a particle filter. The TF methods compared were short-time Fourier transform (STFT) and three types of synchrosqueezing methods. The public VORTAL database was used in this study. The results indicate that the advanced frequency reallocation methods based on synchrosqueezing approach may present improvement over linear methods, such as STFT. The best results were achieved using wavelet synchrosqueezing transform, having a mean absolute error and median error of 2.33 and 1.15 breaths per minute, respectively. Synchrosqueezing methods were generally more accurate than STFT on most of the subjects when particle filtering was applied. While TF analysis combined with particle filtering is a promising alternative for real-time estimation of RR, artefacts and non-respiration-related frequency components remain problematic and impose requirements for further studies in the areas of signal processing algorithms an PPG instrumentation.

6 May 2019 in IEEE Journal of the Electron Devices Society
Verified
Journal Article
Open access
MLMika-Matti Laurila
Mika-Matti Laurila
STShizuo Tokito
Shizuo Tokito
MMMatti Mäntysalo
Matti Mäntysalo
HMHiroyuki Matsui
Hiroyuki Matsui
RSRei Shiwaku
Rei Shiwaku
NONiku Oksala
Niku Oksala
In this contribution, we propose a fully printed charge amplifier for on-skin biosignal measurements. The amplifier is fabricated on an ultra-thin parylene substrate and consists of organic transistors, integrated bias and feedback resistors, and a feedback capacitor. The fabrication process utilizes inkjet-printed Ag ink for source, drain, gate, and capacitor electrode metallization as well as for the interconnects between the amplifier elements. Dispensed polystyrene, 2,7-dihexyl-dithieno2,3-d;2’,3’-d’benzo1,2-b;4,5-b’dithiophene (PS:DTBDT-C6), is used as the transistor channel material, dispensed poly(3-hexylthiophene) (P3HT) as the high-resistivity material for the printed resistors, and parylene as the capacitor dielectric. A pass band optimized for pulse-wave measurement (60 mHz to 36 Hz) is achieved with a maximum charge amplification of 1.6 V/nC. To demonstrate the potential of the proposed printed amplifier, a radial arterial pulsewave signal recorded with a printed piezoelectric poly(vinylidenefluoride-cotrifluoroethylene) (PVDF-TrFE) sensor was fed to it and the output was analyzed to quantify the similarity of the pulse-wave features calculated from the original signal and the amplifier output. The amplified signal contains all the essential features of a pulse wave, such as both systolic waves, the dicrotic notch, and diastolic wave, which enable the accurate derivation of the clinically relevant indices utilized in the evaluation of vascular health.

8 March 2017 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
MPMikko Peltokangas
Mikko Peltokangas
ATAnca A. Telembeci
Anca A. Telembeci
JVJarmo Verho
Jarmo Verho
VMVille M. Mattila
Ville M. Mattila
PRPekka Romsi
Pekka Romsi
NONiku Oksala
Niku Oksala
Arterial diseases are significant and increasing cause of mortality and morbidity. In this study, we analyze and compare the discrimination capability of different arterial pulse wave (PW) based indices, both earlier proposed and novel ones, for describing the vascular health. The repeatability of the indices is also evaluated. Both volume PWs and dynamic pressure PWs are recorded by using photoplethysmographic and electromechanical film (EMFi) sensors connected to a wireless body sensor network. The study population consists of 82 subjects, 30 atherosclerotic patients, and 52 control subjects. In addition, day-to-day variability of the derived indices is studied with ten test subjects examined on three different days. The results are evaluated in terms of statistical tests and receiver operating characteristic (ROC) curves as well as coefficient of variation (CV) and intraclass correlation coefficient (ICC). Altogether 24 out of the evaluated 40 PW parameters showed statistical differences (p <; 0.05 or less) between controls and atherosclerotic patients. Maximum area under curve was 0.88. Most of the indices had ICCs higher than 0.8 and average CVs less than 0.1. The study shows that the amplitude ratios and time intervals between different PW peaks could be a useful additional tool for the detection of atherosclerosis. The results encourage us for further studies in this field. Up to our knowledge, the performance and the repeatability of different PW derived indices have previously not been studied and compared with each other this extensively. Our findings also provide evidence for the utility of PW measurements for the detection of atherosclerotic changes.

13 August 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MLMika-Matti Laurila
Mika-Matti Laurila
MPMikko Peltokangas
Mikko Peltokangas
KMKarem Lozano Montero
Karem Lozano Montero
TSTuomo Siponkoski
Tuomo Siponkoski
JJJari Juuti
Jari Juuti
MMMatti Mäntysalo
Matti Mäntysalo
In this contribution, we evaluate the performance of an additively fabricated piezoelectric poly(vinylidenefluoride-cotrifluoroethylene) (P(VDF-TrFE)) based dynamic pressure sensor in non-invasive arterial pulse wave (PW) measurement. Additively fabricated piezoelectric sensors have high potential for the realization of affordable and unobtrusive PW measurement systems which could enable the long-term monitoring of patients with cardiovascular diseases (CVDs). However, the accuracy and reliability of such sensors have not been extensively studied before. We propose an additive fabrication process for a P(VDF-TrFE) PW-sensor, measure PW from the radial artery at the wrist from 22 healthy volunteer subjects, calculate clinically relevant parameters based on the PW waveform and compare their values to the values obtained from concurrent measurement with an electromechanical film (EMFi) based reference sensor, used earlier in several clinical studies. We show that the signals recorded with the two sensors, as well as the radial augmentation index (rAIx) and the stiffness index (SI) calculated from them, are in good agreement with each other. These results demonstrate that the additively fabricated P(VDF-TrFE) PW sensors can reach a suitable level of accuracy and reliability for clinical use.

11 January 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
MPMikko Peltokangas
Mikko Peltokangas
DVDamir Vakhitov
Damir Vakhitov
VSVelipekka Suominen
Velipekka Suominen
JKJanne Korhonen
Janne Korhonen
MHMatti Huotari
Matti Huotari
AVAntti Vehkaoja
Antti Vehkaoja
Objective: The aim of the study was to show if pulse rise times (PRTs) extracted from photoplethysmographic (PPG) pulse waves (PWs) have an association with peripheral arterial disease (PAD) or its endovascular treatment, percutanoeus transluminal angioplasty (PTA) of the superficial femoral artery. Methods: Lower and upper limb PPG PWs were recorded and analyzed from 24 patients who suffered from PAD. The measurements were conducted before and after the treatment, and one month later by using transmission-mode PPG-probes placed in the index finger and second toe. Ankle-to-brachial pressure index and toe pressures were used as references in clinical patient measurements. PRTs, i.e., the time from the foot point to the peak point of the PW, were extracted from the PWs and compared bilaterally. The results from the PAD patients were also compared with 31 same-aged and 34 younger control subjects. Results: Statistically significant differences were found between the pretreatment PRTs of the treated limb of the PAD patients and the same-aged control subjects ( $p< 10^{-9}$ , Mann–Whitney U-test). The changes in the PRT of the treated lower limb were observed immediately after the PTA ( $p< 0.001$ , Student's t -test), and after one month ( $p< 0.0005$ ), whereas the PRTs of the non-treated lower limb and upper limb did not indicate changes between different examinations. Conclusion: Results show that a PRT greater than 240 ms indicates PAD-lesions in the lower limb. Significance: This proof-of-concept study suggests that the PRT could be an effective and easy-to-use indicator for PAD and monitoring the effectiveness of its treatment.