Hadi Mohammed Alamri

Dr. Hadi Mohammed Alamri


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2025 in Medicina
Verified
Journal Article
Open access
PDF file
AAAlWaleed Abushanan
AlWaleed Abushanan
RSRAJASHEKHARA BHARI SHARANESHA
RAJASHEKHARA BHARI SHARANESHA
FAFahd Aljarbou
Fahd Aljarbou
HAHadi Mohammed Alamri
Hadi Mohammed Alamri
RSRAJASHEKHARA BHARI SHARANESHA
RAJASHEKHARA BHARI SHARANESHA
MMMubashir Baig Mirza
Mubashir Baig Mirza
Background and Objectives: Nickel–titanium (Niti) instruments have enhanced root canal cleaning in primary teeth, but file fractures are still common. Materials and Methods: This study evaluated the cyclic fatigue resistance of 120 Niti files from four different systems, A: Kedo SG (n = 30); B: Neoendo Pedoflex (n = 30); C: Pedoflex Waldent files (n = 30); and D: Vortex Blue files (n = 30). All the files had similar tip diameters (0.25 mm) and tapers (0.4%) and underwent heat treatment during manufacturing. Cyclic fatigue tests showed notable variations in cycles to fracture (NCF) across groups. All fracture surfaces of the files were assessed through scanning electron microscopy. Results: The mean values achieved in the experimental groups (A, B, C) were less than those in the control Group D (976.90 ± 1085.19). Files in Group A demonstrated the highest NCF (697.01 ± 420.09), while Pedoflex files in Group C showed the lowest values (203.88 ± 155.46). Statistical analysis using the Mann–Whitney test revealed significant differences between Group C and Groups A, B, and D and no differences among Groups A, B, and D. Conclusions: These findings suggest that Kedo SG and Neoendo Pedoflex files offer comparable cyclic fatigue resistance to Vortex Blue files. In contrast, Pedoflex Waldent files exhibit lower resistance to fracture.

18 March 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
AAAlWaleed Abushanan
AlWaleed Abushanan
RSRAJASHEKHARA BHARI SHARANESHA
RAJASHEKHARA BHARI SHARANESHA
FAFahd Aljarbou
Fahd Aljarbou
HAHadi Mohammed Alamri
Hadi Mohammed Alamri
RSRAJASHEKHARA BHARI SHARANESHA
RAJASHEKHARA BHARI SHARANESHA
MMMubashir Baig Mirza
Mubashir Baig Mirza
Nickel-titanium (Niti) instruments have enhanced root canal cleaning in primary teeth, but file fractures are still common. This study evaluated the cyclic fatigue resistance of 120 Niti files from four different systems, A: Kedo SG (n=30); B: Neoendo Pedoflex (n=30); C: Pedoflex Waldent files (n=30) and D: Vortex Blue files (n=30). All the files had similar tip diameters (0.25 mm) and tapers (0.4%) and underwent heat treatment during manufacturing. Cyclic fatigue tests showed notable variations in cycles to fracture (NCF) across groups. All fracture surfaces of the files were assessed through scanning electron microscopy. The mean values achieved in the experimental groups (A, B, C) were less than those in the control group D (976.90 ± 1085.19). Files in Group A demonstrated the highest NCF (697.01 ± 420.09), while Pedoflex files in Group C showed the lowest values (203.88 ± 155.46). Statistical analysis using the Mann-Whitney test revealed significant differences between groups A, B, and D compared to Group C. Still, no differences among groups A, B, and D. These findings suggest that Kedo SG and Neoendo Pedoflex files offer comparable cyclic fatigue resistance to Vortex Blue files. In contrast, Pedoflex Waldent files exhibit lower resistance to fracture.