Toan Phung

Dr. Toan Phung

School of Electrical Engineering & Telecommunications, University of New South Wales, Sydney, NSW 2052, Australia
orcid

Research Focus & Metrics

Academic Career Length

41Years (1986-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2007 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
HZHao Zhang
Hao Zhang
TBT.R. Blackburn
T.R. Blackburn
Toan PhungToan Phung
Toan Phung
DSD. Sen
D. Sen
Medium and high voltage power cables are widely used in the electrical industry with substantial growth over the last 20-30 years ago, particular in the use of XLPE insulated systems. Ageing of the cable insulation is becoming an increasing problem that requires development of reliable methods for on-line condition assessment. For insulation condition assessment of MV and HV cables, partial discharge (PD) monitoring is one of the most effective techniques. However on-site and on-line PD measurements are affected by electromagnetic interference (EMI) that makes sensitive PD detection very difficult, if not impossible. This paper describes implementation of wavelet transform techniques to reject noise from on-line partial discharge measurements on cables. A new wavelet threshold determination method is proposed with the technique. With implementation of this novel de-noising method, PD measurement sensitivity has been greatly improved. In addition, a full AC cycle data recovery can be achieved instead of focusing only on recovering individual PD pulses. Other wavelet threshold de-noising methods are discussed and examined under a noisy environment to compare their performance with the new method proposed here. The method described here has been found to be superior to the other wavelet-based methods

1 December 2012 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
HSH. H. Sinaga
H. H. Sinaga
Toan PhungToan Phung
Toan Phung
TBT. R. Blackburn
T. R. Blackburn
The location of a partial discharge (PD) source inside a transformer can be determined from the time differences of arrival (TDOA) between signals that are captured by an array of UHF sensors. The TDOA can be acquired from the received PD waveforms. In this paper, three different methods of acquiring the TDOA from the PD waveforms are discussed. The time difference can be calculated either by taking the first peak of the signal as the arrival instant, or from the cross-correlation of the PD waveforms, or by applying the similarity function to the plots of the PD signals cumulative energy. Computation algorithms for determining the TDOA automatically are introduced so that possible bias from human interpretation is avoided. The presence of noise and its effect on the accuracy of the PD localization will also be presented. Experimental results show the first-peak method has higher accuracy than the two other methods. The application of signal denoising further improves the localization accuracy.

28 February 2019 in Sensors
Verified
Journal Article
Open access
PDF file
HCHua Chai
Hua Chai
Toan PhungToan Phung
Toan Phung
SMSteve Mitchell
Steve Mitchell
Condition monitoring of an operating apparatus is essential for lifespan assessment and maintenance planning in a power system. Electrical insulation is a critical aspect to be monitored, since it is susceptible to failure under high electrical stress. To avoid unexpected breakdowns, the level of partial discharge (PD) activity should be continuously monitored because PD occurrence can accelerate the aging process of insulation in high voltage equipment and result in catastrophic failure if the associated defects are not treated at an early stage. For on-site PD detection, the ultra-high frequency (UHF) method was employed in the field and showed its effectiveness as a detection technique. The main advantage of the UHF method is its immunity to external electromagnetic interference with a high signal-to-noise ratio, which is necessary for on-site monitoring. Considering the detection process, sensors play a critical role in capturing signals from PD sources and transmitting them onto the measurement system. In this paper, UHF sensors applied in PD detection were comprehensively reviewed. In particular, for power transformers, the effects of the physical structure on UHF signals and practical applications of UHF sensors including PD localization techniques were discussed. The aim of this review was to present state-of-the-art UHF sensors in PD detection and facilitate future improvements in the UHF method.

1 October 2018 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
KFKeyvan Firuzi
Keyvan Firuzi
MVMehdi Vakilian
Mehdi Vakilian
Toan PhungToan Phung
Toan Phung
TBTrevor R. Blackburn
Trevor R. Blackburn
Partial discharge (PD) measurement and identification have great importance to condition monitoring of power transformers. In this paper, a new method for recognition of single and multi-source of PD based on extraction of high level image features has been introduced. A database, involving 365 samples of phase-resolved PD (PRPD) data, is developed by measurement carried out on transformer artificial defect models (having different sizes of defect) under a specific applied voltage, to be used for proposed algorithm validation. In the first step, each set of PRPD data is converted into grayscale images to represent different PD defects. Two “image feature extraction” methods, the Local Binary Pattern (LBP), and the Histogram of Oriented Gradient (HOG), are employed to extract features from the obtained gray scale images. Different variants of Support Vector Machine (SVM) are adjusted for optimal classification of PD sources in this process. Impact of the employed parameters in the image processing such as image resolution, random noise, and phase shift, on identification accuracy is investigated and addressed. It is shown that by using HOG-SVM method 99.3% accuracy can be achieved. This is hardly affected by various external factors. Two case studies have been conducted on multi-source PD for evaluating the performance of the proposed algorithm. A void defect is implemented into the transformer model and the resultant recorded signal is used for the study. The DBSCAN algorithm is used as the mean of PD source clustering and sub-PRPD pattern development. It is shown that HOG-SVM method has superior performance in identifying active sources, under sub-PRPD pattern application.

1 January 1995 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
RJR.E. James
R.E. James
Toan PhungToan Phung
Toan Phung
After referring briefly to the earlier developments of computer-based PD measurements in the 1970s, the paper outlines how the introduction of new technology has resulted in the design and production of a number of digital systems for use in test laboratories and on site. In order to avoid overgeneralization, the basis of the hardware required for detection and recording of the PD pulses is described by reference to a particular system, it being understood that many detailed variations are possible depending on the application. The paper describes a number of parameters that can be calculated by software and used to characterize the PD behavior. These include the IEC-270 integrated quantities, statistical moments and other fingerprints for recognizing the PD patterns within the power frequency cycle. Examples are given of the patterns obtained on equipment and samples. These are necessarily selective and are intended to indicate how the techniques may be applied. It is concluded that these new methods will become valuable in procedures for assessing the condition of electrical insulation, in particular faults or defects, but must be used in conjunction with existing techniques until improved confidence is achieved in interpreting results, especially in respect of the various phase-resolved distributions and calibration procedures.

1 July 2007
Verified
Conference Paper
Closed access
NMNor Asiah Muhamad
Nor Asiah Muhamad
Toan PhungToan Phung
Toan Phung
TBT.R. Blackburn
T.R. Blackburn
KLK.X Lai
K.X Lai
Dissolved gas-in-oil analysis (DGA) is a sensitive and reliable technique for the detection of incipient fault condition within oil-immersed transformers. The presence of certain key gases is monitored and quantified. There are a number of methods developed for analyzing these gases and interpreting their significance: Key Gas, Rogers Ratio, Doernenburg, Logarithmic Nomograph, IEC Ratio and Duval Triangle. This paper investigates the accuracy and consistency of these methods in interpreting the transformer condition. The evaluation is carried out on DGA data obtained from the local power utilities and from published papers. The data consists of 92 different cases. The key gases considered are hydrogen, methane, ethane, ethylene and acetylene. A MATLAB program was developed to automate the evaluation of the methods.