Nor Asiah Muhamad

Dr. Nor Asiah Muhamad


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2018 in Electric Power Systems Research
Verified
Journal Article
Closed access
SGSharin Ab Ghani
Sharin Ab Ghani
NMNor Asiah Muhamad
Nor Asiah Muhamad
ZNZulkarnain Ahmad Noorden
Zulkarnain Ahmad Noorden
HZHidayat Zainuddin
Hidayat Zainuddin
NBNorazhar Abu Bakar
Norazhar Abu Bakar
MTMohd Aizam Talib
Mohd Aizam Talib

6 April 2018 in IEEE Access
Verified
Journal Article
Open access
Jiashen TehJiashen Teh
Jiashen Teh
Ching-Ming LaiChing-Ming Lai
Ching-Ming Lai
NMNor Asiah Muhamad
Nor Asiah Muhamad
COChia Ai Ooi
Chia Ai Ooi
YCYu-Huei Cheng
Yu-Huei Cheng
MOHAMAD KHAIRI ISHAKMOHAMAD KHAIRI ISHAK
MOHAMAD KHAIRI ISHAK
Traditional transmission line ratings are limited by a set of fixed conservative weather assumptions that are also known as static thermal rating (STR). Owing to STR, new line corridors are continuously required to address increasing electricity demands while minimizing the curtailment of renewable energy sources (RES). However, the expansion of an electricity network is expansive, long, and limited due to the scarcity in land and space. To overcome this issue, researchers have proposed a dynamic thermal rating (DTR) system that can increase the capacity of existing transmission lines. Research has shown that actual line ratings are higher than STR most of the time. The potential of using the DTR system to increase the reliability of power systems is therefore significant. Almost every country has begun the process of increasing the integration of RES, and consequently, the DTR system has become increasingly important. Exploring and reviewing critical studies on the DTR system are thus beneficial for researchers who are interested in the developments of DTR technology. This review paper begins by comparing the two main DTR system standards. Then, monitoring technologies of the DTR system are reviewed. Notable research on the reliability impacts of the DTR system on electrical networks are surveyed. Interactions with wind power and other smart grid technologies are also examined, and the concept of power system reliability is briefly discussed.

1 September 2013 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
MSMohammed Yekini Suberu
Mohammed Yekini Suberu
MMMohd Wazir Mustafa
Mohd Wazir Mustafa
NBNouruddeen Bashir
Nouruddeen Bashir
NMNor Asiah Muhamad
Nor Asiah Muhamad
AMAhmad Safawi Mokhtar
Ahmad Safawi Mokhtar

24 September 2021 in IEEE Access
Verified
Journal Article
Open access
NRNorfadilah Rosle
Norfadilah Rosle
NMNor Asiah Muhamad
Nor Asiah Muhamad
MRMohamad Nur Khairul Hafizi Rohani
Mohamad Nur Khairul Hafizi Rohani
MJMohamad Kamarol Mohd Jamil
Mohamad Kamarol Mohd Jamil
Partial discharge (PD) signal classification analysis on cross-linked polyethylene (XLPE) cables is complex, requiring a comprehensive understanding of the characteristics of PD patterns. In the realm of high-voltage electrical insulation, PD pattern characteristics, such as PD charge and inception voltage, are essential as assessment criteria in diagnostics systems using PD classifiers. This paper provides a review of the various PD patterns and classifiers used by previous researchers, specifically for XLPE cables. In addition, the differences of the studies on various sensor developments based on PD detection in the past 27 years are also discussed. The repeatability, recognition accuracy, recognition speed, and effect of feature sizes on each PD classification method are reviewed and explained. This review indicates that the pattern recognition for PD signal using artificial neural network (ANN) exhibits better performance than the other methods in terms of accuracy and repeatability, and the reduction of feature size does not affect the accuracy of ANN.

1 July 2007
Verified
Conference Paper
Closed access
NMNor Asiah Muhamad
Nor Asiah Muhamad
Toan PhungToan Phung
Toan Phung
TBT.R. Blackburn
T.R. Blackburn
KLK.X Lai
K.X Lai
Dissolved gas-in-oil analysis (DGA) is a sensitive and reliable technique for the detection of incipient fault condition within oil-immersed transformers. The presence of certain key gases is monitored and quantified. There are a number of methods developed for analyzing these gases and interpreting their significance: Key Gas, Rogers Ratio, Doernenburg, Logarithmic Nomograph, IEC Ratio and Duval Triangle. This paper investigates the accuracy and consistency of these methods in interpreting the transformer condition. The evaluation is carried out on DGA data obtained from the local power utilities and from published papers. The data consists of 92 different cases. The key gases considered are hydrogen, methane, ethane, ethylene and acetylene. A MATLAB program was developed to automate the evaluation of the methods.

1 May 2016 in Energy
Verified
Journal Article
Closed access
KLK.Y. Lau
K.Y. Lau
NMNor Asiah Muhamad
Nor Asiah Muhamad
YAYanuar Z. Arief
Yanuar Z. Arief
CTC.W. Tan
C.W. Tan
AYA.H.M. Yatim
A.H.M. Yatim