Jiongyi Zhu

Dr. Jiongyi Zhu


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2020 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
GWGefei Wu
Gefei Wu
WLWeiqun Lin
Weiqun Lin
XDXiaoqing Du
Xiaoqing Du
CSChunlin Shi
Chunlin Shi
JZJiongyi Zhu
Jiongyi Zhu
To investigate the flow characteristics of the biased gap flow and the flip-flopping phenomenon at high Reynolds numbers, large-eddy simulation is adopted to simulate the crossflow around two side-by-side circular cylinders at Re = 1.4 × 105. The center-to-center pitch ratio P/D varies from 1.1 to 4. Three flow patterns, i.e., single bluff body regime, biased gap flow regime, and coupled vortex regime, have been successfully simulated. A tri-stable flow pattern is found at P/D = 1.1; namely, a single bluff body regime and a biased gap flow regime deflected to the upper or lower cylinder occur spontaneously and intermittently. In contrast to the results obtained at low Reynolds numbers, two distinct biased gap flow structures are observed at P/D = 1.2 and 1.5, respectively. For P/D = 1.2, the gap-side shear layer separated from the narrow wake cylinder further reattaches to the cylinder; namely, a series of separation bubbles would develop along the gap-side surface of the cylinder. These unsteady separation bubbles induce the inward-directed lift force on the cylinder. For P/D = 1.5, the gap-side shear layer separates directly without further reattachment, and both cylinders experience outward lift forces. It is revealed that the flip-flopping of the biased gap flow is associated with the interaction of the gap vortices and the vortex shed from the outer-side shear layer of the wide wake cylinder. Furthermore, the flip-flopping phenomenon arises initially at one particular cross section of the cylinder, rather than occurring simultaneously along the spanwise direction of the cylinder.

6 August 2024 in International Journal of Concrete Structures and Materials
Verified
Journal Article
Open access
PDF file
JZJun-Jie Zeng
Jun-Jie Zeng
XLXin-Chao Lin
Xin-Chao Lin
SFSheng-Zhao Feng
Sheng-Zhao Feng
JZJiongyi Zhu
Jiongyi Zhu
YZYan Zhuge
Yan Zhuge
YYYihang Yan
Yihang Yan
Ultra-high performance engineered cementitious composite (UHP-ECC), which is known for its exceptional compressive strength, tensile strength, and ductility, has been emerged as a promising option for repairing and strengthening reinforced concrete (RC) structures. The bond between UHP-ECC and normal concrete is the key issue for the material to be successfully implemented. This paper presents an experimental investigation focused on understanding the tensile and shear behavior of the bonding interface between UHP-ECC and concrete. A total of 78 specimens were prepared and tensile splitting tests and push-out tests were carried out. The study examined key parameters including the strength of the concrete substrate, the roughness of the interface, and the moisture condition at the interface. Various failure modes are observed in the specimens under tensile splitting force and direct shear force, and it is found that the influence of the key parameters varied depending on the type of failure mode. In specimens experiencing full interface debonding or interface failure combined with substrate cracks, the roughness of the interface and the moisture degree have a significant impact on the tensile and shear strength. Conversely, in specimens with full substrate disruption, the strength of the substrates plays a more significant role. Additionally, the study reveals that the grooving treatment is highly effective in improving the shear strength of the interface, but its impact on enhancing the tensile strength is comparatively less pronounced. Prediction models for the tensile and shear strength of the interface are established and verified against the test results. The proposed models provide valuable insights into the behavior of the UHP-ECC to concrete interface and can aid in predicting its performance in practical applications.

22 April 2025 in Sensors
Verified
Journal Article
Open access
PDF file
JZJiongyi Zhu
Jiongyi Zhu
ZHZixin Huang
Zixin Huang
DWDejiang Wang
Dejiang Wang
PLPanpan Liu
Panpan Liu
HJHaili Jiang
Haili Jiang
XDXiaoqing Du
Xiaoqing Du
The accurate installation position of corrugated pipes is critical for ensuring the quality of prestressed concrete box girders. Given that these pipes can span up to 30 m and are deeply embedded within rebars, manual measurement is both labor-intensive and prone to errors. Meanwhile, automated recognition and measurement methods are hindered by high equipment costs and accuracy issues caused by rebar occlusion. To balance cost effectiveness and measurement accuracy, this paper proposes a method that utilizes an RGB-D camera and deep learning. Firstly, an optimal registration scheme is selected to generate complete point cloud data of pipes from segmented data captured by an RGB-D camera. Next, semantic segmentation is applied to extract the characteristic features of the pipes. Finally, the center points from cross-sectional slices are extracted and curve-fitting is performed to recognize and measure the pipes. A test was conducted in a simulated precast factory environment to validate the proposed method. The results show that under the optimal fitting scheme (BP neural network with circle fitting constraint), the average measurement errors for the three pipes are 2.2 mm, 1.4 mm, and 1.6 mm, with Maximum Errors of −5.8 mm, −4.2 mm, and −5.7 mm, respectively, meeting the standard requirements. The proposed method can accurately locate the pipes, offering a new technical pathway for the automated recognition and measurement of pipes in prefabricated construction.

9 September 2025 in Thin-Walled Structures
Verified
Journal Article
Closed access
HLHaixin Liu
Haixin Liu
JZJiongyi Zhu
Jiongyi Zhu
JCJunbo Chen
Junbo Chen
TCTak Ming Chan
Tak Ming Chan

5 September 2025 in Engineering Failure Analysis
Verified
Journal Article
Closed access
YLYangqing Liu
Yangqing Liu
ZWZhonglin Wang
Zhonglin Wang
ZCZewen Chen
Zewen Chen
LZLei Zhang
Lei Zhang
JZJiongyi Zhu
Jiongyi Zhu
XDXiaoqing Du
Xiaoqing Du

9 April 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
JZJiongyi Zhu
Jiongyi Zhu
CTChenxuan Tan
Chenxuan Tan
HLHaixin Liu
Haixin Liu
JZJun-Jie Zeng
Jun-Jie Zeng
Engineered Cementitious Composite (ECC) is a class of cement-based materials characterized by significantly higher tensile strength and ductility than ordinary concrete. However, its constructability limitations and high cost restrict its widespread application. To retain its superior mechanical properties while improving economic feasibility, this paper introduces a prefabricated ECC permanent formwork, which serves as a structural layer in service, and works synergistically with the internal concrete. In this paper, a series of four-point bending tests was carried out on six reinforced concrete slabs to evaluate the effects of ECC permanent formwork thickness and interface configuration on flexural behavior. The experimental investigation demonstrates that ECC permanent formwork significantly enhances the cracking load, ultimate bearing capacity, stiffness, and crack propagation behavior of reinforced concrete slabs. Specifically, crack propagation is delayed, a more uniform crack distribution is achieved, and the flexural capacity is increased by 43%. A three-dimensional finite element model incorporating interfacial bonding and ECC strain-hardening behavior has been developed and validated by the test results. Parametric analysis further shows that the flexural capacity increases with ECC formwork thickness, but the improvement becomes less pronounced beyond 80 mm. Finally, a theoretical formula is proposed to predict the flexural capacity of ECC-concrete composite slabs.