Yuwei Wang

Mr. Yuwei Wang


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 September 2022 in Sensors
Verified
Journal Article
Open access
PDF file
KLKaichao Lei
Kaichao Lei
Xin YeXin Ye
Xin Ye
ZXZhiwei Xia
Zhiwei Xia
NXNan Xu
Nan Xu
SLShuqi Li
Shuqi Li
ZLZhigang Li
Zhigang Li
In order to meet the high-accuracy calibration requirements of satellite remote sensing instruments, a transfer radiometer for an on-orbit radiometric benchmark transfer chain has been developed, which provides vital technical support for realizing the radiometric calibration uncertainty of the order of 10−3 for remote sensing instruments. The primary role of the transfer radiometer is to convert from the spectral power responsivity traceable to a cryogenic radiometer to the spectral radiance responsivity and transfer it to the imaging spectrometer. At a wavelength of 852.1 nm, the combined uncertainty of the radiance measurement comparison experiment between the transfer radiometer and a radiance meter is 0.43% (k = 1), and the relative deviation of the measurements between the transfer radiometer and the radiance meter is better than 0.36%, which is better than the combined uncertainty of the radiance measurement comparison experiment. This demonstrates that the transfer radiometer can achieve radiance measurements with a measurement uncertainty better than 0.3% (k = 1).

6 June 2024 in Remote Sensing
Verified
Journal Article
Open access
PDF file
HZHanyuan Zhang
Hanyuan Zhang
Xin YeXin Ye
Xin Ye
DWDuo Wu
Duo Wu
YWYuwei Wang
Yuwei Wang
DYDongjun Yang
Dongjun Yang
WFWei Fang
Wei Fang
The non-scanning radiometer with short-wavelength (SW: 0.2–5.0 μm) and total-wavelength (TW: 0.2–50.0 μm) channels is the primary payload of the Integrated Earth–Moon Radiation Observation System (IEMROS), which is designed to provide comprehensive Earth radiation measurements and lunar calibrations at the L1 Lagrange point of the Earth–Moon system from a global perspective. This manuscript introduces a radiometer preflight calibration methodology, which involves background removal and is validated using accurate and traceable reference sources. Simulated Earth view tests are performed to evaluate repeatability, linearity, and gain coefficients over the operating range. Both channels demonstrate repeatability uncertainties better than 0.34%, indicating consistent and reliable measuring performance. Comparative polynomial regression analysis confirms significant linear response characteristics with two-channel nonlinearity less than 0.20%. Gain coefficients are efficiently determined using a two-point calibration approach. Uncertainty analysis reveals an absolute radiometric calibration accuracy of 0.97% for the SW channel and 0.92% for the TW channel, underscoring the non-scanning radiometer’s capability to provide dependable global Earth radiation budget data crucial to environmental and climate studies.

5 July 2024 in Sensors
Verified
Journal Article
Open access
PDF file
JFji ze Fan
ji ze Fan
YWYuwei Wang
Yuwei Wang
GGGuochao Gu
Guochao Gu
ZLZhe Li
Zhe Li
XWXiaoxu Wang
Xiaoxu Wang
DHDenghui Hu
Denghui Hu
Hyperspectral detection of the change rate of organic matter content in agricultural remote sensing requires a high signal-to-noise ratio (SNR). However, due to the large number and efficiency limitation of the components, it is difficult to improve the SNR. This study uses high-efficiency convex grating with a diffraction efficiency exceeding 50% across the 360–850 nm range, a back-illuminated Complementary Metal Oxide Semiconductor (CMOS) detector with a 95% efficiency in peak wavelength, and silver-coated mirrors to develop an imaging spectrometer for detecting soil organic matter (SOM). The designed system meets the spectral resolution of 10 nm in the 360–850 nm range and achieves a swath of 100 km and a spatial resolution of 100 m at an orbital height of 648.2 km. This study also uses the basic structure of Offner with fewer components in the design and sets the mirrors of the Offner structure to have the same sphere, which can achieve the rapid adjustment of the co-standard. This study performs a theoretical analysis of the developed Offner imaging spectrometer based on the classical Rowland circular structure, with a 21.8 mm slit length; simulates its capacity for suppressing the +2nd-order diffraction stray light with the filter; and analyzes the imaging quality after meeting the tolerance requirements, which is combined with the surface shape characteristics of the high-efficiency grating. After this test, the grating has a diffraction efficiency above 50%, and the silver-coated mirrors have a reflection value above 95% on average. Finally, the laboratory tests show that the SNR over the waveband exceeds 300 and reaches 800 at 550 nm, which is higher than some current instruments in orbit for soil observation. The proposed imaging spectrometer has a spectral resolution of 10 nm, and its modulation transfer function (MTF) is greater than 0.23 at the Nyquist frequency, making it suitable for remote sensing observation of SOM change rate. The manufacture of such a high-efficiency broadband grating and the development of the proposed instrument with high energy transmission efficiency can provide a feasible technical solution for observing faint targets with a high SNR.

7 February 2023 in Photonics
Verified
Journal Article
Open access
PDF file
KLKaichao Lei
Kaichao Lei
Xin YeXin Ye
Xin Ye
NXNan Xu
Nan Xu
SLShuqi Li
Shuqi Li
YZYachao Zhang
Yachao Zhang
ZLZhigang Li
Zhigang Li
A transfer radiometer (TR) applied to an on-orbit radiometric benchmark transfer chain has been developed, which can achieve the high-precision transformation of power and radiance responsivity and transmit the radiance responsivity traced to the cryogenic radiometer to remote sensors, such as an imaging spectrometer, so that the on-orbit remote sensors can achieve the high accuracy calibration of 10−3 magnitude. Radiance comparison experiments between the TR and the radiance standard of the National Institute of Metrology (NIM) were carried out to demonstrate the absolute accuracy of the TR radiance measurement. At 780.0 nm and 851.9 nm, the relative measurement uncertainties of the TR filter-free channel were 0.24% (k = 1). Additionally, the radiance measurement results of the TR were consistent with those of the NIM radiance meter, and the radiance measurement results’ relative differences between the TR and the NIM radiance meter were approximately 0.04% at 780.0 nm and 851.9 nm. The relative measurement uncertainties of TR 780.4 nm and 851.8 nm filter channels were 0.89% (k = 1) and 0.84% (k = 1), respectively. Additionally, the radiance measurement results of the TR 780.4 nm and 851.8 nm filter channels were consistent with the radiances of the integrating sphere source calibrated by the NIM at 780.4 nm and 851.8 nm; the relative differences between the radiances measured by the two TR filter channels and the radiances of the integrating sphere source itself were better than 0.56%. This proved that the TR could measure the monochromatic source radiance with a measurement uncertainty of 0.24% and measure the broadband source radiance with a measurement uncertainty better than 0.89%. The TR can be applied to the radiometric benchmark transfer chain to improve the measurement precision of on-orbit remote-sensing instruments.

13 June 2023 in Remote Sensing
Verified
Journal Article
Open access
PDF file
DWDuo Wu
Duo Wu
WFWei Fang
Wei Fang
KWKai Wang
Kai Wang
Xin YeXin Ye
Xin Ye
RJRuidong Jia
Ruidong Jia
MRMichel van Ruymbeke
Michel van Ruymbeke
In order to simultaneously determine the values of total solar irradiance (TSI) and the Earth’s radiation at the top of the atmosphere (TOA) on board the Fengyun-3F satellite, a spaceborne relative radiometer (SRR) was developed. It adopts a dual-channel structure, including a solar radiometer channel (SR) with an unobstructed field of view (FOV) of 1.5° and an Earth radiometer channel (ER) with a wide field of view (WFOV) of 95.3° and a diameter of about 1900 km on the ground. Before the launch, both the SR and ER were calibrated. The SR, installed on the inner frame of the solar tracker of the SIM-II (solar irradiance monitor-II), is used to observe rapid changes in solar radiance with the SIAR (solar irradiance absolute radiometer), an electrical-substitution radiometer, on orbit. The ER is mounted on the U-shaped frame of the solar tracker, directly pointing in the nadir direction. Additionally, a dark space observation mode is used to determine the on-orbit background noise and lunar observation mode for on-orbit calibration. In this article, the instrument design and working principle of the SRR is first introduced, and an analysis of the measurement model of the ER, the WFOV channel of the SRR, is focused on. Finally, ground test results of the SRR are introduced.

23 September 2024 in Remote Sensing
Verified
Journal Article
Open access
PDF file
SLShuqi Li
Shuqi Li
ZLZhitao Luo
Zhitao Luo
YLYanfeng Liu
Yanfeng Liu
WFWei Fang
Wei Fang
YWYuwei Wang
Yuwei Wang
Xin YeXin Ye
Xin Ye
This research project envisions using a lunar observation platform to measure the full-wave (0.2~100 μm) and shortwave (0.2~4.3 μm) radiation of the Earth, achieving an accurate estimation of the overall radiation budget of the Earth. Based on the lunar platform, the system analyzes Earth’s radiation characteristics and geometric attributes, as well as the sampling properties of observation times. Informed by these analyses, an Earth-facing optical radiation measurement system tailored to these specifications is designed. The optical system adopts an off-axis three-mirror configuration with a secondary image plane, incorporating a field stop at the primary image plane to effectively suppress solar stray light, scattered lunar surface light, and background radiation from the instrument itself, ensuring the satisfactory signal-to-noise ratio, detection sensitivity, and observation duration of the instrument. At the same time, stringent requirements are imposed for the surface treatments of instrument components and temperature control accuracy to further ensure accuracy. Simulation analyses confirm that the design satisfies requirements, achieving a measurement accuracy of better than 1% across the entire optical system. This Moon-based Earth-radiation measurement system, with capabilities for Earth-pointing tracking, radiation energy detection, and stray-light suppression, furnishes a more comprehensive dataset, helping to advance our understanding of the mechanisms driving global climate change