Hae Dong Park

Dr. Hae Dong Park

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2018 in Annals of Occupational and Environmental Medicine
Verified
Journal Article
Open access
PDF file
MSMu Young Shin
Mu Young Shin
JPJong Soo Park
Jong Soo Park
HPHae Dong Park
Hae Dong Park
JLJihye Lee
Jihye Lee
Exposure to sustained high concentrations of HCFC-123 is known to be hepatotoxic. We report two simultaneous cases of toxic hepatitis related to exposure to 2,2-dichloro-1,1,1-trifluoroethane (HCFC-123), a common refrigerant, at a Korean fire extinguisher manufacturing facility. Patients A and B were men aged 21 and 22 years, respectively, with no notable medical histories. They had recently started working for a manufacturer of fire extinguishers. During the third week of their employment, they visited the emergency center of a general hospital due to fever, lack of appetite, and general weakness. At the time of their visit, they were suspected as having hepatitis due to elevated aspartate aminotransferase (AST), alanine aminotransferase (ALT), alkaline phosphatase (ALP), gamma-glutamyl transferase (GGT), and total bilirubin levels and were hospitalized. However, as their condition did not improve, they were moved to a tertiary general hospital. After conservative treatment, one patient improved but the other died from acute hepatic failure. Assessments of the work environment showed that the short-term exposure levels of HCFC-123 for valve assembly processes were as high as 193.4 ppm. A transjugular liver biopsy was performed in patient A; the results indicated drug/toxin-induced liver injury (DILI). Given the lack of a medical history and the occupational exposure to high levels of HCFC-123, a hepatotoxic agent, the toxic hepatitis of the workers was likely related to HCFC-123 exposure. Work environment assessments have not included this agent. To the best of our knowledge, we are the first to report a case of death related to HCFC-123-induced liver damage. Our findings suggest that exposure standards and limits for HCFC-123 must be developed in Korea; work environments will have to be improved based on such standards.

22 May 2025 in Fire
Verified
Journal Article
Open access
PDF file
SKSungho Kim
Sungho Kim
HPHae Dong Park
Hae Dong Park
HPHyunhee Park
Hyunhee Park
JKJiwoon Kwon
Jiwoon Kwon
KJKihyo Jung
Kihyo Jung
Firefighters experience high noise levels from various sources, such as sirens, alarms, pumps, and emergency vehicles. Unlike industrial workers who experience continuous noise exposure, firefighters are subject to intermittent high-intensity noise, increasing their risk of noise-induced hearing loss (NIHL). Despite global concerns regarding firefighters’ auditory health, research on Korean firefighters remains limited. This study aimed to assess personal noise exposure among Korean firefighters across three primary job roles—fire suppression, rescue, and emergency medical services (EMS)—and to predict worst-case noise exposure scenarios. This study included 115 firefighters from three fire stations (one urban, two suburban). We measured personal noise exposure using dosimeters attached near the ear following the Korean Ministry of Employment and Labor (MOEL) and International Organization for Standardization (ISO) criteria. Measurements included threshold levels of 80 dBA, exchange rates of 5 dB (MOEL) and 3 dB (ISO), and a peak noise criterion of 140 dBC. We categorized firefighters’ activities into routine tasks (shift handovers, equipment checks, training) and emergency responses (fire suppression, rescues, EMS calls). We performed statistical analyses to compare noise levels across job roles, vehicle types, and specific tasks. The worst-case exposure scenarios were estimated using 10th percentile recorded noise levels. The average 8 h time-weighted noise exposure levels varied significantly by job role. Rescue personnel exhibited the highest mean noise exposure (MOEL: 71.4 dBA, ISO: 81.2 dBA; p < 0.05), whereas fire suppression (MOEL: 66.5 dBA, ISO: 74.2 dBA) and EMS personnel (MOEL: 68.6 dBA, ISO: 73.0 dBA) showed no significant difference. Peak noise levels exceeding 140 dBC were most frequently observed in rescue operations (33.3%), followed by fire suppression (30.2%) and EMS (27.2%). Among vehicles, noise exposure was the highest for rescue truck occupants. Additionally, EMS personnel inside ambulances had significantly higher noise levels than drivers (p < 0.05). Certain tasks, including shift handovers, equipment checks, and firefighter training, recorded noise levels exceeding 100 dBA. Worst-case scenario predictions indicated that some work conditions could lead to 8 h average exposures surpassing MOEL (91.4 dBA) and ISO (98.7 dBA) limits. In this study, Korean firefighters exhibited relatively low average noise levels. However, when analyzing specific tasks, exposure was sufficiently high enough to cause hearing loss. Despite NIHL risks, firefighters rarely used hearing protection, particularly during routine tasks. This emphasizes the urgent need for hearing conservation programs, including mandatory hearing protection during high-noise activities, noise exposure education, and the adoption of communication-friendly protective devices. Future research should explore long-term auditory health outcomes and assess the effectiveness of noise control measures.