Jiwoon Kwon

Dr. Jiwoon Kwon


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2026 in BMC Public Health
Verified
Journal Article
Open access
PDF file
JKJiwoon Kwon
Jiwoon Kwon
Firefighters are repeatedly exposed to hazardous combustion byproducts, and exposure-control practices are important for reducing occupational carcinogen e

14 July 2026 in Scientific Reports
Verified
Journal Article
Open access
JKJiwoon Kwon
Jiwoon Kwon
WKWon Kim
Won Kim
ICInja Choi
Inja Choi
This study investigated surface polycyclic aromatic hydrocarbon (PAH) contamination in fire stations using 121 wipe samples collected from indoor spaces, vehicles, and personal protective equipment (PPE) surfaces in three fire stations in South Korea, and identified key exposure sources in vehicles and PPE. Fire station surfaces exhibited significantly higher PAH concentrations than commercial office controls, with median total PAH (Σ17 PAHs) levels 69 times higher in fire vehicles (p < 0.001), 26 times higher in vehicle bays and PPE cabinets (both p = 0.044), and 24 times higher in fire offices (p = 0.003). Among vehicles, fire survey vehicles showed the highest surface Σ17 PAHs contamination, particularly on floors, where concentrations were significantly higher than those on seats (p = 0.021) and ceilings (p = 0.012). PPE contamination was highest on the outer ankle areas of boots, followed by gloves and boot soles. Notably, the inner surfaces of turnout pants and face shields had PAH levels comparable to those on their respective outer surfaces (p > 0.05), suggesting possible contaminant transfer, although inward contaminant infiltration could not be excluded. High-molecular-weight PAHs were more prevalent on vehicle floors and boot surfaces, indicating significant surface-associated exposure potential. These findings support the need for improved contamination control measures, including routine decontamination of vehicles and PPE, enhanced PPE design to minimize pollutant ingress, and targeted policy interventions to safeguard firefighter health.

22 May 2025 in Fire
Verified
Journal Article
Open access
PDF file
SKSungho Kim
Sungho Kim
HPHae Dong Park
Hae Dong Park
HPHyunhee Park
Hyunhee Park
JKJiwoon Kwon
Jiwoon Kwon
KJKihyo Jung
Kihyo Jung
Firefighters experience high noise levels from various sources, such as sirens, alarms, pumps, and emergency vehicles. Unlike industrial workers who experience continuous noise exposure, firefighters are subject to intermittent high-intensity noise, increasing their risk of noise-induced hearing loss (NIHL). Despite global concerns regarding firefighters’ auditory health, research on Korean firefighters remains limited. This study aimed to assess personal noise exposure among Korean firefighters across three primary job roles—fire suppression, rescue, and emergency medical services (EMS)—and to predict worst-case noise exposure scenarios. This study included 115 firefighters from three fire stations (one urban, two suburban). We measured personal noise exposure using dosimeters attached near the ear following the Korean Ministry of Employment and Labor (MOEL) and International Organization for Standardization (ISO) criteria. Measurements included threshold levels of 80 dBA, exchange rates of 5 dB (MOEL) and 3 dB (ISO), and a peak noise criterion of 140 dBC. We categorized firefighters’ activities into routine tasks (shift handovers, equipment checks, training) and emergency responses (fire suppression, rescues, EMS calls). We performed statistical analyses to compare noise levels across job roles, vehicle types, and specific tasks. The worst-case exposure scenarios were estimated using 10th percentile recorded noise levels. The average 8 h time-weighted noise exposure levels varied significantly by job role. Rescue personnel exhibited the highest mean noise exposure (MOEL: 71.4 dBA, ISO: 81.2 dBA; p < 0.05), whereas fire suppression (MOEL: 66.5 dBA, ISO: 74.2 dBA) and EMS personnel (MOEL: 68.6 dBA, ISO: 73.0 dBA) showed no significant difference. Peak noise levels exceeding 140 dBC were most frequently observed in rescue operations (33.3%), followed by fire suppression (30.2%) and EMS (27.2%). Among vehicles, noise exposure was the highest for rescue truck occupants. Additionally, EMS personnel inside ambulances had significantly higher noise levels than drivers (p < 0.05). Certain tasks, including shift handovers, equipment checks, and firefighter training, recorded noise levels exceeding 100 dBA. Worst-case scenario predictions indicated that some work conditions could lead to 8 h average exposures surpassing MOEL (91.4 dBA) and ISO (98.7 dBA) limits. In this study, Korean firefighters exhibited relatively low average noise levels. However, when analyzing specific tasks, exposure was sufficiently high enough to cause hearing loss. Despite NIHL risks, firefighters rarely used hearing protection, particularly during routine tasks. This emphasizes the urgent need for hearing conservation programs, including mandatory hearing protection during high-noise activities, noise exposure education, and the adoption of communication-friendly protective devices. Future research should explore long-term auditory health outcomes and assess the effectiveness of noise control measures.