Betina Hinckel

Dr. Betina Hinckel


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2015 in Skeletal Radiology
Verified
Journal Article
Closed access
PDF file
BHBetina Hinckel
Betina Hinckel
RGRiccardo Gomes Gobbi
Riccardo Gomes Gobbi
EFEduardo Noda Kihara Filho
Eduardo Noda Kihara Filho
JPJosé Ricardo Pécora
José Ricardo Pécora
GCGilberto Luis Camanho
Gilberto Luis Camanho
MDMarco Kawamura Demange
Marco Kawamura Demange

31 March 2016 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Closed access
PDF file
BHBetina Hinckel
Betina Hinckel
RGRiccardo G. Gobbi
Riccardo G. Gobbi
EFEduardo N. Kihara Filho
Eduardo N. Kihara Filho
MDMarco Kawamura Demange
Marco Kawamura Demange
JPJosé Ricardo Pécora
José Ricardo Pécora
GCGilberto Luis Camanho
Gilberto Luis Camanho

31 August 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
Nuno A. T. C. FernandesNuno A. T. C. Fernandes
Nuno A. T. C. Fernandes
SHIVAM SHARMASHIVAM SHARMA
SHIVAM SHARMA
AAAna Arieira
Ana Arieira
BHBetina Hinckel
Betina Hinckel
Filipe SilvaFilipe Silva
Filipe Silva
ÓCÓscar Samuel Novais Carvalho
Óscar Samuel Novais Carvalho
Ultrasonic wave attenuation in biological tissues arises from complex interactions between mechanical, structural, and fluidic properties, making it essential to identify dominant mechanisms for accurate simulation and device design. This work introduces a novel integration of experimentally measured tissue parameters into time-explicit nonlinear acoustic wave simulations, in which the equations are directly solved in the time domain using an explicit solver. This approach captures the full transient waveform without relying on frequency-domain simplifications, offering a more realistic representation of ultrasound propagation in heterogeneous media. The study estimates both sound diffusivity and viscous damping parameters (dynamic and bulk viscosity) for a broad range of ex vivo tissues (skin, adipose tissue, skeletal muscle, trabecular/cortical bone, liver, myocardium, kidney, tendon, ligament, cartilage, and gray/white brain matter). Four regression models (power law, linear, exponential, logarithmic) were applied to characterize their frequency dependence between 0.5 and 5 MHz. Results show that attenuation is more strongly driven by bulk viscosity than dynamic viscosity, particularly in fluid-rich tissues such as liver and myocardium, where compressional damping dominates. The power-law model consistently provided the best fit for all attenuation metrics, revealing a scale-invariant frequency relationship. Tissues such as cartilage and brain showed weaker viscous responses, suggesting the need for alternative modeling approaches. These findings not only advance fundamental understanding of attenuation mechanisms but also provide validated parameters and modeling strategies to improve predictive accuracy in therapeutic ultrasound planning and the design of non-invasive, tissue-specific acoustic devices.

25 June 2025 in Rheumato
Verified
Journal Article
Open access
PDF file
Nuno A. T. C. FernandesNuno A. T. C. Fernandes
Nuno A. T. C. Fernandes
AAAna Arieira
Ana Arieira
BHBetina Hinckel
Betina Hinckel
Filipe SilvaFilipe Silva
Filipe Silva
ÓCÓscar Samuel Novais Carvalho
Óscar Samuel Novais Carvalho
ALAna Leal
Ana Leal
Background/Objectives: This review analyzes the effects of invasive and non-invasive methods of knee joint unloading on knee loading, employing a biomechanical model to evaluate their impact. Methods: PubMed, Web of Science, Cochrane, and Scopus were searched up to 15 May 2024 to identify eligible clinical studies evaluating Joint Space Width, Cartilage Thickness, the Western Ontario and McMaster Universities Osteoarthritis Index, the Knee Injury and Osteoarthritis Outcome Score system, Gait velocity, Peak Knee Adduction Moment, time to return to sports and to work, ground reaction force, and the visual analogue scale pain score. A second search was conducted to select a biomechanical model that could be parametrized, including the modifications that each treatment would impose on the knee joint and was capable of estimate joint loading to compare the effectiveness of each method. Results: Analyzing 28 studies (1652 participants), including 16 randomized clinical trials, revealed significant improvements mainly when performing knee joint distraction surgery, increasing Joint Space Width even after removal, and high tibial osteotomy, which realigns the knee but does not reduce loading. Implantable shock absorbers are also an attractive option as they partially unload the knee but require further investigation. Non-invasive methods improve biomechanical indicators of knee joint loading; however, they lack quantitative analysis of cartilage volume or Joint Space Width. Conclusions: Current evidence indicates a clear advantage in knee joint unloading methods, emphasizing the importance of adapted therapy. However, more extensive research, particularly using non-invasive approaches, is required to further understand the underlying knee joint loading mechanisms and advance the state of the art.

22 August 2023 in Journal of ISAKOS
Verified
Journal Article
Open access
RDRobert S. Dean
Robert S. Dean
BHBritanny A. Hamama
Britanny A. Hamama
LCLeonardo Cavinatto
Leonardo Cavinatto
SNShane J. Nho
Shane J. Nho
JCJorge Chahla
Jorge Chahla
BHBetina Hinckel
Betina Hinckel
Heterotrophic ossification (HO) is a known complication diagnosed following hip arthroscopy. This study sought to review the current literature on chemoprophylaxis for HO following hip arthroscopy and to describe what agents and doses are being utilized. Systematic Review. A systematic review was performed according to PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analysis) guidelines on the use of chemoprophylactic medications for HO prevention following hip arthroscopy. Mechanical and radiation prophylaxis were not included in the current analysis. A total of 203 studies were identified, of which 15 were included with 6463 patients. There was one randomized control trial (RCT) and 4 additional comparative studies. The most commonly utilized chemoprophylactic agents were the following: naproxen (n=8), celecoxib (n=3), indomethacin (n=3), aspirin (n=1), etoricoxib (n=1), and etodolac (n=1), and non-specific Non-Steroidal Anti-Inflammatory Drugs (NSAIDs) (n=1). Naproxen was either given at a dose of 500 mg once or twice daily for 2 to 4 weeks. RCTs and additional comparative studies showed significant HO prevention using chemoprophylactic agents following hip arthroscopy. Heterotopic ossification is a known and common complication following hip arthroscopy. The current systematic review found significant heterogeneity across the literature with respect to specific chemoprophylactic agents and their dosing regimens aimed to reduce the incidence and severity of HO following hip arthroscopy. Additionally, this review demonstrates that most studies that utilize chemoprophylaxis use NSAIDs with successful reduction in the incidence of HO.

Verified
Journal Article
Open access
PDF file
Nuno A. T. C. FernandesNuno A. T. C. Fernandes
Nuno A. T. C. Fernandes
DADiana I. Alves
Diana I. Alves
DFDiana Ferreira
Diana Ferreira
MMMaria Monteiro
Maria Monteiro
AAAna Arieira
Ana Arieira
ÓCÓscar Samuel Novais Carvalho
Óscar Samuel Novais Carvalho
Medical phantoms are essential to imaging calibration, clinician training, and the validation of therapeutic procedures. However, most ultrasound phantoms prioritize acoustic realism while neglecting the viscoelastic and anisotropic properties of fibrous soft tissues. This gap limits their effectiveness in modeling realistic biomechanical behavior, especially in wave-based diagnostics and therapeutic ultrasound. Current materials like gelatine and agarose fall short in reproducing the complex interplay between the solid and fluid components found in biological tissues. To address this, we developed a soft, anisotropic composite whose dynamic mechanical properties resemble fibrous biological tissues such as skin and skeletal muscle. This material enables wave propagation and vibration studies in controllably anisotropic media, which are rare and highly valuable. We demonstrate the tunability of damping and stiffness aligned with fiber orientation, providing a versatile platform for modeling soft-tissue dynamics and validating biomechanical simulations. The phantoms achieved Young’s moduli of 7.16–11.04 MPa for skin and 0.494–1.743 MPa for muscles, shear wave speeds of 1.51–5.93 m/s, longitudinal wave speeds of 1086–1127 m/s, and sound absorption coefficients of 0.13–0.76 dB/cm/MHz, with storage, loss, and complex moduli reaching 1.035–6.652 kPa, 0.1831–0.8546 kPa, and 2.138–10.82 kPa. These values reveal anisotropic response patterns analogous to native tissues. This novel natural fibrous composite system affords sustainable, low-cost ultrasound phantoms that support both mechanical fidelity and acoustic realism. Our approach offers a route to next-gen tissue-mimicking phantoms for elastography, wave propagation studies, and dynamic calibration across diverse clinical and research applications.