Foundation pit pumping induces groundwater drawdown both inside and outside the pit, consequently causing surrounding land subsidence. Based on actual engineering cases, this study established a three-dimensional numerical model using ABAQUS software (version 6.14-4) to systematically investigate the temporal evolution of groundwater drawdown and land subsidence during pit pumping, while quantifying the relationship between drawdown and subsidence stabilization time under different parameters. The key findings are as follows: (1) land subsidence stabilization time (50 days) is governed by external phreatic layer response, reaching 2.3 times longer than isolated aquifer conditions (22 days); (2) medium-permeability strata (0.01–10 K0,AdII) showed peak sensitivity to drawdown–subsidence coupling; (3) pumping from a confined aquifer extends the subsidence stabilization time by a factor of 1.1 compared to phreatic aquifer conditions. These findings provide valuable insights for the design and risk assessment of dewatering strategies in foundation pits within multi-aquifer systems.
To ensure the stability of deep foundation pits in confined aquifers, dewatering is often required. However, pumping from confined aquifers in large deep foundation pit groups may lead to significant environmental deformations. Therefore, field pumping and recharge tests are required to guide design of groundwater and environmental deformation control scheme. Focusing on a super-large deep foundation pit group in Shanghai, single-well pumping, multi-well pumping, and recharge tests were conducted in distinct geological zones (normally consolidated area and paleochannel zone). The hydraulic connectivity and spatiotemporal patterns of groundwater drawdown and soil settlement were systematically analyzed. The results show that: (1) There exists a certain hydraulic connection between the first and second confined aquifers. In the paleochannel area, the aquitard between the micro-confined and the first confined aquifer is insufficient to completely block hydraulic connectivity. (2) The ratio of ground surface settlement to groundwater drawdown is about 3.4 mm/m, and the deep soil settlement is significantly or even greater than the surface settlement, so it is necessary to strengthen the monitoring of deep settlement. (3) Recharge can elevate the groundwater and reduce settlement; however, it is difficult to eliminate the variation in settlement along the vertical direction.