Mathematical formulations of two-phase flows at an aerator remain a challenging issue for spillway design. Due to their complexities in terms of water–air interactions subjected to high flow velocities, experiments play an essential role in evaluations of numerical models. The paper focuses on the underlying influence of the air–water momentum exchange in the two-phase Two-Fluid Model. It is modified to better represent the drag force acting on a group of air bubbles and the wall lubrication force accounting for near-wall phase interactions. Based on data from a large aerator rig with an approach velocity of 14.3 m/s, the models are evaluated for calculations of entrained air characteristics of a flow mixture. The air bubble diameter used in the modeling ranges from 0.5 to 4 mm as suggested by the experiments. In terms of air cavity configurations and aerator air demand, smaller air bubbles lead to better agreement with the test results. As far as air concentrations are concerned, the modified model gains by comparison. In the air cavity zone, smaller bubble sizes also provide better matches with the experiments. However, the near-base air concentration remains overestimated downstream from the impact area. The fact that the program user must pre-define a single air bubble size in simulations presumably limits the correct reproduction of near-base air concentrations and of their decay.
1 December 2018 in Journal of Hydraulic Engineering
The paper deals with a unique spillway which incorporates an aerator in each flip bucket with the intention to aerate the flow and avoid subatmospheric air cavities enclosed by the jets. In terms of jet breakup and stability, the physical models and the prototype lead to contradicting conclusions. With sealed aerators, the models exhibit intact air cavities featuring negative air pressure, suggesting the aeration need. Computational fluid dynamics (CFD) is performed to determine the reason for the discrepancy. Both the prototype observations and CFD indicate that the jets break up as a result of air entrainment; the resulting cavity air-pressure drops are insignificantly small. The discrepancy is due to the small model scale, in which the threshold flow velocity for air entrainment is not met and the prerequisite for jet breakup does not exist. To correctly reproduce similar water–air flow phenomena, the model should be large enough to meet the air-entrainment criterion. When questioning a small-scale model with air-cavity formation, CFD simulations should be performed to check the model results and make corrections, if needed.
23 August 2016 in Modelling and Simulation in Engineering
The chute aerator of a spillway is a structure in such a sense that air is, in the intense emulsification, entrained into the high-velocity water flow. Correctly predicting the air entrainment and two-phase flow pattern at the aerator would contribute to reliable spillway operation. Based on experimental data, 2D numerical simulations are preformed to predict streamwise air concentrations in the aerated flow, in which a two-fluid model is used. Depending on the air bubble size, relatively good agreement is seen with the experiments in the air cavity zone. The simulations give rise to higher air concentration downstream of the cavity, which is presumably due to underestimation of the interfacial forces in the two-fluid model.
7 October 2015 in Journal of Applied Water Engineering and Research
An aerator is frequently used to prevent cavitation damages in high-velocity spillways. To understand its characteristics, one often resorts to physical model tests. To complement physical model tests, computation fluid dynamics simulations are used to determine water–air flow behaviors. With Bergeforsen's 35 m wide aerator, numerical modeling has been performed to evaluate its performance and improve its configuration. The parameters of interest include spillway discharge capacity, air entrainment rate, duct subpressure and air concentration in the aerated flow. The simulated discharge capacity agrees reasonably with experimental data. Due to the larger chute width, empirical formulas do not reasonably predict the air demand. To provide the air required by the aerator, its distribution in the cavity must be guaranteed. We thus looked into the air supply system and the air flux in the cavity to improve the aerator function. Larger vent openings in the middle of the chute are preferable for large-width aerators.
Most of the hydropower dams in Sweden were built before 1980. The present dam-safety guidelines have resulted in higher design floods than their spillway discharge capacity and the need for structural upgrades. This has led to renewed laboratory model tests. For some dams, even computational fluid dynamics (CFD) simulations are performed. This provides the possibility to compare the spillway discharge data between the model tests performed a few decades apart. The paper presents the hydropower development, the needs for the ongoing dam rehabilitations and the history of physical hydraulic modeling in Sweden. More than 20 spillways, both surface and bottom types, are analyzed to evaluate their discharge modeling accuracy. The past and present model tests are compared with each other and with the CFD results if available. Discrepancies do exist in the discharges between the model tests made a few decades apart. The differences fall within the range −8.3%–+11.2%. The reasons for the discrepancies are sought from several aspects. The primary source of the errors is seemingly the model construction quality and flow measurement method. The machine milling technique and 3D printing reduce the source of construction errors and improve the model quality. Results of the CFD simulations differ, at the maximum, by 3.8% from the physical tests. They are conducted without knowledge of the physical model results in advance. Following the best practice guidelines, CFD should generate results of decent accuracy for discharge prediction.
For safe spillway discharge of floods, attention is paid to the water flow. The resulting air flow inside the facility, an issue of personnel security, is sometimes disregarded. The spillway in question comprises two surface gates and two bottom outlet gates lying right below. Air passages to the outlet gates include an original gallery and a recently constructed vertical shaft. To understand water-air flow behavior, 3D CFD modelling is performed in combination with the physical model tests. The simulations are made with fully opened radial gates and at the full pool water level (FPWL). The results show that the operation of only the bottom outlets leads to an air supply amounting to ~57 m3/s, with the air flow rates 35 and 22 m3/s to the left and right outlets. The air supply to the right outlet comes from both the shaft and the gallery. The averaged air velocity in the shaft and the gallery are approximately 5 and 7 m/s. If only the surface gates are fully open, the water jet impinges upon the canal bottom, which encloses the air space leading to the bottom outlets; the air flow rate fluctuates about zero. If all the four gates are open, the total air demand is limited to ~10 m3/s, which is mainly attributable to the shear action of the meeting jets downstream. The air demand differs significantly among the flow cases. It is not the simultaneous discharge of all openings that results in the largest air demand. The flood release from only the two outlets is the most critical situation for the operation of the facility. The findings should provide reference for spillways with the same or similar layout.