UPPARI RAMAKRISHNA

Dr. UPPARI RAMAKRISHNA

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 February 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
PVPesaralanka Vyshnavi
Pesaralanka Vyshnavi
SCS.P. Challagulla
S.P. Challagulla
FVFelipe Vicencio
Felipe Vicencio
PBP. Suresh Chandra Babu
P. Suresh Chandra Babu
IHIsmail Hossain
Ismail Hossain
URUPPARI RAMAKRISHNA
UPPARI RAMAKRISHNA
Multi-story, reinforced-concrete (RC) building structures with soft stories are highly vulnerable to damage due to earthquake loads. The soft story causes a significant stiffness irregularity, which has led to numerous buildings collapsing in previous seismic events. In addition to the structural collapse, the failure of non-structural components (NSCs) has also been observed during past earthquakes. In light of this, this study investigates the effect of a soft story and its location on the seismic behavior of a supporting building and NSCs. The soft story is assumed to be located on the bottom (ground), middle, and top-story levels of the considered building models. Story displacements and inter-story drift ratios are evaluated to assess structural behavior. The floor response spectra and the amplification effects of NSC on the floor acceleration responses are studied to understand the behavior of NSCs. The analysis results revealed that the bottom soft story exhibits a considerable vertical stiffness irregularity, and its position substantially affects the floor response spectra. The amplification in the floor acceleration response was found to be greater at the soft-story level. This study reported that middle soft-story buildings exhibit the most remarkable amplification in the component’s acceleration. Finally, peak floor response demands are compared with the code-based formulation, and it is found that the code-based formulation’s linear assumption may lead peak floor response demands to be underestimated or overestimated.

3 April 2023 in Materials Today: Proceedings
Verified
Journal Article
Closed access
MGMounika Ganta
Mounika Ganta
URUPPARI RAMAKRISHNA
UPPARI RAMAKRISHNA
GRGillela Naresh Kumar Reddy
Gillela Naresh Kumar Reddy
KKKandula Suresh Kumar
Kandula Suresh Kumar

31 January 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SCS.P. Challagulla
S.P. Challagulla
Denise-Penelope N. KontoniDenise-Penelope N. Kontoni
Denise-Penelope N. Kontoni
ASASHOK KUMAR SULUGURU
ASHOK KUMAR SULUGURU
IHIsmail Hossain
Ismail Hossain
URUPPARI RAMAKRISHNA
UPPARI RAMAKRISHNA
JAJameel Mohammed Sardar Ali
Jameel Mohammed Sardar Ali
Nonstructural components (NSCs) are the systems that are attached to the floors of a building structure. NSCs have become critical in sustaining post-earthquake functionality while constructing seismic-resilient structures. The seismic behavior of the NSCs primarily depends upon the behavior of the structure to which the NSC is attached. Building structures are subjected to earthquake loads and behave differently when the supporting soil type varies. In light of this, this study investigates the seismic demands on NSC attached to the floors of an elastic-reinforced concrete building frame supported by different soil types. The present study considered a regular building frame and a building frame with mass irregularity on the lower story. A total of 3 sets of 11 horizontal spectral-matched ground motions consistent with each soil type are considered. Floor response spectra (FRS) can be used to measure the seismic load on non-structural components. Primarily, it was found that the ordinates of FRS depend on the floor height, the vibration periods of the building, and the soil type. The presence of mass irregularity at the lower story amplified the floor response at all floor levels. Additionally, the values of floor spectral acceleration increase as soil flexibility increases. The amplification factors are critical for generating the floor response spectra, and their variation along the building height is discussed. The floor acceleration was found to vary non-linearly with the height of the building. Finally, artificial neural networks (ANNs) are employed to develop the prediction models for dynamic amplification factors. The results calculated by the dynamic time history analyses are utilized to validate the proposed prediction models.

2 September 2020 in Journal of The Institution of Engineers (India): Series A
Verified
Journal Article
Closed access
PDF file
URUPPARI RAMAKRISHNA
UPPARI RAMAKRISHNA
MCMohan Sasalpur Chandrashekar
Mohan Sasalpur Chandrashekar

10 July 2019 in Advances in Intelligent Systems and Computing
Verified
Book Chapter
Closed access
PDF file
URUPPARI RAMAKRISHNA
UPPARI RAMAKRISHNA
SMS. C. Mohan
S. C. Mohan
KKK. Sai Pavan Kumar
K. Sai Pavan Kumar

1 September 2020 in International Journal of Engineering
Verified
Journal Article
Closed access
PDF file
URUPPARI RAMAKRISHNA
UPPARI RAMAKRISHNA
SMS. C. Mohan
S. C. Mohan
Increasing the population, urbanization has led to rapid construction of buildings. Due to space constraints and an increase in land cost, these buildings are built too close to each other and can cause damage under dynamic actions such as earthquakes. A new technique, known as structural coupling, has been developed recently, has found very effective in dissipating the dispersive vibrations. So far using coupling technique, adjacent dissimilar buildings are connected through a coupling device, such that it can reduce the dynamic response of the structure. The application of the structural coupling technique becomes challenging for similar buildings due to their in-phase behavior under dynamic loads. In the current research, the seismic performance of similar buildings with the coupling technique is experimentally tested on a shake table. A three storey model has been simulated using a unidirectional shake table with the scaled ground motion. Similar building construction uncertainties are accounted for in the study with slight variations in their dynamic properties. The connection devices used are bracings and passive viscoelastic dampers. The results obtained confirm the effectiveness of structural coupling technique with various configurations of dampers for similar buildings over seismic protection individual buildings.