Xiangyu Chen

Dr. Xiangyu Chen


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2025 in Processes
Verified
Journal Article
Open access
PDF file
THTianding Han
Tianding Han
QLQifei Li
Qifei Li
LSLin Shang
Lin Shang
XCXiangyu Chen
Xiangyu Chen
FZFeng Zhou
Feng Zhou
WLWangxu Li
Wangxu Li
Biomass clean energy is widely used as an alternative to fossil fuels due to its advantages of low carbon emissions, cleanliness, and renewability. Biomass fuel exchangers are important equipment for heat exchange between air and exhaust gasses after biomass combustion, and the air flow rate and structural characteristics of the exchanger have a significant impact on the heat transfer performance. In order to investigate the effect of Reynolds number on the heat transfer performance of the exchanger when air flows through, a serpentine tube heat exchange test bench was constructed, and numerical calculations were performed using the Realizable k-ε turbulence model for the entire channel. By changing the diameter and pitch of the serpentine tube, the effects of geometric parameters on the heat transfer performance were studied, and the flow characteristics of exhaust gasses and air inside the exchanger under various operating conditions were deduced. Subsequently, experimental validation was conducted by referring to the boundary conditions of numerical calculations, obtaining corresponding test data, and comparing the numerical and experimental results, showing that the errors in various physical quantities were within 5%. Through comprehensive analysis of the data, it was found that when the serpentine tube diameter is 80 mm and pitch is 300 mm, the Nusselt number (Nu) increased most significantly with Reynolds number (Re) by 25.17%, indicating the best heat transfer performance. Additionally, reducing tube diameter, increasing serpentine tube pitch, enlarging air-inlet flow velocity can enhance Re, increase fluid disturbance, and improve convective heat transfer intensity, thereby increasing Nu and strengthening the heat transfer performance of the serpentine tube exchanger.

3 July 2025 in Energies
Verified
Journal Article
Open access
PDF file
HTHongqiang Tang
Hongqiang Tang
QLQifei Li
Qifei Li
XCXiangyu Chen
Xiangyu Chen
ZLZhanyong Li
Zhanyong Li
SLShiwei Li
Shiwei Li
The transient operation of pump turbines generates significant flow-induced instabilities, prompting a comprehensive numerical investigation using the SST k−ω turbulence model to examine these instability effects throughout the complete operating range in turbine mode. This study specifically analyzes the evolutionary mechanisms of unsteady flow dynamics under ten characteristic off-design conditions while simultaneously characterizing the pressure fluctuation behavior within the vaneless space (VS). The results demonstrate that under both low-speed conditions and near-zero-discharge conditions, the VS and its adjacent flow domains exhibit pronounced flow instabilities with highly turbulent flow structures, while the pressure fluctuation amplitudes remain relatively small due to insufficient rotational speed or flow rate. Across the entire turbine operating range, the blade passing frequency (BPF) dominates the VS pressure fluctuation spectrum. Significant variations are observed in both low-frequency components (LFCs) and high-frequency, low-amplitude components (HF-LACs) with changing operating conditions. The HF-LACs exhibit relatively stable amplitudes but demonstrate significant variation in the frequency spectrum distribution across different operating conditions, with notably broader frequency dispersion under runaway conditions and adjacent operating points. The LFCs demonstrate significantly higher spectral density and amplitude magnitudes under high-speed, low-discharge operating conditions while exhibiting markedly reduced occurrence and diminished amplitudes in the low-speed, high-flow regime. This systematic investigation provides fundamental insights into the flow physics governing pump-turbine performance under off-design conditions while offering practical implications for optimizing transient operational control methodologies in hydroelectric energy storage systems.

30 December 2024 in Energies
Verified
Journal Article
Open access
PDF file
THTianding Han
Tianding Han
QLQifei Li
Qifei Li
LFLicheng Feng
Licheng Feng
XCXiangyu Chen
Xiangyu Chen
FZFeng Zhou
Feng Zhou
ZLzhenggui Li
zhenggui Li
During pump operation, the pump-turbine system experiences unstable fluctuations in outlet pressure, which induces turbulence and additional energy losses. Understanding the impact of outlet pressure variations on the internal flow field is crucial for the further development of turbine units. This study employs numerical methods to systematically analyze the effects of outlet pressure changes on flow characteristics and energy loss. The results show that a decrease in outlet pressure to P0.9BEP significantly increases entropy production in the double-row stay guide vane region, primarily due to flow separation and vortex formation. In the flow passage, sealing gap, and tailpipe regions, entropy production is mainly driven by wall effects, while secondary flows influence the spiral case. The vortex distribution in the double-row stay guide vane is complex, with different variation trends observed in the active and fixed guide vane regions. Outlet pressure changes affect the interaction between the flow passage blades and the fluid, leading to localized flow separation and directly impacting energy loss in downstream components. Additionally, the rate of change in outlet pressure significantly influences vortex generation and dissipation. This research provides new theoretical insights and research directions for performance optimization and energy loss control in pump-turbine systems.

12 July 2025 in Processes
Verified
Journal Article
Open access
PDF file
FZFeng Zhou
Feng Zhou
QLQifei Li
Qifei Li
LXLu Xin
Lu Xin
XCXiangyu Chen
Xiangyu Chen
SZShiang Zhang
Shiang Zhang
YQYuqian Qiao
Yuqian Qiao
As a core component in renewable energy systems for grid regulation, hydropower units are increasingly exposed to flow conditions that elevate the risk of cavitation and erosion, posing significant challenges to the safe operation of flow-passage components. In this study, model testing and computational fluid dynamics (CFD) simulations are employed to investigate the hydraulic performance and cavitation behavior of a bulb turbine operating under rated head conditions and varying cavitation numbers. The analysis focuses on how changes in cavitation intensity affect flow characteristics and efficiency within the runner region. The results show that as the cavitation number approaches its critical value, the generation, growth, and collapse of vapor cavities increasingly disturb the main flow, causing a marked drop in blade hydraulic performance and overall turbine efficiency. Cavitation predominantly occurs on the blade’s suction side near the trailing edge rim and in the clearance zone near the hub, with bubble coverage expanding as the cavitation number decreases. A periodic inverse correlation between surface pressure and the cavitation area is observed, reflecting the strongly unsteady nature of cavitating flows. Furthermore, lower cavitation numbers lead to intensified pressure pulsations, aggravating flow unsteadiness and raising the risk of vibration.

16 May 2025 in Energies
Verified
Journal Article
Open access
PDF file
XCXiangyu Chen
Xiangyu Chen
QLQifei Li
Qifei Li
LXLu Xin
Lu Xin
SZShiang Zhang
Shiang Zhang
MCMingjie Cheng
Mingjie Cheng
THTianding Han
Tianding Han
Under extremely low-head conditions, the performance and stability of pump-turbine units are strongly influenced by the flow distortion caused by variations in guide vane opening. In this study, a pump-turbine model—representative of a domestic pumped storage power station—was investigated through a combination of experimental observations and three-dimensional unsteady numerical simulations employing the SST k-ω turbulence model. The analysis focused on characterizing the variations in turbulence kinetic energy, pressure pulsations, and impeller force fluctuations as the guide vane opening was altered. The results reveal that, with increasing guide vane opening, the turbulence kinetic energy within the impeller region is notably reduced. This reduction is primarily attributed to a decrease in energy losses along the suction surfaces of the blades and within the straight pipe section of the tailwater tunnel. Simultaneously, pressure pulsations were detected at multiple locations including the volute inlet, the blade-free zone, downstream of the conical pipe, and along the inner surface of the shaft tube. While most regions experienced a decline in pressure pulsation intensity with larger openings, the bladeless zone exhibited a significant increase. Moreover, force analysis at four distinct guide vane settings indicated that an opening of 41 mm resulted in relatively uniform fluctuations in the impeller forces. This uniformity suggests that an optimal guide vane configuration exists, which minimizes uneven stress distributions and enhances the operational stability of the pump-turbine under extremely low-head conditions. These findings offer valuable insights for the design and operational optimization of pump-turbine systems in pumped storage power stations.

20 August 2026 in Processes
Verified
Journal Article
Open access
PDF file
LLLing Li
Ling Li
QLQifei Li
Qifei Li
XCXiangyu Chen
Xiangyu Chen
To elucidate the coupling characteristics between unsteady flow and hydrodynamic loads in the guide vane region of a pump–turbine under runaway conditions, a model pump–turbine of a high-head pumped storage power station was selected as the research object. A combined approach of model experiments and three-dimensional unsteady numerical simulations was employed to investigate the guide vane hydraulic torque, flow field structures, pressure distribution, and pressure fluctuation characteristics under different pre-opening guide vane conditions. In the experiments, the hydraulic torque of guide vanes was measured using a guide vane shaft strain testing method at five guide vane openings of 19 mm, 25 mm, 33 mm, 41 mm, and 45 mm. In the numerical simulations, a full-passage unsteady computational model was established based on the SST k-ω turbulence model, and the reliability of the numerical model was validated against experimental results. The results indicate that the guide vane hydraulic torque under runaway conditions exhibits pronounced periodic fluctuations, and the dominant period in the time domain is consistent with the blade passing frequency, demonstrating that rotor–stator interaction between the runner wake and guide vanes is the primary mechanism inducing unsteady hydraulic loads. As the guide vane opening decreases, the flow passage area in the guide vane region is reduced, and the high-speed swirling flow at the runner outlet generates significant jet impingement and local shear layers near the guide vane inlet, resulting in enhanced circumferential non-uniformity of the flow field and a substantial increase in the pressure difference across the guide vane surfaces. Among all operating conditions, the hydraulic torque fluctuation at a0 = 19 mm is the most severe. Under small-opening conditions, flow separation, wake accumulation, and local backflow structures are prone to occur in the vicinity of the guide vanes, accompanied by pronounced high-frequency pressure disturbances and local impulsive pressure peaks. With increasing guide vane opening, the flow attachment behavior and flow field continuity are gradually improved, and the pressure fluctuations evolve from random oscillations to regular periodic pulsations, indicating a significant enhancement in flow stability. The study demonstrates that small guide vane opening conditions produce hydrodynamic load characteristics—specifically, higher-amplitude and more intermittent torque fluctuations, as well as lower minimum pressures—that are indicative of conditions conducive to increased vibration, fatigue accumulation, and cavitation risk; however, direct structural or two-phase cavitation analyses are required to confirm these implications. The present results can provide a theoretical basis for the optimal design of guide vane mechanisms and the safe operation of pump–turbines under runaway conditions, and quantitative coupling analysis reveals that the cross-correlation between inlet pressure and torque decreases from R = 0.87 at a0 = 19 mm to R = 0.72 at a0 = 45 mm, confirming that the flow–load coupling weakens substantially with increasing opening.