A large number of studies have examined the origins of high-catalytic activities of nanoparticles, but very few have discussed the lifetime of high-energy electrons in nanoparticles. The lifetime is one of the factors determining electron transfer and thus catalytic activity. Much of the lifetime of electrons reported in the literature is too short for a high transfer-efficiency of photo-excited electrons from a catalyst to the attached molecules. We observed TiO2 nanoparticles using the femtosecond laser two-color pump-probe technique with photoemission electron microscopy having a 40 nm spatial resolution. A lifetime longer than 4 ps was observed together with a fast decay component of 100 fs time constant when excited by a 760 nm laser. The slow decay component was observed only when the electrons in an intermediate state pumped by the fundamental laser pulse were excited by the second harmonic pulse. The electronic structure for the asymmetry of the pump-probe signal and the origin of the two decay components are discussed based on the color center model of the oxygen vacancy.
Extracting defect profile parameters from measured defect images poses a significant challenge in extreme ultraviolet (EUV) multilayer defect metrologies, because these parameters are crucial for assessing defect printing behavior and determining appropriate repair strategies. This paper proposes to reconstruct defect profile parameters from reflected field intensity images of a phase defect assisted by transfer learning with fine-tuning. These images are generated through simulations using the rigorous finite-difference time-domain (FDTD) method. The VGG-16 pre-trained model, known for its robust feature extraction capability, is adopted and fine-tuned to map the intensity images to the defect profile parameters. The results demonstrate that the proposed approach accurately reconstructs multilayer defect profile parameters, thus providing important information for mask repair strategies.
22 June 2026 in Japanese Journal of Applied Physics
Phase-defect inspection is crucial in EUV (Extreme ultraviolet) lithography for achieving high semiconductor-chip yields. While at-wavelength inspection can detect phase defects, inspecting entire masks in a practical timeframe was once a showstopper. This challenge was solved by using a pixel size of 500 nanometers or larger to detect defects tens of nanometers in size. The focus then shifted to reducing the background signal, Rpix, from large pixels. Rpix is greatly reduced in the dark-field configuration and controlling the angular distribution of roughness-induced scattering is essential for defect detection. This paper reports a detailed analysis of the power spectral density (PSD) of surface-roughness-induced scattering using a developed rigorous numerical code. The study concludes that coherence strongly affects PSD, thereby controlling the detectability of phase defects and that the illumination coherence length and the blocking inner numerical aperture NAd are the decisive parameters in the phase-defect inspection.