Tong Wu

Dr. Tong Wu

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2025 in Applied Sciences
Verified
Journal Article
Open access
LWLu Wu
Lu Wu
LZLiwen Zhu
Liwen Zhu
TWTong Wu
Tong Wu
CZChengliang Zhang
Chengliang Zhang
ASAnyu Sun
Anyu Sun
BJBingfeng Ju
Bingfeng Ju
Fluororubber sealing products are widely used in nuclear power equipment, and the degree of degradation of their mechanical properties directly affects the sealing performance, which in turn affects the overall safety of nuclear power units. In order to quantitatively evaluate the degradation of the mechanical properties of fluororubber, the theory of ultrasonic propagation in fluororubber was studied. A second-order generalized Maxwell viscoelastic model was constructed in a small strain scenario of high-frequency harmonic vibration to describe the correlation between the mechanical properties and acoustic parameters. A nondestructive evaluation method for mechanical performance degradation using ultrasonic waves based on the nonlinear fitting of the model parameters was proposed. A control experiment was designed using O-rings that had been in service and those that had not yet been used in nuclear power, and mechanical tensile tests and electron microscopy microscopic analyses were conducted. The results showed that the overall elastic modulus of the used sealing ring (2.97 ± 0.15 GPa) was significantly higher than that of the unused sealing ring (2.75 ± 0.22 GPa), consistent with the results of the mechanical tensile tests. However, the sound attenuation coefficient of the unused sealing ring was significantly higher than that of the used sealing ring. Therefore, the ultrasonic evaluation of the mechanical performance degradation of fluororubber based on the viscoelastic model is a nondestructive testing method with engineering application potential.

31 July 2025 in Journal of Real-Time Image Processing
Verified
Journal Article
Closed access
PDF file
XDXingguang Duan
Xingguang Duan
ZZZhongyue Zhang
Zhongyue Zhang
TWTong Wu
Tong Wu
CLChangsheng Li
Changsheng Li
JHJiaLe Huan
JiaLe Huan
TCTengfei Cui
Tengfei Cui

3 November 2025 in Optics
Verified
Journal Article
Open access
PDF file
TWTong Wu
Tong Wu
HLHaopeng Li
Haopeng Li
CZChuan Zhang
Chuan Zhang
JYJingwei Yu
Jingwei Yu
JLJianjun Liu
Jianjun Liu
BJBingfeng Ju
Bingfeng Ju
With the increasing application of oxide films in nuclear fuel assemblies, the accurate measurement of thin-film thickness has become increasingly critical. Traditional spectral interferometry techniques have limitations when dealing with new materials and complex structures; therefore, this study proposes a multi-channel wide-spectrum high-resolution analysis technique. This technique optimizes the utilization of photosensitive elements through multi-channel spectral sampling, combined with precision spectroscopic components and an independent optical focusing and imaging system. Simultaneously, it adopts optical correction technologies such as coma optimization and astigmatism correction to improve imaging quality and spectral resolution. Additionally, it enhances data accuracy by means of multi-channel calibration based on the least squares method and non-linear correction. The technique enables high-precision measurement ranging from the nanometer to the millimeter scale, resulting in a significantly wider measurement range compared to traditional spectrometers. Simulation verification shows that this technique outperforms existing technologies in information acquisition, analysis accuracy, and detection efficiency, and has broad application prospects in fields such as semiconductor chip manufacturing and optical coating. In the future, focus will be placed on expanding the spectral range, improving resolution, and enhancing real-time measurement capabilities.


15 May 2026 in Metrology
Verified
Journal Article
Open access
PDF file
TWTong Wu
Tong Wu
HLHaopeng Li
Haopeng Li
CLChenxu Liu
Chenxu Liu
CZChuan Zhang
Chuan Zhang
JWJiahao Wu
Jiahao Wu
BJBingfeng Ju
Bingfeng Ju
In the context of the increasing demands of precision manufacturing and nanotechnology, especially for emerging fields such as Oxide oxide films in Nuclear nuclear fuel assemblies, the measurement of multi-layer inhomogeneous thin films faces significant challenges. Traditional spectroscopic interference thickness measurement techniques have limitations in handling dispersion interference, parameter coupling, and the efficient solution of nonlinear inverse problems. This study proposes a new model that integrates deep learning and physical model fitting. It constructs a theoretical model of multi-layer thin-film interference spectroscopy based on the Lorentz–Drude formula, uses a generative adversarial network (GAN) for initial structure analysis, and builds a two-layer optimization framework of “deep learning rough positioning—physical model fine fitting”. The research aims to break through the limitations of traditional methods, improve measurement accuracy and anti-noise ability, and provide a key technical support for emerging fields.

8 March 2025
Verified
Book Chapter
Closed access
PDF file
TWTong Wu
Tong Wu
DWDeying Wang
Deying Wang
FCFengjuan Chen
Fengjuan Chen
KLKefu Lv
Kefu Lv
JWJin Wang
Jin Wang
ZMZhifeng Mi
Zhifeng Mi