Sahar Karimian

Ms. Sahar Karimian

Atlantic Technological University, Sligo, Ireland
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 May 2025 in Biosensors
Verified
Journal Article
Open access
PDF file
Sahar KarimianSahar Karimian
Sahar Karimian
Muhammad Mahmood AliMuhammad Mahmood Ali
Muhammad Mahmood Ali
Marion McAfeeMarion McAfee
Marion McAfee
WSWaqas Saleem
Waqas Saleem
DDDinesh Babu Duraibabu
Dinesh Babu Duraibabu
Elfed LewisElfed Lewis
Elfed Lewis
Fibre optic sensors (FOSs) have developed as a transformative technology in healthcare, often offering unparalleled accuracy and sensitivity in monitoring various physiological and biochemical parameters. Their applications range from tracking vital signs to guiding minimally invasive surgeries, enabling advancements in medical diagnostics and treatment. However, the integration of FOSs into biomedical applications faces numerous challenges. This article describes some challenges for adopting FOSs for biomedical purposes, exploring technical and practical obstacles, and examining innovative solutions. Significant challenges include biocompatibility, miniaturization, addressing signal processing complexities, and meeting regulatory standards. By outlining solutions to the stated challenges, it is intended that this article provides a better understanding of FOS technologies in biomedical settings and their implementation. A broader appreciation of the technology, offered in this article, enhances patient care and improved medical outcomes.

7 December 2022 in European Journal of Ophthalmology
Verified
Journal Article
Closed access
CMCameron McLintock
Cameron McLintock
HNHamed Niyazmand
Hamed Niyazmand
SSShiney Seo
Shiney Seo
GBGraham Barrett
Graham Barrett
VNVinay Kumar Nilagiri
Vinay Kumar Nilagiri
JMJames McKelvie
James McKelvie
Purpose: To evaluate the agreement between two biometry devices, the Heidelberg Anterion and the Galilei G6 Lens Professional. Methods: Eyes were scanned with both biometry devices. Analysis of inter-device agreement was conducted for the following metrics: flat (K1), steep (K2) and mean K (Km) for anterior, posterior and total cornea, lens thickness (LT), central corneal thickness (CCT), anterior chamber depth (ACD), white to white (WTW) and axial length (AL). Generalised Estimating Equations were used to account for inter-eye correlation. Bland-Altman analysis was conducted to derive the mean difference (MD) and limits of agreement (LoA) between devices. Differences were deemed clinically significant if they would result in a change in post-operative refraction of 0.25D or more. Results: 159 eyes of 91 patients were included. For the anterior cornea, no significant MD was found for K1 (−0.11D) and K2 (−0.10D), although a significant MD was found for Km (−0.10D). For posterior cornea, while there were no significant MDs between devices, the LoAs were wide for both posterior K1(−0.70, 0.68) and posterior K2 (−1.01, 1.29). For total corneal power, significant MDs were found in K1 (0.36D), and Km (0.26D) but not for K2 (0.17D). Significant MDs were found for LT (0.179mm), CCT (−0.005mm), ACD (−0.111mm) and WTW (−0.158mm), but not for AL (−0.021mm, p > 0.05). Conclusion: There are statistically but not clinically significant differences between Anterion and Galilei G6 Lens Professional in anterior Km, LT, CCT, ACD and WTW. Measurements of the posterior and total cornea are not interchangeable between devices.

4 April 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
Sahar KarimianSahar Karimian
Sahar Karimian
Muhammad Mahmood AliMuhammad Mahmood Ali
Muhammad Mahmood Ali
Marion McAfeeMarion McAfee
Marion McAfee
WSWaqas Saleem
Waqas Saleem
RWRuoning Wang
Ruoning Wang
Elfed LewisElfed Lewis
Elfed Lewis
Fiber optic sensors (FOSs) have developed as a transformative technology in healthcare, often offering unparalleled accuracy and sensitivity in monitoring various physiological and biochemical parameters. Their applications range from tracking vital signs to guiding minimally invasive surgeries, enabling advancements in medical diagnostics and treatment. However, the integration of FOSs into biomedical applications faces numerous challenges. This article describes some of the challenges for adopting FOSs for biomedical purposes, exploring technical and practical obstacles, and examining innovative solutions. Major challenges include biocompatibility, miniaturization and addressing signal processing complexities as well as meeting regulatory standards. Through outlining solutions to the stated challenges, it is intended that this article will therefore provide a better understanding of FOSs technology in biomedical settings and their implementation. A wider appreciation of the technology provided in this article will ultimately lead to enhancing patient care and improved medical outcomes.