Piotr Falkowski

Piotr Falkowski

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 September 2017 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
PFPiotr Falkowski
Piotr Falkowski
ASAndrzej Sikorski
Andrzej Sikorski
This paper presents two new implementations of finite control set model predictive control (FCS-MPC) methods applied to ac-dc converters with an inductive.capacitive.inductive (LCL) filter. The LCL filter, despite its advantages, can cause a strong resonance in the grid current and also pose a substantially more complex control problem. The new solutions improve the FCS-MPC with an active damping algorithm by eliminating low-order grid current harmonics and decreasing sensitivity to grid voltage distortion. The new methods, i.e., PCi1i2uc and PCi1i2uc-2steps propose multivariable approaches using converter-side current, line-side current, and capacitor voltage. Another improvement involves extending the prediction horizon in PCi1 i2uc-2steps. Both methods have been tested and compared in steady and transient states as well as under grid voltage disturbances. The methods were also compared with a predictive control algorithm with active damping. The simulation results and experimental measurements validate the developed control schemes and show high quality of grid current (low THDi value), high dynamic performance, and immunity under distorted grid voltage conditions.

19 March 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
PFPiotr Falkowski
Piotr Falkowski
ASAndrzej Sikorski
Andrzej Sikorski
MMMariusz Malinowski
Mariusz Malinowski
This paper presents a new algorithm of finite control set model predictive control (FCS-MPC) with floating virtual voltage vectors (VVs) applied to grid-connected voltage source converter. The new solution improves the conventional FCS-MPC and FCS-MPC with virtual VVs, assuring a fixed switching frequency. In comparison with FCS-MPC using virtual VVs, the proposed algorithm ensures a shorter distance between floating virtual VVs and actual voltage vector achieves lower THDi and ripples of the grid current for the same sampling time. The proposed control method has been experimentally validated using a 5 kW prototype. The algorithm was examined and compared in steady and transient states as well as under grid voltage disturbances, such as higher harmonics, dips, unbalance. The simulation results and experimental measurements confirm that the developed control technique shows a high quality of the grid current (low THDi value), high dynamic performance and immunity in case of weak grid conditions.

1 May 2016
Verified
Conference Paper
Closed access
PFPiotr Falkowski
Piotr Falkowski
ASAndrzej Sikorski
Andrzej Sikorski
The article presents Finite Control Set Model Predictive Control for an AC/DC converter with a LCL filter. The extended cost function J is responsible for the adjustment of controlled values. An important issue raised in the article is the impact of dead time on the prediction of controlled values. The negative impact of dead time results in an increased THD of the grid current. The article proposes an algorithm correcting the impact of dead time which was confirmed by the results of Matlab-Simulink simulations and laboratory tests.


13 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
ASAndrzej Sikorski
Andrzej Sikorski
PFPiotr Falkowski
Piotr Falkowski
MKMarek Tomasz Korzeniewski
Marek Tomasz Korzeniewski
The article presents comprehensive results of research on two representative topologies of converters used in the path of processing energy generated in a wind turbine and transmitted to the grid. The topology T1 uses a two-level transistor-controlled rectifier as a converter from the generator side, while the T2 topology uses DC/DC boost converter. In both topologies, a three-level back-to-back converter with a line filter L was used as a grid converter. The conclusions indicate the tendency of changes in power losses depending on the aforementioned parameters and can be used at the stage of deciding on the choice of topology, operating parameters or selection of control methods depending on the specific operating conditions of the wind turbine.

1 October 2017 in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
Verified
Journal Article
Open access
PDF file
PFPiotr Falkowski
Piotr Falkowski
KKK. Kulikowski
K. Kulikowski
RGR. Grodzki
R. Grodzki
Power electronic three-level AC-DC converters connecting a utility grid with DC supplies are widely used in renewable energy sources. For such distributed systems, the quality of energy is very important. Hence, control algorithms of an AC-DC converter have to provide not only a sinusoidal shape of grid current, but also stable operation during transient states in the grid, e.g. voltage dips or voltage unbalance. This paper deals with the problem of robustness of AC-DC control methods under disturbed grid voltage. Three modern predictive control algorithms are presented and investigated under grid voltage distortions. Experimental results from a laboratory test setup illustrating properties of the described methods are shown.