Du-Hyeong Lee

Prof. Du-Hyeong Lee

Department of Prosthodontics, School of Dentistry, Kyungpook National University, Daegu, Korea
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2017 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
Hang Nga MaiHang Nga Mai
Hang Nga Mai
KLKyu-Bok Lee
Kyu-Bok Lee
DLDu-Hyeong Lee
Du-Hyeong Lee

1 January 2017 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
WLWan-Sun Lee
Wan-Sun Lee
DLDu-Hyeong Lee
Du-Hyeong Lee
Kyu-Bok LeeKyu-Bok Lee
Kyu-Bok Lee
Lee WS, et al. J Adv Prosthodont. 2017 Aug;9(4):265-270. https://doi.org/10.4047/jap.2017.9.4.265

4 January 2023 in Journal of Medical Internet Research
Verified
Journal Article
Open access
Hang Nga MaiHang Nga Mai
Hang Nga Mai
VDVan Viet Dam
Van Viet Dam
DLDu-Hyeong Lee
Du-Hyeong Lee
Background: The novel concept of immersive 3D augmented reality (AR) surgical navigation has recently been introduced in the medical field. This method allows surgeons to directly focus on the surgical objective without having to look at a separate monitor. In the dental field, the recently developed AR-assisted dental implant navigation system (AR navigation), which uses innovative image technology to directly visualize and track a presurgical plan over an actual surgical site, has attracted great interest. Objective: This study is the first systematic review and meta-analysis study that aimed to assess the accuracy of dental implants placed by AR navigation and compare it with that of the widely used implant placement methods, including the freehand method (FH), template-based static guidance (TG), and conventional navigation (CN). Methods: Individual search strategies were used in PubMed (MEDLINE), Scopus, ScienceDirect, Cochrane Library, and Google Scholar to search for articles published until March 21, 2022. This study was performed in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines and registered in the International Prospective Register of Systematic Reviews (PROSPERO) database. Peer-reviewed journal articles evaluating the positional deviations of dental implants placed using AR-assisted implant navigation systems were included. Cohen d statistical power analysis was used to investigate the effect size estimate and CIs of standardized mean differences (SMDs) between data sets. Results: Among the 425 articles retrieved, 15 articles were considered eligible for narrative review, 8 articles were considered for single-arm meta-analysis, and 4 were included in a 2-arm meta-analysis. The mean lateral, global, depth, and angular deviations of the dental implant placed using AR navigation were 0.90 (95% CI 0.78-1.02) mm, 1.18 (95% CI 0.95-1.41) mm, 0.78 (95% CI 0.48-1.08) mm, and 3.96° (95% CI 3.45°-4.48°), respectively. The accuracy of AR navigation was significantly higher than that of the FH method (SMD=−1.01; 95% CI −1.47 to −0.55; P<.001) and CN method (SMD=−0.46; 95% CI −0.64 to −0.29; P<.001). However, the accuracies of the AR navigation and TG methods were similar (SMD=0.06; 95% CI −0.62 to 0.74; P=.73). Conclusions: The positional deviations of AR-navigated implant placements were within the safety zone, suggesting clinically acceptable accuracy of the AR navigation method. Moreover, the accuracy of AR implant navigation was comparable with that of the highly recommended dental implant–guided surgery method, TG, and superior to that of the conventional FH and CN methods. This review highlights the possibility of using AR navigation as an effective and accurate immersive surgical guide for dental implant placement.

23 October 2020 in Journal of Medical Internet Research
Verified
Journal Article
Open access
Hang Nga MaiHang Nga Mai
Hang Nga Mai
DLDu-Hyeong Lee
Du-Hyeong Lee
Background: The accurate assessment and acquisition of facial anatomical information significantly contributes to enhancing the reliability of treatments in dental and medical fields, and has applications in fields such as craniomaxillofacial surgery, orthodontics, prosthodontics, orthopedics, and forensic medicine. Mobile device–compatible 3D facial scanners have been reported to be an effective tool for clinical use, but the accuracy of digital facial impressions obtained with the scanners has not been explored. Objective: We aimed to review comparisons of the accuracy of mobile device–compatible face scanners for facial digitization with that of systems for professional 3D facial scanning. Methods: Individual search strategies were employed in PubMed (MEDLINE), Scopus, Science Direct, and Cochrane Library databases to search for articles published up to May 27, 2020. Peer-reviewed journal articles evaluating the accuracy of 3D facial models generated by mobile device–compatible face scanners were included. Cohen d effect size estimates and confidence intervals of standardized mean difference (SMD) data sets were used for meta-analysis. Results: By automatic database searching, 3942 articles were identified, of which 11 articles were considered eligible for narrative review, with 6 studies included in the meta-analysis. Overall, the accuracy of face models obtained using mobile device–compatible face scanners was significantly lower than that of face models obtained using professional 3D facial scanners (SMD 3.96 mm, 95% CI 2.81-5.10 mm; z=6.78; P<.001). The difference between face scanning when performed on inanimate facial models was significantly higher (SMD 10.53 mm, 95% CI 6.29-14.77 mm) than that when performed on living participants (SMD 2.58 mm, 95% CI 1.70-3.47 mm, P<.001, df=12.94). Conclusions: Overall, mobile device–compatible face scanners did not perform as well as professional scanning systems in 3D facial acquisition, but the deviations were within the clinically acceptable range of <1.5 mm. Significant differences between results when 3D facial scans were performed on inanimate facial objects and when performed on the faces of living participants were found; thus, caution should be exercised when interpreting results from studies conducted on inanimate objects.

1 January 2022 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
HMHai Yen Mai
Hai Yen Mai
Hang Nga MaiHang Nga Mai
Hang Nga Mai
CLCheong-Hee Lee
Cheong-Hee Lee
Kyu-Bok LeeKyu-Bok Lee
Kyu-Bok Lee
So-Yeun KimSo-Yeun Kim
So-Yeun Kim
DLDu-Hyeong Lee
Du-Hyeong Lee
Mai HY, et al. J Adv Prosthodont. 2022 Apr;14(2):88-95. https://doi.org/10.4047/jap.2022.14.2.88

Hang Nga MaiHang Nga Mai
Hang Nga Mai
JKJaeil Kim
Jaeil Kim
Youn-Hee ChoiYoun-Hee Choi
Youn-Hee Choi
DLDu-Hyeong Lee
Du-Hyeong Lee
The use of three-dimensional face-scanning systems to obtain facial models is of increasing interest, however, systematic assessments of the reliability of portable face-scan devices have not been widely conducted. Therefore, a systematic review and meta-analysis were performed considering the accuracy of facial models obtained by portable face-scanners in comparison with that of those obtained by stationary face-scanning systems. A systematic literature search was conducted in electronic databases following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines for articles published from 1 January 2009 to 18 March 2020. A total of 2806 articles were identified, with 21 articles available for the narrative review and nine studies available for meta-analysis. The meta-analysis revealed that the accuracy of the digital face models generated by the portable scanners was not significantly different from that of the stationary face-scanning systems (standard mean difference (95% confidence interval) = −0.325 mm (−1.186 to 0.536); z = −0.74; p = 0.459). Within the comparison of the portable systems, no statistically significant difference was found concerning the accuracy of the facial models among scanning methods (p = 0.063). Overall, portable face-scan devices can be considered reliable for obtaining facial models. However, caution is needed when applying face-scanners with respect to scanning device settings, control of involuntary facial movements, landmark and facial region identifications, and scanning protocols.