So-Yeun Kim

Prof. Dr. So-Yeun Kim

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
HMHai Yen Mai
Hai Yen Mai
Hang Nga MaiHang Nga Mai
Hang Nga Mai
CLCheong-Hee Lee
Cheong-Hee Lee
Kyu-Bok LeeKyu-Bok Lee
Kyu-Bok Lee
So-Yeun KimSo-Yeun Kim
So-Yeun Kim
DLDu-Hyeong Lee
Du-Hyeong Lee
Mai HY, et al. J Adv Prosthodont. 2022 Apr;14(2):88-95. https://doi.org/10.4047/jap.2022.14.2.88

1 January 2025 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
TWThaw Thaw Win
Thaw Thaw Win
Hang Nga MaiHang Nga Mai
Hang Nga Mai
So-Yeun KimSo-Yeun Kim
So-Yeun Kim
SCSeok-Hwan Cho
Seok-Hwan Cho
JKJong-Eun Kim
Jong-Eun Kim
DLDu-Hyeong Lee
Du-Hyeong Lee
Win TT, et al. J Adv Prosthodont. 2025 Aug;17(4):224-234. https://doi.org/10.4047/jap.2025.17.4.224

25 August 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
HLHakjun Lee
Hakjun Lee
KeunBaDa SonKeunBaDa Son
KeunBaDa Son
DLDu-Hyeong Lee
Du-Hyeong Lee
So-Yeun KimSo-Yeun Kim
So-Yeun Kim
Kyu-Bok LeeKyu-Bok Lee
Kyu-Bok Lee
The aim of this study is to evaluate the wear volume of interim crowns fabricated using digital light processing 3D printing according to the printing angle. A total of five patients undergoing the placement of a single crown on the mandibular molar were included. Interim crowns were fabricated directly in the oral cavity using the conventional method. A digital light processing 3D printer was then used to fabricate crowns with build angles of 0, 45, and 90 degrees. Therefore, four fabricated interim crowns were randomly delivered to the patients, and each was used for one week. Before and after use, the intaglio surfaces of the interim crowns were scanned using a 3D scanner. The volume changes before and after use were measured, and changes in the height of the occlusal surface were evaluated using the root mean square value. Data normality was verified by statistical analysis, and the wear volume in each group was evaluated using a one-way analysis of variance and Tukey’s honestly significant difference test (α = 0.05). Compared with the RMS values of the conventional method (11.88 ± 2.69 µm) and the 3D-printing method at 0 degrees (12.14 ± 2.38 µm), the RMS values were significantly high at 90 degrees (16.46 ± 2.39 µm) (p < 0.05). Likewise, there was a significant difference in the change in volume between the groups (p = 0.002), with a significantly higher volume change value at 90 degrees (1.74 ± 0.41 mm3) than in the conventional method (0.70 ± 0.15 mm3) (p < 0.05). A printing angle of 90 degrees is not recommended when interim crowns are fabricated using digital light processing 3D printing.

1 January 2024 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
So-Yeun KimSo-Yeun Kim
So-Yeun Kim
YCYoung Eun Cho
Young Eun Cho
SHSeoung-Jin Hong
Seoung-Jin Hong
JHJung-Bo Huh
Jung-Bo Huh
SPSe-wook Pyo
Se-wook Pyo
SYSoo-Yoen Yoo
Soo-Yoen Yoo
Kim SY, et al. J Adv Prosthodont. 2024 Aug;16(4):255-266. https://doi.org/10.4047/jap.2024.16.4.255

13 June 2021 in Materials
Verified
Journal Article
Open access
PDF file
WCWon-Tak Cho
Won-Tak Cho
So-Yeun KimSo-Yeun Kim
So-Yeun Kim
SJSung-In Jung
Sung-In Jung
SKSeong Soo Kang
Seong Soo Kang
SKSe Eun Kim
Se Eun Kim
JHJung-Bo Huh
Jung-Bo Huh
This study aimed to compare two methods of crosslinking collagen type I on implanted titanium surfaces, that is, using glutaraldehyde (GA) or gamma-rays (GRs), in a beagle dog model. For in vivo experiments, implants were allocated to three groups and applied to mandibular bone defects in beagle dogs; Group SLA; non-treated Sandblasted, large grit, acid-etched (SLA) implants, Group GA; SLA implants coated with GA crosslinked collagen type I, Group GR; SLA surface implants coated with collagen type I and crosslinked using 25 kGy of 60Co gamma radiation. New bone μCT volumes were obtained, and histologic and histometric analyses were performed in regions of interest. The GR group had significantly better new bone areas (NBAs) and bone to implant contact (BIC) results than the SLA group (p < 0.05), but the GA and GR groups were similar in this respect. New bone volumes and inter-thread bone densities (ITBD) were non-significantly different in the three groups (p > 0.05). Within the limits of this study, gamma-ray collagen crosslinking on titanium implants can be considered a substitute for glutaraldehyde crosslinking.