Bone marrow-derived mesenchymal stem cells (BMSCs) have been shown to promote the regeneration of injured peripheral nerves. Pulsed electromagnetic field (PEMF) reportedly promotes the proliferation and neuronal differentiation of BMSCs. Low-frequency PEMF can induce the neuronal differentiation of BMSCs in the absence of nerve growth factors. This study was designed to investigate the effects of low-frequency PEMF pretreatment on the proliferation and function of BMSCs and the effects of low-frequency PEMF pre-treated BMSCs on the regeneration of injured peripheral nerve using in vitro and in vivo experiments. In in vitro experiments, quantitative DNA analysis was performed to determine the proliferation of BMSCs, and reverse transcription-polymerase chain reaction was performed to detect S100 (Schwann cell marker), glial fibrillary acidic protein (astrocyte marker), and brain-derived neurotrophic factor and nerve growth factor (neurotrophic factors) mRNA expression. In the in vivo experiments, rat models of crush-injured mental nerve established using clamp method were randomly injected with low-frequency PEMF pretreated BMSCs, unpretreated BMSCs or PBS at the injury site (1 × 106 cells). DiI-labeled BMSCs injected at the injury site were counted under the fluorescence microscope to determine cell survival. One or two weeks after cell injection, functional recovery of the injured nerve was assessed using the sensory test with von Frey filaments. Two weeks after cell injection, axonal regeneration was evaluated using histomorphometric analysis and retrograde labeling of trigeminal ganglion neurons. In vitro experiment results revealed that low-frequency PEMF pretreated BMSCs proliferated faster and had greater mRNA expression of growth factors than unpretreated BMSCs. In vivo experiment results revealed that compared with injection of unpretreated BMSCs, injection of low-frequency PEMF pretreated BMSCs led to higher myelinated axon count and axon density and more DiI-labeled neurons in the trigeminal ganglia, contributing to rapider functional recovery of injured mental nerve. These findings suggest that low-frequency PEMF pretreatment is a promising approach to enhance the efficacy of cell therapy for peripheral nerve injury repair.
Magnesium (Mg) has the advantage of being resorbed in vivo, but its resorption rate is difficult to control. With uncontrolled resorption, Magnesium as a bone fixation material has minimal clinical value. During resorption not only is the strength rapidly weakened, but rapid formation of metabolite also occurs. In order to overcome these disadvantages, hydroxyapatite (HA) surface coating of pure magnesium plate was attempted in this study. Magnesium plates were inserted above the frontal bone of Sprague-Dawley rats in both the control group (Bare-Mg group) and the experimental group (HA-Mg group). The presence of inflammation, infection, hydrogen gas formation, wound dehiscence, and/or plate exposure was observed, blood tests were performed, and the resorption rate and tensile strength of the retrieved metal plates were measured. The HA-Mg group showed no gas formation or plate exposure until week 12. However, the Bare-Mg group showed consistent gas formation and plate exposure beginning in week 2. WBC (White Blood Cell), BUN (Blood Urea Nitrogen), Creatinine, and serum magnesium concentration levels were within normal range in both groups. AST (Aspartate Aminotransferase) and ALT (Alanine Aminotransferase) values, however, were above normal range in some animals of both groups. The HA-Mg group showed statistically significant advantage in resistance to degradation compared to the Bare-Mg group in weeks 2, 4, 6, 8, and 12. Degradation of HA-Mg plates proceeded after week 12. Coating magnesium plates with hydroxyapatite may be a viable method to maintain their strength long enough to allow bony healing and to control the resorption rate during the initial period.
17 October 2023 in Journal of Ultrasound in Medicine
Objective: The purpose of this clinical report was to introduce a new methodology for contour restoration of the over-resected mandible by reduction mandibuloplasty using 3-dimensional (3D) planning and computer-assisted design and manufacturing (CAD-CAM) custom-made titanium implants. Patient and method: A 20-year-old male patient had undergone reduction of the zygoma and mandibular angle and lower border for esthetic reason 1 year ago at a private clinic. However, he was not satisfied with surgical outcome and wanted to restore his original facial volume and contour. To assess the volume and dimension of resected bone, 3D-computed tomography (3D-CT) data at the original stage was superimposed with postsurgical CT. For restoration of the malar prominence, porous polyethylene malar implants with extensions into the lateral malar region (Medpor) were placed and fixed with microscrews. Custom-made titanium implants were fabricated for contour restoration of the mandibular angle and lower border using CAD-CAM technology (iDDA, Daegu, South Korea). Two-piece design per each titanium implant was adopted for easy placement and avoidance of tissue damage during placement. Thin buccal extension was incorporated for placement of screw holes. Location, direction, and length of bicortical screws were planned to avoid damage of the inferior alveolar nerve. Result: With the help of 3D planning and CAD-CAM technology, rigid fixation of the custom-made titanium implants into the mandibular angle and lower border successfully restored the contour of over-resected mandible to the original state. Conclusion: When over-resection by reduction mandibuloplasty becomes an issue, this method may be an effective treatment option for contour restoration of over-resected mandibular angle and lower border.