Shaofei Jiang

Dr. Shaofei Jiang

College of Civil Engineering, Fuzhou University, Fuzhou, China
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2006 in Advances in Structural Engineering
Verified
Journal Article
Closed access
SJShaofei Jiang
Shaofei Jiang
CZChun-Ming Zhang
Chun-Ming Zhang
CKC. G. Koh
C. G. Koh
Over the past two decades, multi-sensor data fusion method has attracted increasing attention to structural health monitoring due to its inherent capabilities in extracting information from different sources and integrating them into a consistent, accurate and intelligible data set. Meanwhile, since the probabilistic neural network (PNN) describes measurement data in a Bayesian probabilistic approach, it has been successfully applied to structural damage detection (Jiang et al. 2004; Klenke et al. 1996; Ko et al. 1999; Ni et al. 2001). In order to make full use of multi-sensor data (or information) from multi-resource and to improve the diagnosis accuracy of the health conditions for complex structures, it is advisable to combine these methods and exploit their individual advantages. In this paper, a 5-phase complex structural damage detection method by integrating data fusion and PNN is developed and implemented. The proposed method is then applied to damage detection and identification of two simulation examples. The result shows that the proposed method is feasible and effective for damage identification.

23 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
SJShaofei Jiang
Shaofei Jiang
ZQZehui Qiao
Zehui Qiao
NLNi-Lei Li
Ni-Lei Li
JLJian-Bin Luo
Jian-Bin Luo
Sheng ShenSheng Shen
Sheng Shen
YZYing Zhang
Ying Zhang
Due to the long-term service, Chinese ancient timber buildings show varying degrees of wear. Thus, structural health monitoring (SHM) for these cultural and historical treasures is desperately needed to evaluate the service status. Although there are some FBG sensing-based SHM systems, they are not suitable for Chinese ancient timber buildings due to the differences in architectural types, structural loads, materials, and environment. Besides, a technical gap in Fiber Bragg grating (FBG) sensing-based column inclination monitoring exists. To overcome these weaknesses, this paper develops an FBG sensing-based structural health monitoring system for Chinese ancient Chuan-dou-type timber buildings that aims at monitoring structural deformation, i.e., beam deflection and column inclination, temperature, humidity, and fire around the building. An in-situ test and simulation analyses were conducted to verify the effectiveness of the developed SHM system. To validate the long-term-operation of the developed SHM system, monitoring data within 15 months were analyzed. The results show good agreement between the developed SHM system in this paper and other methods. In addition, the SHM system operated well in the first year after its deployment. This implies that the developed SHM system is applicable and effective in the health state monitoring of Chinese ancient Chuan-dou-type timber buildings, laying a foundation for damage prognosis of such types of timber buildings.

19 June 2018 in Sensors
Verified
Journal Article
Open access
PDF file
NLNi-Lei Li
Ni-Lei Li
SJShaofei Jiang
Shaofei Jiang
MWMing-Hao Wu
Ming-Hao Wu
Sheng ShenSheng Shen
Sheng Shen
YZYing Zhang
Ying Zhang
The Fiber Bragg Grating (FBG) sensing technique is suitable for a wide variety of measurements, including temperature, pressure, acceleration, liquid level, etc., and has been applied to many bridges and buildings in the past two decades. The fact that the FBG technique can only monitor and measure strain data for most cases when it is used for deformation measurements impedes application of the FBG sensing technique in civil infrastructures. This paper proposes FBG sensing-based deformation monitoring methods that are applicable to monitoring beam deflection, column inclination angle and mortise-tenon joint dislocation for Chinese traditional timber structures. On the basis of improved conjugated beam theory and geometrical trigonometric function relationship, the relationships between the FBG sensing strain values and the deflection of beam, inclination angle of column, as well as the amount of dislocation of mortise-tenon joint are deducted for Chinese traditional buildings. A series of experiments were conducted to verify the applicability and effectiveness of the proposed deformation monitoring methods. The results show that a good agreement is obtained between the values given by the methods proposed in this paper and other methods. This implies that the proposed deformation monitoring methods are applicable and effective in the health monitoring of Chinese traditional timber structures.

4 January 2021 in Journal of Civil Structural Health Monitoring
Verified
Journal Article
Closed access
PDF file
ECErjiang Cui
Erjiang Cui
CZChunyuan Zuo
Chunyuan Zuo
MFMuning Fan
Muning Fan
SJShaofei Jiang
Shaofei Jiang

21 January 2019 in Materials
Verified
Journal Article
Open access
PDF file
SWshaofeng Wu
shaofeng Wu
SJShaofei Jiang
Shaofei Jiang
Sheng ShenSheng Shen
Sheng Shen
ZWZhao-qi Wu
Zhao-qi Wu
Anti-washout underwater concrete (AWC) is widely used in nondrainage strengthening; however, there still exist some problems with it, such as high strength loss and poor interfacial bond in practical engineering application. Based on the study of self-stressed concrete (SSC), a research on the mix ratio for the C30 self-stressed anti-washout underwater concrete (SSAWC) was carried out in this paper in hope of solving the above problems, specifically, by adding an expansive agent to the AWC. The parameters, such as strength, fluidity, anti-dispersity, and expansibility, were picked as target indices in determination of the mix ratio. The orthogonal test design and range analysis were used to determine the reasonable mix ratio and study the influence of various parameters on the performance of SSAWC. The experimental program conducted includes a series of strength, fluidity, anti-dispersity, and expansibility tests on 18 groups of specimens. The results show that C30 SSAWC has an excellent performance using the optimal mix ratio. Compared with AWC, the expansibility and self-stress of the SSAWC can be easily observed, and the compressive strength ratio of the SSAWC casted in water to that casted in air is much bigger. This implies that SSAWC is applicable to the nondrainage strengthening.

15 March 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ZWZhaoqi Wu
Zhaoqi Wu
YWYuan Wei
Yuan Wei
XWXintao Wang
Xintao Wang
CHChao Huang
Chao Huang
SJShaofei Jiang
Shaofei Jiang
Circular steel tube members with the absence of anticorrosive protection or coating failure are prone to uniform corrosion, which threatens the reliability and safety of members in the atmospheric environment. To fully study the mechanical behavior of uniformly corroded circular steel tubes, compression test and theoretical analysis were conducted, and two methods considering section reduction and material degradation, respectively, were adopted for the calculation of ultimate load carrying capacities of specimens. The results indicate that uniform corrosion did not change the failure modes of specimens, and all of them belonged to global buckling failure. The load carrying capacities and stiffness of specimens decreased with the increase of corrosion ratio, and the degree of reduction was greater than that of material degradation, showing a linear relationship with the corrosion rate. Under the same corrosion ratio, the specimens with larger eccentricity represented more obvious load carrying capacity and stiffness degradation. The load carrying capacities predicted by both methods were in good agreement with the test results and had a certain safety margin. The conservative degree of calculation results from three specifications followed a descending order of ANSI/AISC 360-16, GB 50017-2017, and EN 1993-1-1. Under the same corrosion ratio, the load carrying capacity variation of specimens between one-sided corrosion and two-sided corrosion was less than 3%.