Kainat Jahangir

Mrs. Kainat Jahangir


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 August 2025 in Fluids
Verified
Journal Article
Open access
PDF file
MAMuhammad Adnan Anwar
Muhammad Adnan Anwar
MRMudassar Razzaq
Mudassar Razzaq
MOMuhammad Owais
Muhammad Owais
KJKainat Jahangir
Kainat Jahangir
MGMarcel Gurris
Marcel Gurris
This study presents a numerical investigation into the heart valve through a fluid–structure interaction (FSI) framework using a two-dimensional, steady-state, Newtonian flow assumption. While simplified, this approach captures core biomechanical effects and provides a baseline for future extension toward non-Newtonian, pulsatile, and three-dimensional models. The analysis focuses on the influence of magnetic field intensity characterized by the Hartmann number (Ha) and flow regime defined by the Reynolds number (Re) on critical hemodynamic parameters, including wall shear stress (WSS), velocity profiles, and pressure gradients in the valve region. The results demonstrate that stronger magnetic fields significantly stabilize intravalvular flow by suppressing recirculation zones and reducing flow separation distal to valve constrictions, offering protective hemodynamic benefits and serving as a non-invasive method to modulate vascular behavior and reduce the risk of cardiovascular pathologies such as atherosclerosis and hypertension.

24 June 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
MAMuhammad Adnan Anwar
Muhammad Adnan Anwar
MRMudassar Razzaq
Mudassar Razzaq
MOMuhammad Owais
Muhammad Owais
KJKainat Jahangir
Kainat Jahangir
MGMarcel Gurris
Marcel Gurris
This study presents a numerical investigation into heart valve dynamics through a fluid–structure interaction (FSI) framework that incorporates biomagnetic blood flow and elastic arterial walls. The analysis focuses on the influence of magnetic field intensity—characterized by the Hartmann number (Ha)—and flow regime—defined by the Reynolds number (Re)—on critical hemodynamic parameters, including wall shear stress (WSS), velocity profiles, and pressure gradients in the valve region. Results demonstrate that stronger magnetic fields significantly stabilize intravalvular flow by suppressing recirculation zones and reducing flow separation distal to valve constrictions, offering protective hemodynamic benefits and serving as a non-invasive method to modulate vascular behavior and reduce the risk of cardiovascular pathologies such as atherosclerosis and hypertension.