This study details the design, fabrication, and experimental validation of a wearable, non-invasive microwave sensor for continuous blood glucose monitoring. It incorporates a crescent-loaded elliptical patch antenna with a complementary split-ring resonator (CSRR) tag unit to greatly improve sensing sensitivity. The sensor operates across multiple resonant frequencies, enabling broadband dielectric characterization of glucose-dependent blood permittivity. Incorporation of the CSRR tag unit leads to a marked improvement in electromagnetic coupling and field confinement, resulting in a substantial increase in sensitivity, achieving 1.14 MHz/mg/dL in resonant frequency shift and 0.015 dB/mg/dL in reflection coefficient sensitivity compared to conventional designs. The sensor was fabricated on an FR-4 substrate and experimentally characterized using a vector network analyzer (VNA), showing strong agreement between simulated and measured S11 responses, with minimal frequency deviations and consistent resonance behavior. Experimental results confirmed improved sensitivity in response to glucose concentration variations over the range of 0–500 mg/dL, validating the sensor’s performance under realistic conditions. Furthermore, a physics-informed deep learning (PI-DL) model was developed to predict glucose concentration directly from measured S11 data. The model achieved enhanced prediction accuracy, with a mean absolute error below 1 mg/dL and a strong generalization across unseen samples, demonstrating the power of combining physical modeling with data-driven approaches. These results confirm that the proposed sensor, enhanced with the CSRR tag unit and supported by a PI-DL framework, offers a promising pathway toward next-generation non-invasive, accurate, and wearable glucose monitoring solutions.
26 January 2026 in Wireless Personal Communications
This paper presents a high-sensitivity microwave sensor based on a modified Complementary Split Ring Resonator (CSRR) architecture, integrated with inductive stubs, for non-invasive blood glucose monitoring. The proposed sensor is designed to enhance the electric field localization and coupling efficiency by introducing inductive elements that strengthen the perturbation effect caused by glucose concentration changes in the blood. Numerical simulations were conducted using a multilayer finger model to evaluate the sensor’s performance under various glucose levels ranging from 0 to 500 mg/dL. The modified sensor exhibits dual-resonance characteristics and outperforms the conventional CSRR in both frequency and amplitude sensitivity. At an optimized stub gap of 2 mm, which effectively minimizes the capacitive coupling effect of the transmission line and thereby improves the quality factor, the sensor achieves a frequency shift sensitivity of 0.086 MHz/mg/dL and an amplitude sensitivity of 0.02 dB/mg/dL, compared to 0.032 MHz/mg/dL and 0.0116 dB/mg/dL observed in the standard CSRR structure. This confirms a significant enhancement in sensing performance and field confinement due to the optimized inductive loading. These results represent significant enhancements of approximately 168% and 72%, respectively. With its compact design, increased sensitivity, and potential for wearable implementation, the proposed sensor offers a promising platform for continuous, real-time, and non-invasive glucose monitoring in biomedical applications.